ED900 Installation Instructions – Single door Table of Contents Table of contents Table of contents ED900 installation overview General information 12.1 Installation preparation ED900 installation templates General information ED900 Arm configurations 13.2 Installation templates – pull arm Product description 13.3...
Page 3
ED900 Installation Instructions – Single door Table of Contents Measure door width, reveal depth ANSI/BHMA standards 18.1 Door width parameter Tb 30.1 A156.19 Low energy power operated doors Upgrade cards 18.2 Record door width measurement, Tb value 18.3 Tb parameter values 31.1...
1.1.1 Installation Instructions 1.1.6 Symbols used in these instructions. This manual provides installation instructions for WARNING ED900 low energy swing door operators used in single door installations. This symbol warns of hazards which could result in personal injury or threat to health.
Reference Para. 6.2, Operating specifications. used exclusively for opening and closing interior swing doors. 2.1.4 Hardware as shipped, single swing door. The ED900 operator must be installed on an interior Reference Chapter 5 for ED900 hardware overview. building surface. Fig. 2.1.1 ED900 operator 2.1.2 Low energy operator.
Proper signs and labels, per ANSI/BHMA A156.19 Crushing hazards at door closing edges! Standard for Power Assist and Low Energy Power Operated Doors, shall be applied and maintained on the door controlled by the ED900 swing door operator. Fig. 3.1 Door closing edges •...
End cap, power switch Mounting plate 115 Vac terminal block Spindle cap Spindle cap ED900 pull arm system Fig. 4.2.1 ED900 RH pull arm system example ED900 operator T/track/arm assembly Axle extension Standard cover End cap, program switch End cap, power...
ED900 Installation Instructions – Single door Chapter 5 ED900 full width cover kit – option 5.9.1 Full width cover kit. Single door, from 29" [737] to 48" [1219]. Fig. 5.9.1 Full width cover kit 08125259 Fine cover single 08120350...
ED900 Installation Instructions – Single door Chapter 5 5.10 Key switch panels – option Fig. 5.10.2 Communication cable Fig. 5.10.1 Key switch panels Key switch panel, with RJ45 Key switch panel Communication cable for program switch panel comm port...
ED900 Installation Instructions – Single door Chapter 6 6 Technical data ED900 Technical data 6.1.4 Outputs Maximum wire size 6.1.1 Required operating conditions. 16 AWG Connector plug 1/16” screw size Ambient temperature 5 to 122 °F Sr parameter Suitable for dry...
Chapter 19; Parameters. door in closed position. Low energy product 7.2.1 ANSI/BHMA 156.19. ED900 operator is configured to meet requirements of a low energy application per ANSI/BHMA A156.19, U.S. Standard for Power Assist and Low Energy Power Operated Doors. 7.2.2 Low energy power operated door.
ED900 Installation Instructions – Single door Chapter 8 Program and Exit Only switches 8.3.1 Program switch control modes. • Auto, door opens following pulse • Open, door opens automatically and generation by a knowing act device or remains open.
ED900 Installation Instructions – Single door Chapter 9 9 System accessories System accessory electrical connections Fig. 9.1.1 Electrical connections, single door External program 3 x 12 AWG switch, mechanical 115 VAC power 3 x 4.0 mm External program switch, electronic...
ED900 Installation Instructions – Single door Chapter 9 ED900 terminal board interfaces Fig. 9.3.1 Terminal board electrical connections Green LED (Para. 8.4) Night- Activation inputs Yellow LED (Para. 8.4) Interior Exterior bank Safety sensors Red LED (Para. 8.4) input...
ED900 Installation Instructions – Single door Chapter 10 10 ED900 door signage 10.1 Low energy operator 10.1.1 Overview Fig. 10.1.1 AUTOMATIC CAUTION DOOR decal Signage and warnings are specified in ANSI /BHMA A156.19, American National Standard for power assist AUTOMATIC and low energy power operated doors.
