thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
instruction
manual
1. safety
1.1.
Personal Precautions
When using the analyser, please observe all normal safety rules concerning:
9
Protection against the dangers of electric current.
Protection of the analyser against misuse.
Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, these must be replaced
9
with genuine Sealey leads with the same electronic ratings. Failure to do so will invalidate the warranty.
8 8 do not use leads if damaged or if the wire is bared in any way.
8 8
1.2.
general safety
Familiarise yourself with the application and limitations of the analyser as well as the potential hazards. IF IN ANY DOUBT CONSULT A
9
QUALIFIED ELECTRICIAN.
When the analyser is linked to a measurement circuit, do not touch unused analyser terminals.
9
When the scale of the value to be measured is unknown set the selector to the highest range available.
9
Before rotating the function dial to change functions, disconnect test leads from the circuit under test.
9
Warning! Never perform resistance measurements on live circuits. only measure on disconnected circuits.
Use caution when working with voltages above 60V dC or 30V AC. Keep fingers behind the probe barriers whilst measuring.
9
8 8 When not in use, store the analyser carefully in a safe, dry, childproof location. Storage temperature range -10°C to 50°C.
9
8
8 8 never apply voltage or current to the analyser that exceeds the specified maximum.
8 8
The user shall ensure that test probes are correctly selected in order to prevent danger. Probes shall be selected to ensure that
9
adequate barriers guard against inadvertent hand contact with live conductors under test and that probes have minimal exposed probe
tips. Where there is a risk of the probe tip short circuiting with other live conductors under test, it is recommended that the exposed tip
length shall not exceed 4mm.
8 8 Warning! do not make current measurements on the 10A scale for longer than 15 seconds in every 15 minutes.
8
exceeding 15 seconds may cause damage to the analyser and test leads.
2. introduction
large, hi-contrast lCd display with 34mm high digital read-out. durable bi-composite case and integral stand, suitable for the toughest
workshop conditions. Test lead Connection feature indicates correct hook-up. Includes over-ranging, auto-zeroing, data hold, auto power-off
and low battery display functions. Supplied with capped test probes and K-type thermocouple.
fig.1
© Jack Sealey limited
11 function digital automotive analyser
ta102
model no:
Warning!
electricity
Original Language Version
TA102 | Issue:5 (H,F) 01/06/18

Advertisement

loading

Summary of Contents for Sealey TA102

  • Page 1 IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 88 Warning! Risk of electrocution. High voltage circuits, both AC and dC are very dangerous and should be measured with great care. ‰ 5.1. operating temperature range 0°C to 40°C. 5.2. Remember to turn off the analyser when measurement is completed. Original Language Version TA102 | Issue:5 (H,F) 01/06/18 © Jack Sealey limited...
  • Page 3 Connect the black test lead to an earthing point, or the negative terminal of the vehicle battery. note: Refer to the vehicle manufacturer’s manual for the specific location and more details. TA102 | Issue:5 (H,F) 01/06/18 Original Language Version...
  • Page 4 Turn the analyser off when not in use and remove the battery if stored for a long period of time. do not store the analyser in a place of high humidity or high temperature. Parts support is available for this product. Please email sales@sealey.co.uk or telephone 01284 757500 Weee regulations dispose of this product at the end of its working life in compliance with the eU directive on Waste electrical and electronic equipment (Weee).