A
Appendix
A.1
U.K. Accessories: PAW-G3KITL
Please check and follow local regulations!
For the United Kingdom, please follow the Water Supply Water Fitting Regulation, WRAS
requirements. For use with PAW-VP1000LDHW-1 or PAW-VP750LDHW-1 the optional PAW-
G3KITL may be utilised to fulfil the local regulation.
Components supplied with the unit in a separate accessory kit* (PAW-G3KITL) for site fitting:
● Multiblock valve, includes pressure reducing valve, line strainer, balanced cold
● Tundish - 1 1/4" × 1 1/2"
● 22mm x 1" Elbow / Drain Cock
● Motorised valve
● Expansion vessel.
* Only valid for UK can be ordered separately if required
Installation example
City water inlet
B
DHW PAW-VP - Installation manual – 2020-05
water take off, (for shower or bidet only) check and expansion valve.
A
D
E
"Temperature and pressure relief valve" is factory fitted for tank
C
versions PAW-VP1000LDHW-1 or PAW-VP750LDHW-1
C
Pressure reducing valve
Multiblock (2.1 bar) includes
A
Expansion valve (8 bar)
Expansion vessel
B
Temperature and pressure
C
relief valve
Tundish
D
Elbow / Drain cock
E
Appendix