ED900 Installation Instructions – Single door Chapter 10 10.3 Safety Information label, low Fig. 10.3.1 Safety Fig. 10.3.2 Annual information compliance energy swing doors label inspection label 10.3.1 Low energy swinging door safety information ANNUAL COMPLIANCE SAFETY INFORMATION label.
Doors. 12.1.6 ED900 115 Vac electrical installation. 12.1.1 dormakaba USA, Inc. ED900 hardware. WARNING 1. Locate shipping boxes for ED900 operator and Work on electrical equipment and 115 Vac hardware. wiring installation must be performed only by 12.1.2 Door frame and door.
ED900 Installation Instructions – Single door Chapter 13 13 ED900 installation templates 13.2 Installation templates – pull arm Fig. 13.2.1 Assembly on hinge side, pull version with slide channel and long pivot pin 5 7/8” [150] 4 3/16” [106] 3 15/16”...
Page 29
ED900 Installation Instructions – Single door Chapter 13 Fig. 13.2.2 Assembly on hinge side, pull version with slide channel CPD and short pivot pin 5 7/8” [150] 4 3/16” [106] 4 3/4” 4 3/4” 4 3/4” 3 3/4” 3 15/16”...
Page 30
ED900 Installation Instructions – Single door Chapter 13 Fig. 13.2.3 Assembly on hinge side, pull version with slide channel CPD and long pivot pin 5 7/8” [150] 4 3/16” [106] 3 15/16” 4 3/4” 4 3/4” 4 3/4” 3 3/4”...
ED900 Installation Instructions – Single door Chapter 13 13.3 Installation templates – pull as push Fig. 13.3.1 Assembly on opposite hinge side, push version with slide channel and short pivot pin 5 7/8” [150] 4 3/16” [106] 3 3/4”...
1. Remove 115 Vac plug (5) from its 115 Vac socket receptacle (6). 14.1.2 Remove mounting plate from ED900 operator. 1. Loosen all eight captive ED900 M6 socket head cap screws (SHCS) using a 5 mm hex T-handle. TIPS AND RECOMMENDATIONS Insure all eight fasteners are free of the mounting plate.
Page 35
ED900 Installation Instructions – Single door Chapter 14 Fig. 14.1.3 Mounting plate removal Fig. 14.1.4 5 mm T-handle hex key Guide pin ED900 08125310 02-2020...
Page 36
ED900 Installation Instructions – Single door Chapter 14 14.2 Options – Customer 115 Vac connection to terminal blocks Fig. 14.2.1 115 Vac terminal block WARNING 115 VAC terminal block Work on electrical equipment and Ground terminal 115 Vac wiring installation must...
Page 37
ED900 Installation Instructions – Single door Chapter 14 Fig. 14.2.5 115 Vac terminal block mounting 14.2.3 Install conduit box (option). 115 VAC terminal block TIPS AND RECOMMENDATIONS Ground terminal 115 Vac terminal block is secured M3.5 screw to mounting plate by M3 x 25 115 Vac plug to Phillips head screw.
ED900 Installation Instructions – Single door Chapter 15 15.2 Connect customer 115 Vac to ED900 mounting plate terminal block Fig. 15.2.1 115 Vac wiring example 15.2.1 Connect customer 115 Vac wiring. 115 Vac terminal block Ground post WARNING Work on electrical equipment and...
Page 40
15.5 Install ED900 operator onto mounting plate 15.5.1 Install ED900 operator onto Fig. 15.5.1 Installation of ED900 on mounting plate mounting plate. CAUTION Protective film strip removal. Insure two protective film strips have been removed from operator heat conductive pads (Para.
Page 41
ED900 Installation Instructions – Single door Chapter 15 15.6 Full width cover (option) installation instructions Fig. 15.6.1 Mounting plate 15.6.1 Install ED900 mounting plate. Mounting plate installation: • Reference Chapter 13 for installation templates. 15.6.2 Secure mounting plate extension to door frame and/or wall.
