  • Page 1 ™ “Electrostatic” ULV/Mist Sprayer ’ ’...
  • Page 2 Thank you for purchasing our product. We take pride in the design, workmanship and service of all of our products. Designed by Curtis Dyna-Fog, Ltd. and marketed under our exclusive Aire-Mate line, this machine represents one of the highest quality and most innovative hand-held spraying products ever produced.
  • Page 3 Warranty Limited Warranty for Curtis Dyna-Fog Hand-Held Electric Models Curtis Dyna-Fog, Ltd. (“Seller”) warrants that the machines it sells will be free of defects in workmanship and material under normal use and service (as described in the operating manual) for a period of one year (12 months). Seller’s obligation under this Warranty is limited to...
  • Page 4: Table Of Contents

    Table of Contents Page Main Components Diagram……………………………………………………. 5 Safety Precautions……………………………………………………………… 6 Additional Safety Precautions…………………………………………. 7-8 DO’s and DONT’S………………………………………………………. 9-10 Specifications …………………………………………………………………… 11 Principles of Operation…………………………………………………………. 12 Flow Rates, Droplet Sizes and Applications…………………………………. 13-14 Insect Control……………………………………………………………. 13 Odor Control……………………………………………………………... 14 Disinfecting…………………………………………………………….… 14 Maintenance……………………………………………………………………..
  • Page 5: Main Components Diagram

    Main Components Diagram- Power and High Capacity Electrostatic Blower Indicator Light 3 Air Assist Nozzles Adjustable Locking Handle Electrostatic Charging Ring (Collector) Liquid Metering Valve Fill Cap Formulation Tank Hurricane ES Owner’s Manual...
  • Page 6: Safety Precautions

    Safety Precautions (It is the Operator’s responsibility to read and understand the Cautions and Warnings in this manual before attempting to operate the machine. Important: The Hurricane ES has been designed and engineered to be very safe during normal operation. As with all AC powered equipment, certain safety precautions should be taken. Please read the following WARNINGS before operating the machine.
  • Page 7 FIGURE 1 Safety Precautions (continued) This machine contains an electrostatic device that may interfere with sensitive medical devices such as pacemakers, defibrillators, or similar devices. DO NOT operate this machine or stand within 10 feet (3 meters) if you use any such medical devices. Contact your physician prior to operation if you are unsure if this machine will interfere with your medical device.
  • Page 8 California Warning: This machine contains lead, a chemical known to the State of California to cause cancer and birth defects, or other reproductive harm. DO NOT place your hands in your mouth after handling or use of the machine. DO NOT place any brass parts in your mouth. Wash your hands thoroughly after handling or using this machine Safety Precautions (continued) WARNING...
  • Page 9 formulation can ignite if the proper conditions exist. These conditions are basically two: 1) a sufficient volume of liquid in the form of fine particles suspended in the air; and 2) A sufficiently high energy source of ignition Safety Precautions (continued) 3.
  • Page 10 ▪ Ensure that formulation is applied only in strict compliance with the formulation label as well as local, state, and federal regulations. Safety Precautions (continued) DO NOT Do not spray flammable liquids near open flame or other source of ignition. Do not use oil-base or flammable formulations with this machine.
  • Page 11: Specifications

    SPECIFICATIONS Description: The Hurricane ES™ machine is an electrostatic “Cold Fog” ULV/Mister that utilizes a 3-nozzle air-assist design. This device is intended for applications of Water-Base formulations. The body and tank are made of high-density chemical resistant polyethylene. The applicator is useful for dispensing most chemicals which are labeled for aerosol or mist applications such as disinfectants, deodorizers, germicides, insecticides, etc., in locations such as hospitals, schools, nursing homes, greenhouses, stables, warehouses, homes, and farm buildings.
  • Page 12: Principles Of Operation

    Principles of Operation- This machine consists of a motor/blower assembly, high voltage power supply, charging ring and electrode, blower housing, a nozzle, formulation tank and metering valve. The blower is a two-stage centrifugal compressor driven by a universal motor operating at a speed of 20,000 rpm.
  • Page 13: Flow Rates, Droplet Sizes And Applications

