Set Dipswitch; Initial Power Up; Figure 15. Setting Dipswitch - CZone Control 1 User And Installation Manual

Table of Contents

Advertisement

SET DIPSWITCH

Using a small screwdriver carefully set the dipswitch on the Control 1. The dipswitch number must be unique
for all modules on the CZone network and must match the dipswitch setting in the configuration to function
correctly. The example in Figure 12 shows a dipswitch number of 01101100 where 0 = Off and 1 = On

INITIAL POWER UP

1. Check all plugs are securely seated and connections are tight.
2. Ensure the Control 1's top cover is clipped securely in place and gasket is seated properly around fuses.
3. Power up the NMEA2000 network.
4. Check that the NMEA2000 Network LED lights up. It may also be flashing if other devices are present and
transmitting data.
5. Turn the switch/circuit breaker on supplying the Control 1's main positive stud.
6. Check that the Power indicator LED is green.
7. Check the circuit's status LED's for each individual circuit. Refer to LED codes to diagnose any faults which
need to be rectified.
8. Check the software version on the Control 1 with the CZone Configuration Tool and update if necessary.
9. Write configuration file to the Control 1 and the rest of the CZone modules on the system (Refer to the CZone
Configuration Tool Instructions for details on how to configure the Control 1).
10. Test all inputs and outputs for configured functionality.
Figure 12. Setting Dipswitch