Page 42
DC3481-010 Once ED900 operator is installed, Program switch kit program switch wires will be DC3482-010 connected to terminal board (Fig. 15.6.10). Fig. 15.6.9 ED900 installation with mounting plate extension Professional cover bracket DC3481-010 Program switch kit DC3482-010 Program switch Fig. 15.6.10 ED900 program switch wiring...
ED900 Installation Instructions – Single door Chapter 16 16 J/Push arm installation 16.1 Push arm installation templates NOTICE Reference Chapter 13 for push arm installation templates. Fig. 16.1.1 Push arm assemblies J8/Standard push arm, reveal depths 0 - 8" maximum...
Page 44
Fig. 16.2.5 Push arm assemblies for installation Reference Chapter 19, Operator spring tension. 2. Insert axle extension into drive arm. 3. Move arm to ED900, inserting arm into operator spindle at a 90⁰ angle (Fig. 16.2.5). 4. Insert M8 SHCS through drive arm and axle extension.
Page 45
ED900 Installation Instructions – Single door Chapter 16 Fig. 16.2.7 Arm assemblies attached to door and ED900 16.2.5 Connect adjustment arm to drive arm. 1. Loosen the two adjustment M6 x 10 mm flanged button head screws (Fig. 16.2.9).
ED900 Installation Instructions – Single door Chapter 17 17 Arm with track mount installation 17.1 Arm with track installation NOTICE Reference Chapter 13 for pull arm and pull arm as push installation templates. 17.2 Splined arm and track assemblies Fig.
ED900 Installation Instructions – Single door Chapter 17 17.6 Fasten track assembly to door 17.6.1 Mount track assembly on door. Fig. 17.6.1 Track assembly Track CAUTION Fixing piece Insure track hardware is Slide shoe assembled for hand of door.
ED900 Installation Instructions – Single door Chapter 17 17.7 Arm assembly Fig. 17.7.1 Arm assembly 17.8 Arm assembly with CPD lever 17.8.1 Arm with CPD lever assembly. Fig. 17.8.1 Slotted Fig. 17.8.2 M6 x 10 spring SHCS M6 x 10 SHCS...
ED900 Installation Instructions – Single door Chapter 17 17.9 Fasten arm to ED900 operator 17.9.1 Mount drive arm to operator. Fig. 17.9.1 Mount drive arm to operator at 12 degrees WARNING 12˚ Use caution when working in proximity of door and pull arm!.
Page 51
ED900 Installation Instructions – Single door Chapter 17 Fig. 17.9.7 Fastening drive arm to pivot pin 17.9.2 Attach drive arm to pivot pin. 1. Open door as required to access pivot pin M8 socket head. 2. Use 6 mm T handle hex key to rotate pivot pin M8 socket head into drive arm and tighten.
18.4.2 Use of T275 track and pull arm (Fig. 18.4.1). Value of parameter rd must be reduced by 3/16" [30]. • Example: ED900 with T275 track in pull installation with reveal of 30 mm (1 1/8"). Parameter rd setting = 0. (Reveal of 30 mm - 30 mm).
ED900 Installation Instructions – Single door Chapter 19 19 Operator spring tension 19.1 Set ED900 operator spring tension Fig. 19.1.1 Spring tension adjustment Spring tension adjustment 19.1.1 Spring tension setting revolutions. 19.1.2 Operator spring tension function. 1. Spring tension sets closing force on door.
ED900 Installation Instructions – Single door Chapter 21 21 Power fail closing speed 21.1 Set power fail closing speed Fig. 21.1.1 Power fail closing speed potentiometer Power fail closing speed potentiometer Control board 21.1.1 Power fail closing speed Fig. 21.1.2 Power on switch potentiometer.
ED900 Installation Instructions – Single door Chapter 22 22 Parameters 22.1 Parameters 22.1.1 Firmware version and updates. 22.1.4 Changing parameter values. • Operator firmware version is displayed during first 1. Set program switches to the CLOSE position commissioning. Reference Chapter 23.
