M PAW-VP1000LDHW; PAW-VP750LDHW – U-250PE2E8A (PACi
R410A)
Indoor Unit Tank detailed settings; Remote controller CZ-RTC5B
Parameter
"DN" code
10
11
06
0b
0C
0d
15
16
21
22
28
2C
2d
i
Note
"DN" codes 10 & 11 must be set first.
Outdoor unit detailed settings by CZ-RTC2/4*
Parameter
"DN" code
7
1d
20
21
4b
A5
* to be purchased separately
DHW PAW-VP - Installation manual – 2020-05
Default
New value
Explanation
value
to set
0006
0033
Unit Type
0015
0023
Capacity code
Inlet temperature shift in heating mode.
0004
0000
non-active
0002
0000
EXCT setting
0000
0001
Heating preparation display
0000
0001
Cool/ Heat auto non-active
0022
0022
0000
0000
Fan speed not displayed
0030
0055
Heating upper limit 55°C
0018
0035
Heating lower limit 35°C
Automatic restart after power failure
0001
0001
activated
0000
0006
Expansion valve setting
0008
0008
Operation mode DHW
Default
New value
Explanation
value
to set
000
001
Specific tank setting
-001
070
Demand Level
-015
-035
Th. Off differential change from 1.5 k to 3.5 k
000
600
Thermostat off judgement time (600 sec.)
000
001
Specific tank setting
000
-004
Frost adherence temperature