  • Page 1 Upper arm blood pressure monitor Please read carefully! Instruction Manual Art. 48681...
  • Page 2: Table Of Contents

    GB Instruction Manual 1 Safety Information ......1 2 Useful Information ......3 3 Getting started .
  • Page 3 Device and controls Upper arm cuff with hose START button Display MEMORY button TIMER button Socket for mains adaptor Connector for the hose DC 6V...
  • Page 5: Safety Information

    1 Safety Information IMPORTANT INFORMATION! RETAIN FOR FUTURE USE! Read the instruction manual carefully before using this device, especially the safety instructions, and keep the instruction manual for future use. Should you give this device to another person, it is vital that you also pass on these instructions for use.
  • Page 6 • Protect the unit from moisture. Should moisture enter the unit, remove the batteries and stop using it immediately. In this case, please contact either your dealer or MEDISANA directly. You can find details of how to contact us on the address page.
  • Page 7: Useful Information

    2.3 How is blood pressure measured? The MTP is a blood pressure unit which is used to measure blood pressure at the upper arm. The measurement is carried out by a microprocessor, which, via a pressure sensor, measures the vibrations resulting from the inflation and deflation...
  • Page 8 2 Useful Information 2.4 Why should you take your blood pressure at home? MEDISANA has had many years of experience in the field of blood pressure measurement. The high precision of MEDISANA devices has been confirmed by extensive clinical tests, carried out according to strict international standards. One strong argument in favour of taking blood pressure at home is the fact that the readings are taken in familiar surroundings under relaxed conditions.
  • Page 9: Getting Started

    2 Useful Information / 3 Getting Started 2.6 Fluctuations in blood pressure There are many factors that can influence blood pressure. Readings can be affected seriously by stress, fear, heavy physical exertion or the time of day at which the measurements are taken.
  • Page 10 3.2 Using a Mains Adaptor Alternatively, you can use the unit with a special mains adaptor (MEDISANA Art.–No. 51036) This connects to the socket provided at the back of the unit.
  • Page 11: Operation

    Press the MEMORY button to change the values. 3.4 Setting up the user memory The MTP gives you the opportunity to assign readings to one of two user memories, each of which provides 99 memory slots. Press and hold the TIMER button for several seconds.
  • Page 12: Memory

    4 Operation / 5 Memory 4.3 Taking blood pressure readings a. Press the START button • All the display symbols will appear for approx. two seconds. • The cuff will then inflate. The increasing pressure is displayed numerically. • Pressing the START button during inflation will stop the inflation process.
  • Page 13: Miscellaneous

    Repeat the measurement under relaxed conditions, following the instructions exactly. If the same error occurs repeatedly with further readings, please contact MEDISANA. ERR 5 An average value could not be calculated due to unstable conditions while the readings were being taken.
  • Page 14 EN 1060-4 and according to the AAMI – Standard (US). Electromagnetic compatibility: The device complies with the EN 60601-1-2 standard for electromagnetic com- patibility. Inquire at MEDISANA for details on this measurement data. Intended use: This unit is suitable for non-invasive blood pressure measurement in adults (i.e.,...
  • Page 15 6 Miscellaneous 6.6 Technical specifications Name and model : MEDISANA Blood pressure monitor MTP Display system : Digital display Memory slots : 2 x 99 Measuring method : Oscillometric Voltage supply : 6 V=, 4 x 1.5V battery AA LR6 Measuring range blood pressure : 30 –...
  • Page 16: Warranty

    The following warranty terms apply: 1. The warranty period for MEDISANA products is three years from date of purchase. In case of a warranty claim, the date of purchase has to be proven by means of the sales receipt or invoice.