Page 58
ED900 Installation Instructions – Single door Chapter 22 22.1.5 Configuration parameters TIPS AND RECOMMENDATIONS Parameter Description Driving parameter details can be found in Appendix A. Installation type Reveal depth Driving parameter Door width Description Input 4/4a and X3, 1G 24V locking...
Page 59
CPD lever in a pull installation. • Example: ED900 with arm and CPD lever in pull installation with reveal of 30 mm (1 1/8"). Parameter rd setting = 0 (Reveal of 30 mm - 30 mm).
ED900 Installation Instructions – Single door Chapter 23 23 Single door first commissioning 23.1 First commissioning TIPS AND RECOMMENDATIONS Conditions prior to commissioning. Accessory wiring. 1. ED900 operator is installed. Termination of accessory wiring to the ED900 2. Standard push arms or arm with tracks are active door operator should be done only after installed.
ED900 Installation Instructions – Single door Chapter 23 23.2 Set configuration parameters 23.2.1 Set parameter AS, installation type. Fig. 23.2.1 4 button keypad, 2 digit display Step 1 Press PRG greater than 3 s to enter Four button Press...
ED900 Installation Instructions – Single door Chapter 23 23.4 Perform learning cycle CAUTION Step 1 Secure motion range of door. Learning cycle must be performed while Set program switch to CLOSE position, Step 2 motor is cold! Fig. 20.4.1.
ED900 Installation Instructions – Single door Chapter 26 26 Set track bumper stop 26.1 Set track bumper stop position 26.1.1 Set bumper stop position. Fig. 26.1.1 Program switch OPEN position 1. Set program switch to OPEN. 2. Door moves to set opening angle.
ED900 Installation Instructions – Single door Chapter 27 27 Install push arm door stop 27.1 Install push arm door stop (optional assembly) 27.1.1 Assemble bumper stop. Fig. 27.1.1 Door stop assembly 1. Attach bumper to bumper mounting Door stop assembly plate with 1/2"...
ED900 Installation Instructions – Single door Chapter 28 28 Install ED900 cover, end caps and spindle caps 28.1 Install cover and end caps 28.1.1 Install covers. Fig. 28.1.1 ED900 standard cover 1. Align cover with operator, press inward until cover snaps into place.
Fig. 28.3.1 Spindle caps 28.3.1 Install spindle caps. 1. Install spindle caps on ED900 cover. Spindle cap Spindle cap Fig. 28.3.2 Spindle cap installation, ED900 cover top Spindle cap Spindle cap Fig. 28.3.3 Spindle cap installation, ED900 cover bottom Spindle cap 29 Install door signage 29.1 Install door signage...
ED900 Installation Instructions – Single door Chapter 30 30 ANSI/BHMA standards 30.1 A156.19 Low energy power operated doors The following table references portions of content from ANSI/BHMA A156.19. Refer to the standard, available through ANSI or BHMA for additional information. Standard material reprinted with BHMA permission.
Page 71
ED900 Installation Instructions – Single door Chapter 30 30.1.2 A156.19, Table I: Minimum opening and closing times. "W" door weight, pounds [kg] "D" door width, inches [mm] 100 [45.4] 125 [56.7] 150 [68] 175 [79.4] 200 [90.7] 30 [762] 36 [914] 3.0 s...
31 Upgrade cards 31.1 Upgrade cards 31.2 Container module 31.1.1 Upgrade card installation. 31.2.1 Container module dormakaba upgrade cards can be used to expand the range of • The first upgrade card installed becomes functions of ED900 operators. the container module.
ED900 Installation Instructions – Single door Chapter 31 31.3 Installing upgrade cards 31.3.1 Set program switch to CLOSE. 31.3.3 Installing additional upgrade cards. Upgrade card slot Next upgrade card Set program switch to Close. Container module 1. Remove container...
32.2.3 Cleaning WARNING Cleaning of ED900 cover surfaces should be done with program switches in Close position! AUTOMATIC CAUTION ED900 cover can be cleaned with a damp cloth and DOOR DD0586-010 commercial cleaning agents. ACTIVATE SWITC H TO OPERATE TIPS AND RECOMMENDATIONS Abrasive (scouring) agents should not be used as they may damage cover surface.
