Interface Controller Switch Setting - Mitsubishi Electric PUHZ-W50VHA Technical Manual

Air to water (atw) heat pump, interface (i/f) and flow temp. controller (ftc)
Hide thumbs Also See for PUHZ-W50VHA:
Table of Contents

Advertisement

<Thermistor Characteristic graph>
Target temperature thermistor (TH1)
Thermistor for
lower temperature
Pipe temperature thermistor/liquid (TH2)
Pipe temperature thermistor / 2-phase (TH5)
Thermistor R0 =15k" ± 3%
Fixed number of B =3480 ± 2%
1
Rt =15exp { 3480 (
273+t
0:
15k"
10:
9.6k"
20:
6.3k"
25:
5.4k"
30:
4.3k'
40:
3.0k"

5. Interface controller switch setting

Set the switches following the system specifi cations below.
Switch1. Switch6 : Input selection of inverter capacity setting
Input
REMOTE SWITCH
Type A (4bit-8 setting)
REMOTE SWITCH
Type B (1bit-1 setting)
4-20mA
1-5V
0-10V
0-10kΩ
No input (AUTO mode)
SW1-4~8 : OFF fi xed (Initial setting)
• SW2-1/2-2 : Fixed operation mode
SW2-1
SW2-2
Details
OFF
OFF
Not FIX (Depending on Remote controller setting)
ON
OFF
[Cooling]FIX
OFF
ON
[Heating]FIX
ON
ON
External input(Depending on TB142-3,4)
• SW2-3/2-4/2-5 : Fixed set temperature [For Auto step mode only]
SW2-3
SW2-4
SW2-5
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
Set switches in case of auto step mode.
SW2-6 : Setting of TH5
When TH5 (2-phase pipe temp. thermistor) is connected, it is necessary to set the Dip SW2-6 of the interface controller.
SW2-6
Details
OFF
Connect TH5
ON
Not connect TH5 (Initial setting)
SW2-7, 8 : OFF fi xed (Initial setting)
SW3 : LED2~5 display setting (Refer to 8.)
1
) }
273
SW 1-1
SW 1-2
SW 1-3
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
Details
Not fi xed (Remote controller setting)
Cooling 19 ˚C /Heating 17 ˚C FIX
20 ˚C FIX
22 ˚C FIX
24 ˚C FIX
26 ˚C FIX
28 ˚C FIX
Cooling 30 ˚C / Heating 28 ˚C FIX
50
40
30
20
10
SW 6-1
SW 6-2
Step for capacity setting
OFF
OFF
OFF/Step1/Step2/.../Step7/Auto step
OFF
OFF
OFF/Step1/Step4/Step7/Auto step
ON
ON
OFF/Step1/Step2/.../Step7
OFF
ON
OFF/Step1/Step2/.../Step7
OFF
OFF
OFF/Step1/Step2/.../Step7
OFF
OFF
OFF/Step1/Step2/.../Step7/Auto step
OFF
OFF
Only Auto step mode
31
< Thermistor for lower temperature >
0
-20 -10 0
10 20 30 40 50
Temperature ( )

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents