INSTALLATION
1
Characteristics:
80 mm
2
Installation:
Installation allowed only by authorized electrician.
Before connecting the unit, read the instructions carefully.
Cabling
DOWN :
IB BUS line
UP :
Common :
C
N
LT motor
PE
Phase
SUPPLY
Neutral
230V 50Hz
Earth
inteo
The CENTRALIS UNO IB VB is an individual control of AC motor with link to master control.
The CENTRALIS UNO IB VB is dedicated to exterior venetian blind application.
• Compatibility with the SOMFY "IB" BUS line (common = +V).
• Integrated switch to disable the master commands.
• Possibility to set an intermediate oriented position.
80 mm
33 mm 17 mm
UP
DOWN
+
N
N
L
CENTRALIS UNO IB VB
• Main supply : 220-240V 50Hz.
• Class II product
• Protection index IP40.
• Output : 250V~ 3A cosφ 0,8.
• Output temporisation : momentary or fixed
• Environmental conditions for use :
- temperature +5°C to +40°C (no condensation allowed).
- pollution degree typical for usual living space.
Respect the electrical standards in force as well as the following points:
- disconnect the mains before carrying out any work.
- ensure that no forces act on the screw terminals after installation.
- Do not forget to mount the protection cover to separate the cables for the
BUS line and the cables for the power supply.
®
guide
EN60730-1
EN50081-1
EN50082-1
(activ for 180s).

Advertisement

loading
Need help?

Need help?

Do you have a question about the inteo CENTRALIS UNO IB VB and is the answer not in the manual?

Questions and answers

Summary of Contents for SOMFY inteo CENTRALIS UNO IB VB

  • Page 1 The CENTRALIS UNO IB VB is an individual control of AC motor with link to master control. The CENTRALIS UNO IB VB is dedicated to exterior venetian blind application. • Compatibility with the SOMFY “IB” BUS line (common = +V). • Integrated switch to disable the master commands.
  • Page 2 Mounting PROTECTION COVER FRONT PLATE CONTROL UNIT FRAME BRACKET Do not forget to mount the protection cover to separate the BUS line and the power supply. WALL Using: Operating mode The CENTRALIS uno IB VB offers two different operating modes. You can visualise the selected mode at the power on of the CENTRALIS uno IB VB.
  • Page 3 Intermediate position / automatic slats tilting With the CENTRALIS uno IB VB, it is possible to program an intermediate position (IP) and an automatic opening of the slats at this position. Principle : the CENTRALIS uno IB VB records the timing for the venetian blind to go from the starting position to the interme- diate position you wish to program.