ED900 Installation Instructions – Single door Chapter 32 32.4 Pull arm maintenance Fig. 32.4.1 Arm and track assembly Fig. 32.4.5 Program switch 32.4.1 Track mounting screws. 1. Set program switch to CLOSE. 2. Remove track end caps 3. Check tightness of track mounting screws.
ED900 Installation Instructions – Single door Chapter 32 32.5 Arm fasteners – torque requirements 32.5.1 Check drive arm M8 SHCS torque. Fig. 32.5.1 Arm M8 SHCS cap 1. Set program switch to CLOSE. 2. Remove cap over M8 SHCS.
ED900 Installation Instructions – Single door Chapter 32 32.6 Push arm maintenance Fig. 32.6.1 Push arm assembly 32.6.1 Push arm maintenance. WARNING Set program switch to CLOSE before performing maintenance! 1. Adjustment arm. • Check for wear or damage.
ED900 Installation Instructions – Single door Chapter 32 32.7 ED900 brake maintenance 32.7.1 Adjustment of air gap: Fig. 32.7.1 ED900 operator brake to brake disc (Fig. 32.7.2). TIPS AND RECOMMENDATIONS Reference drawing: 254197-01-50 WARNING Brake assembly Set program switch to CLOSE Fig.
Page 80
ED900 Installation Instructions – Single door Chapter 32 32.7.2 Torque setting of M3 x 5 SHCS. Fig. 32.7.5 M3 x 5 SHCS • 5.3 in-lb + 0.9 in-lb [0.6 Nm +0.1 Nm] Brake assembly Brake disc assembly M3 x 5 SHCS Fig.
2 - 27* See Chapter 25. °/s *ED900: maximum closing speed 27⁰/s in low energy mode. Hold open time, automatic mode 1. Hold open time starts once all internal, external, safety and push and go inputs have been opened or dropped, and door is in an open position.
Page 82
ED900 Installation instructions – Single door Appendix A A.1.1 Driving parameters detail. Value Factory Parameter Units Description range setting Safety sensor test Safety sensor parameter ST must be set to sensors used and if they are active-high or active-low. See E 04 safety sensor test error, Appendix B.
Page 83
.45- 3.4 1.35 See Chapter 30. 4. ED900 low energy operator: static force range is reduced. Static force in closing direction 1. Static force in closing direction (basic parameter for wind load control). Static force on door closing edge can be changed using this parameter.
Page 84
ED900 Installation instructions – Single door Appendix A A.1.1 Driving parameters detail. Value Factory Parameter Units Description range setting Motor driven latching action angle Door opening angle at which motor driven latching action EP is activated. • Starting angle of the latching angle adjustable from 10°.
Page 85
1. Status relay activated when door is opened further than opening angle parameter OA, set during learning cycle. 2. Parameter OA value can only be changed using dormakaba handheld or by performing another learning cycle. Locking device output configuration;...
Page 86
Service interval is reset to 12 months. • Yellow LED not illuminated. 0 - 1 2. Parameter is then automatically reset to "0". 3. Values other than default values must be set using dormakaba USA, Inc. handheld: • Maintenance interval •...
Page 87
ED900 Installation Instructions – Single door Appendix A A.1.1 Driving parameters detail. Value Factory Parameter Units Description range setting Door closer mode 1. Automatic mode. This mode is applicable whenever door is mainly opened automatically and where motion detectors are installed.
Page 88
ED900 Installation instructions – Single door Appendix A A.1.1 Driving parameters detail. Value Factory Parameter Units Description range setting Not used. Upgrade card professional, impulse relay 1. Once upgrade card installed, parameter value will automatically change to 1. Not available 2.
Page 89
ED900 Installation Instructions – Single door Appendix A A.1.1 Driving parameters detail. Value Factory Parameter Units Description range setting Backcheck when door opened manually 1. Angle after which door is braked when manually opened. 2. Back check level is automatically optimized during manual door opening cycles. This...
