Mitsubishi Electric MELIPC MI5000 Series Programming Manual page 19

Vxworks
Hide thumbs Also See for MELIPC MI5000 Series:
Table of Contents

Advertisement

■Remote operation and model name reading
The following table shows the station numbers to be specified during remote operation and model name reading.
Communication route
Own station address
CC-Link IE Field Network
Specification of station numbers of other stations
Specify a station number using the following format.
Upper/lower
Setting item
High byte
Network No.
Low byte
Station number, group number, or all
stations
• Logical station number setting method
Set '0' in the upper byte (network number) of the station number above, and specify a logical station number in the lower byte
(station number).
The setting range of the logical station number is 65 to 239 (41H to EFH). Set the logical station number with the user program
(MELSEC data link functions).
Target functions
Page 100 mdControl
Page 113 mdTypeRead
Device type
For the device types to be specified by the MELSEC data link functions, either a code or a device name can be specified.
Device names are defined in the include files (MDFunc.h).
Device name (device)
Input relay (X)
Output relay (Y)
Latch relay (L)
Internal relay (M)
Special relay (SM)
CPU buffer memory (CPU No. 1 area)(U3E0/G)
CPU buffer memory (CPU No. 2 area)(U3E1/G)
CPU buffer memory (CPU No. 3 area)(U3E2/G)
CPU buffer memory (CPU No. 4 area)(U3E3/G)
Fixed cycle communication area (CPU No. 1 area) (U3E0/HG)
Fixed cycle communication area (CPU No. 2 area) (U3E1/HG)
Fixed cycle communication area (CPU No. 3 area) (U3E2/HG)
Fixed cycle communication area (CPU No. 4 area) (U3E3/HG)
Annunciator (F)
Timer contact (T)
Long timer contact (LT)
Timer coil (T)
Long timer coil (LT)
Counter contact (C)
Long counter contact (LC)
Counter coil (C)
Long counter coil (LC)
Timer current value (T)
Long timer current value (LT)
Counter current value (C)
Specification method
Own station
Own station
Other station
1 to 239 (1H to
EFH)
0 to 120 (1H to 78H)
Code
Decimal
1
2
3
4
5
501
502
503
504
511
512
513
514
6
7
41
8
42
9
44
10
45
11
43
12
Station number
255(FFH)
255(FFH)
Refer to the following chart
Description
Set this to specify other stations in the own network or each station on other
networks. (Use to perform request-to-send to the CC-Link IE field network. )
Set the station number of other stations.
For CC-Link IE Field Network, the setting range is from 0 to 120.
Hexadecimal
1H
2H
3H
4H
5H
1F5H
1F6H
1F7H
1F8H
1FFH
200H
201H
202H
6H
7H
29H
8H
2AH
9H
2CH
AH
2DH
BH
2BH
CH
1.2 MELSEC Data Link Functions
Device name specification
DevX
DevY
DevL
DevM
DevSM
DevSPB1
DevSPB2
DevSPB3
DevSPB4
DevHSPB1
DevHSPB2
DevHSPB3
DevHSPB4
DevF
DevTT
DevLTT
DevTC
DevLTC
DevCT
DevLCT
DevCC
DevLCC
DevTN
DevLTN
DevCN
1 PROGRAMMING