To perform a power reset on the Tidel TACC-IIa, either remove and reinsert the fuse or unplug and replug the AC power cord. After doing so, all LEDs should illuminate momentarily as part of the LED test.
Table Of Contents Component Location ..........2 Loading the Operating Cash: ........3 Checking the number of tubes ........4 Making Drops ............4 Vending Operations: ..........5 Activate the Alternate Vend Delay Timer ....6 Door Opening Procedures ........... 7 Notes on Door Opening ..........
LOADING THE OPERATING CASH Each one of the 8 columns will hold: 12 tubes – Serial numbers beginning with A91, A92 or A93. 11 tubes – Serial numbers beginning with IA. Step 1: All coins should be wrapped. Do not place tape over the end of the tube.
CHECKING THE NUMBER OF TUBES IN THE TACC-IIa Step 1: Insert the dipstick into the tube loading hole with the highest number first. Step 2: The number at bottom of tube loading hole is the number of tubes in the magazine.
VENDING OPERATIONS The Vending Key is located on the Control Panel. When the Vending Key is OFF: The wait light will remain on. No tube can be vended. The time delay continues to advance. If the key is turned back to the ON position and the time delay was achieved while the key was OFF, the READY light will illuminate and a vend is possible.
TO ACTIVATE THE 30 SECOND ALTERNATE VEND DELAY TIMER The “Alternate Vend” feature allows the operator to change the vend delay time from 2 minutes to 30 seconds (for peak activity periods). To activate the 30 second Alternate Vend feature: Step 1: Turn the Manager Key ON and release it.
DOOR OPENING PROCEDURES Overflow from the cash register is deposited in the drop chutes on left and right sides of the unit. A divider is placed in the bottom of the unit to separate the 2 sides. To retrieve items deposited into the drop chutes, the door must be opened.
NOTES ON DOOR OPENING If the door is opened without waiting the door opening delay time or if power is disconnected from the unit while the door is open, the WAIT light will illuminate and no vends will be possible. To activate the vending functions again, turn the Manager Key and release it.
TO OPEN THE DOOR (INSTANT ACCESS) Step 1: Turn the Instant Access (Courier), key and release it, (the Courier key is spring loaded and should return to the off position). The DOOR light will illuminate. Step 2: Within 10 minutes, turn the Door Bolt Key and open the door.
DUMPING TUBES FROM THE MAGAZINE Step 1: The door must be opened and the READY light must be illuminated to dump tubes. If the door is open, but the READY light is not illuminated: a) Insure the Vending Key is in the ON position. b) Turn the Manager Key to the ON position and release it.
1) Perform a power reset and verify all lights on the Control Panel illuminate for a moment. 2) Later TACC-IIa models require you press the “DOOR” button within 30 seconds after the Manager Keyswitch is turned to start the door timer. Earlier models required turning the Manager Keyswitch only to start the door timer.
Page 14
DOOR BOLT EXTENDED WITH DOOR OPEN 1) The solenoid must be activated to allow the Door Bolt Key to be turned: a) On early production Tacc-IIa’s, press the “DOOR” button on the Control Panel and within 30 seconds, turn the Door Bolt Key.
Page 15
3) If the DOOR button on the Control Panel is pressed 3 times during the time delay, the door timer will be aborted. 4) Check for a dedicated circuit or a Tidel approved surge protec- tor. TIME DELAY (2 MIN) APPLIES TO VENDING TUBES WHEN DOOR IS OPEN 1) Possible door sensor popped out of it’s bracket or defective.
Page 16
WILL NOT VEND 1 COLUMN, MOTOR OPERATES, NO TUBE DROPS 1) Probable obstruction in magazine. With the door open, press the vend button for the column which will not vend. When the vend motor begins to run, disconnect AC power from the unit. This action should stop the cradle in a half open position.