ED900 Installation instructions – Single door Appendix B Appendix B – Troubleshooting Information and error codes Fig. B.1.1 User interface B.1.1 Overview 4 button keypad Operator monitors internal circuits and external safety 2 digit display circuits managed by the operator.
ED900 Installation Instructions – Single door Appendix B B.1.7 Error message memory. 1. There are ten error message memory locations; E 0 through E 9. 2. The latest error message is always stored in error memory location E 0: •...
3. If ln 08 still present, check activators or system wiring. Upgrade card error 1. Installed upgrade card cannot be removed from ED900. • Installed upgrade card has 2. If more than one upgrade card is installed, the first card installed becomes been removed.
ED900 Installation Instructions – Single door Appendix B B.3.1 Troubleshooting chart, information messages. Display Description Troubleshooting information messages Communication error, double Reference ED900 double door installation manual. door system 1. Check communication cable connection at the two operators. •...
Page 94
ED900 Installation instructions – Single door Appendix B B.4.1 Troubleshooting chart, "E" codes. Display Red LED • Description Troubleshooting error codes Overcurrent detection 1. Motor is consuming too much power, check for any external • Motor is consuming more Flashing causes.
ED900 Installation Instructions – Single door Appendix C Appendix C – dormakaba handheld dormakaba handheld terminal C.1.2 Handheld key functions. 1. OFF ON, switches Handheld on or off. Fig. C.1.1 dormakaba handheld 2. Function keys F1 - F3, trigger functions shown in bottom line of display (e.g., "RPT"...
ED900 Installation instructions – Single door Appendix C NOTICE Parameters and detail may change depending on firmware version. dormakaba handheld; configuration parameters "#" refers to reference numbers in Parameter list, Chapter 22. C.2.1 Configuration parameters. Parameter and Parameter and...
ED900 Installation Instructions – Single door Appendix C C.2.1 Configuration parameters. Parameter and Parameter and Description / Selections Description / Selections default default Manual mode on. NO contact; night- Manual bank function mode Normal* Manual mode disabled. triggered while contact closed.
ED900 Installation instructions – Single door Appendix C dormakaba handheld; special functions (Upgrade cards) ED900 C.4.1 Special functions (upgrade cards). Parameter and Parameter and Description / Selection Description / Selection default default • locked: not available locked Upgrade •...
ED900 Installation Instructions – Single door Appendix C dormakaba handheld; diagnostics C.5.1 Diagnostics Parameter name Description Setting Parameter name Description Setting FW vers BM Displays firmware (FW) x.x y y (e.g.,0190 Wartungs x x y y (month, version of basic module v 1.9.0)
Page 100
ED900 Installation instructions – Single door Appendix C C.5.1 Diagnostics Parameter name Description Setting Parameter name Description Setting Clamp X3, 1G and 3, 0, low active Klemme 1G 24 V out Setting code (function on) 1, function off Opening width Displays opening angle ( ..
ED900 Installation Instructions – Single door Appendix C New dormakaba handheld; language change to English C.6.1 New dormakaba handheld; language 5. Press to select Sprachen (Fig. 26.6.6). ENTER Fig. C.6.1 change. Fig. C.6.7 Sprachauswahl (Language dormakaba handheld If German language is displayed on screen...
ED900 Installation instructions – Single door Appendix C dormakaba handheld; firmware update C.7.1 Firmware update procedure CAUTION For all firmware changes, set program switch to CLOSE and allow door to close completely before any updates are made! Fig. C.7.1...
Page 103
ED900 Installation Instructions – Single door Appendix C Fig. C.7.5 Select Firmware upload Fig. C.7.4 Select UpDoLd ENTER button F2 button Up/down arrows Connected with: DOWN/UPLOAD ED900_US Download data FW-Version: 01.30 Upload file Revision: Firmware upload Door Again UpDoLd Door 4.
Need help?
Do you have a question about the ED900 and is the answer not in the manual?