    (Collector) FIGURE 4 Flow Rates, Droplet Sizes and Applications Liquid flow rate of the Hurricane ES is created by the suction caused by the design of the 3- nozzles. The Flow rate is regulated by adjusting the metering valve. The liquid flow rate can be increased by rotating the metering valve knob counterclockwise and decreased by rotating it clockwise.
  • Page 14: Odor Control

    optimal air born suspension and insect impaction. In dry climates evaporation will tend to cause droplets to “shrink”. Therefore it may be necessary to increase flow rate to get adequate coverage. The smaller the droplet size the greater the number of droplets that are created. For example: If 1 milliliter of spray is dispersed as 20 Micron droplets, there will be 239 million droplets produced.
  • Page 15: Maintenance

    Formulation Tube Valve Knob See Detail “A” Detail “A” Approximate flow rates for the valve position settings are as follows: FIGURE 5 Position Flow rate* Droplet Size (VMD) 6 oz/min (177 ml/min) 10-20 7.5 oz/min (222 ml/min) 20-30 9.5 oz/min (281 ml/min) 30-50 *Flow rates shown are approximate and will vary depending on liquid viscosity and temperature.
  • Page 16: Replacing The 3-Prong Electrode

    cord immediately. Always disconnect the main power cord before attempting to service the machine. If it becomes necessary to disassemble the Machine for cleaning, be careful not to damage the taper of the valve stem, as this will affect the flow positions/calibration of the machine.
  • Page 17 Steps for removing the metering valve and formulation filter 1) Using the 5/16 allen wrench provided with your Hurricane ES, loosen the set screw located in the knob assembly, and remove the knob assembly. 2) Using a flat blade screw driver, push the plastic drive rivet out of the formulation tank (See diagram “A”).
  • Page 18: Troubleshooting

    Troubleshooting Important: When dealing with any service or repair issue that requires accessing the inside of the blower housing, always have the machine serviced by a qualified factory representative. Call 317-896-2561 for a qualified service center near you. Symptom Possible Cause Corrective Action •...
  • Page 19: Electrical Schematic

    Electrical Schematic Diagram for 110V and 220V Hurricane ES Owner’s Manual...
  • Page 20: Hurricane Es Exploded Parts Diagram

    Hurricane ES Exploded Parts Diagram Hurricane ES Owner’s Manual...
  • Page 21 Hurricane ES Exploded Parts List Hurricane ES Owner’s Manual...
  • Page 22 ITEM PART NUMBER ITEM DESCRIPTION 62161 SCREW, 10 X ¾ HIGH-LOW THR. 62160 SCREW, 10-16 X 1.25 SHWH. 62124 FILTER, AIR 3.875 DIA. 62144-1 SPACER, PVC, MOTOR 62147-1 MOTOR, BLOWER AY.120V PANOSONIC 62147-2 MOTOR, BLOWER AY., 240V, PANASONIC 138530 WASHER,LOCK,#8,INTO, SST 65228 SCREW,6-32X1/2,PHCR,SST 62189-1...
  • Page 23 Hurricane ES Metering Valve Assemble (P/N: 62195) APPLY LUBRICANT TO THREADS AND O-RING Part Number Description Item 32692 Nut, Packing 32690 Washer, Packing 32691 Washer, Brass 62319-1 Stem, Metering Valve 62180 Valve Body, Brass 10100-110 O-Ring 62227-1 Tube, Blue, 3/16 ID. X 5/16 OD. 80408 Filter, Long tapered, 130 Microns Hurricane ES Owner’s Manual...
  • Page 24: Hurricane Es Carrying And Storage Bag

    10.0 Hurricane ES Carrying and Storage Bag Large pouch for storing extension cord, owner’s manual, tools, etc… P/N- 62188 Bag, Machine Carrying/Storage Hurricane ES Owner’s Manual...
  • Page 25 11.0 Hurricane ES Labels Label, Caution Label, (P/N:62197) Flow Caution (P/N:62194) Label, Shipping Carton (P/N:62193) Label, Warning, Read the Manual (P/N:62196) Label, Logo (P/N:62146) Label, Flow Rate Indicator (P/N:62198) Hurricane ES Owner’s Manual...
  • Page 26: Noise Level Comparison Chart

    Label, Warning, Electrostatic (P/N:62191) 12.0 NOISE LEVEL COMPARISON CHART choking, < HURRICANE ES Hurricane ES Owner’s Manual...
  • Page 27 Hurricane ES Owner’s Manual...
  • Page 28 Curtis Dyna-Fog, Ltd. PO Box 297 17335 US Hwy. 31 North Westfield, Indiana 46074 USA www.dynafog.com www.airemate.com Rev. Mar. 2012 Hurricane ES Owner’s Manual...