Chapter 1: Alarms
A004 – Bar Feeder Emergency Stop
BAR FEEDER
EMERGENCY STOP!
POSSIBLE CAUSES:
- EMERGENCY STOP
BUTTON PUSHED IN
- WIRING PROBLEM
Description:
The Bar Feeder Emergency Stop alarm occurs whenever the PLC does not detect input (I0.6). The problem is generated E-stop push
button on the remote control station is pressed in.
Solution:
Press the HELP key on the remote control station. Press the F4 (Page Down icon) twice.
Case
Input
Remote Pendant
1
Bit 6 = 1
2
Bit 6 = 0
For case 2, after the solution has been completed, press the STOP key on the remote control station to clear the message and reset
the alarm.
A004
MODULE 0
Alarm needs to be cleared. Press the STOP key on the
76543210
remote control station to clear the message and reset
the alarm.
1000000
MODULE 0
Reset the E-stop push button on the remote control
76543210
station.
0
Solution
QUICK LOAD SERVO S3
1 - 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QUICK LOAD SERVO S3 and is the answer not in the manual?

Questions and answers

tom,
March 18, 2025

LNS BARFEEDER sps no response , how do i fix this error

1 comments:
Mr. Anderson
March 18, 2025

The SPS No Response alarm on the QUICK LOAD SERVO S3 occurs due to a communication problem between the remote control station and the LNS PLC. To fix this error:

1. Check the connectors between the PLC and the remote control station inside the cross piece to ensure they are correctly attached.
2. Verify continuity between the PLC and the remote control station.

These steps help restore proper communication and resolve the error.

This answer is automatically generated

Table of Contents

Save PDF