Warning
Description
Warning 100
Fan abnormal
Warning 103
NTC Broken
DSP and COM firmware
Warning 104
version unmatch
Warning 105
Over Temperature
Warning 106
SPD abnormal
Warning 107
NE abnormal
Warning 108
PV Circuit short
Warning 109
PV boost driver broken
Warning 110
String abnormal
U disk overcurrent
Warning 111
protection
Countercurrent prevention or
Warning 112
Reactive power dispatching
failure alarm
Notice:MAX series inverter has three external fans and one Internal fan.
If the suggestions do not work, please contact to Growatt.
9.2.2 Error
Errors codes identify a possible equipment failure, fault or incorrect inverter setting or
configuration, any or all attempts to correct or clear a fault must be performed by
qualified personnel.
Typically, the error code can be cleared once the cause or fault is removed.
Some of error code as table shows below, may indicate a fatal error and require you to
contact the supplier or Growatt for help.
57
Suggestion
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Check if the neutral and ground
cables are well connected and firm
Contact Growatt
Contact Growatt
Check if the polarity is `reversed or
short
Check if the USB port is connected
to a short circuit
Contact Growatt
Error Code
Description
Error 101
Communication error
Sample of main DSP and
Error 102
slave DSP are inconsistent
Error 106
PV CurrSample Fault
Error 107
AC CurrSample Fault
Error 108
SPS Power Fault
Error 110
Current over limit
Error 112
AFCI Fault
Error 113
IGBT drive fault
Error 114
AFCI Module check fail
Error 117
Relay fault
N - PE fault detection
Error 120
(PV - ground machine)
Error 121
CPLD abnormal
Error 122
Bus Fault
Error 124
No AC connection
Error 125
PV isolation low
Error 126
Leakage current too high
Error 127
Output DC current too high
Error 128
PV voltage high
Error 129
Grid voltage fault
Error 130
Grid frequency fault
Suggestion
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Contact Growatt
Check if the mains connection/mains
voltage and frequency are correct
Check panel and line insulation to
ground is good
Contact Growatt
Contact Growatt
Check PV actual voltage
Check the actual voltage and wiring of
the grid
Check the actual frequency of the grid