Error code
Description
Decimal
Hexadec
imal
■Setting data size error
-296
FED8H
The setting data size is out of range.
-328
FEB8H
■Group number error
The specified group number is out of range.
■Link time specification error
-329
FEB7H
The specified link scan time is out of range.
-330
FEB6H
■Number of detections of disconnected slave stations
specification error
The specified number of detections of disconnected slave
stations is out of range.
■CC-Link IE Field Network Basic parameter unset
-331
FEB5H
The function was executed without setting CC-Link IE Field
Network Basic parameters.
-332
FEB4H
■Slave station timeout time specification range error
■Link scan data assurance wait time timed out
-335
FEB1H
The specified data assurance wait time is elapsed.
-336
FEB0H
■Slave station number specification error
The specified slave station number does not exist in the
slave station.
■Data assurance ended error
-361
FE97H
Ending of data assurance was attempted when data
assurance was not being performed.
-362
FE96H
■CC-Link IE Field Network hardware error
Data assurance of the CC-Link IE field network cannot be
started due to a hardware error.
■Event number specification error
-366
FE92H
The specified event number is out of range.
-367
FE91H
■Data assurance start timeout error
A timeout occurred at the start of data assurance.
■Data assurance setting error
-368
FE90H
There was an attempt to start data assurance when
"Station-based Block Data Assurance" was "Disable" in the
parameters of the CC-Link IE Field Network.
-369
FE8FH
■Data link error
Starting of data assurance was attempted when there was
no data linking.
■Data assurance running error
-371
FE8DH
Starting of data assurance was attempted when data
assurance was already being performed.
-372
FE8CH
■Timeout value invalid
The specified timeout value is out of range for the OS
linking function.
■Timeout error
-373
FE8BH
A timeout occurred during inter OS shared semaphore
acquisition.
-374
FE8AH
■Windows part forced restart not permitted
There was an attempt by a C Controller module dedicated
function to perform a Windows part forced restart when the
"Windows part forced restart" setting in Basic parameters
was "Disable".
■Shared memory access error
-375
FE89H
Access of the shared memory of the OS linking function has
failed.
-376
FE88H
■Inter OS event notification error
Notification of an inter-OS event of the OS linking function
has failed.
■Data assurance running by other task error
-377
FE87H
Ending of data assurance was attempted when data
assurance was being performed by another task.
Corrective action
Check the setting data size.
Check the specified group number.
Check the specified link scan time.
Check the specified number of detections of disconnected slave
stations.
Set the CC-Link IE Field Network Basic parameters with MI
Configurator.
Check the timeout time for the disconnection detection of the
specified slave station.
Increase the timeout time specified to the argument.
Check the specified slave station number.
Make sure that data assurance is ended only when the user program
is performing data assurance.
• Check if the MELIPC is running normally.
• Reset the MELIPC.
• Retry.
Check the specified event number.
• Increase the timeout time of the argument to be specified by the
user program.
• Retry.
In the parameter of the CC-Link IE Field Network, change the setting
in "Station-based Block Data Assurance" to "Enable".
Restart the date link.
Make sure that data assurance is not started in two instances by the
user program.
Check the specified timeout value.
Consider the synchronization, or the time required for processing by
a target under exclusive control, and then set a sufficiently long
timeout value.
Configure "Enable" for the "Windows part forced restart" setting in
the Basic parameters.
• Check if the MELIPC is running normally.
• Reset the MELIPC.
• Retry.
• Check if the MELIPC is running normally.
• Reset the MELIPC.
• Retry.
Revise the user program so that the same task starts and ends data
assurance.
Appendix 1 Function error codes