These can result from taps being turned on or off or toilets being flushed. Mira Go 8.5 - A 8.5 kW 240 V AC heater with a Mira React adjustable spray handset with three different spray actions (Start, Soothe and Force). Supplied complete with flexible hose, adjustable clamp bracket assembly, soap dish, slide bar and supports and hose retaining ring.
1.7. DO NOT fit any form of outlet flow control as the outlet acts as a vent for the heater tank body. Only Mira recommended outlet fittings should be used. 1.8. There are no user serviceable components beneath the cover of the Mira Go. Only a competent tradesperson should remove the cover.
Page 5
1.10. Turn off the electrical and water supplies before removing the cover. The electricity must be turned off at the mains and the appropriate circuit fuse removed, if applicable. Caution! Mains connections are exposed when the cover is removed. 1.11. Refer to the wiring diagram before making any electrical connections (refer to Section 5).
Page 6
2.7. Anyone who may have difficulty understanding or operating the controls of any shower should be attended whilst showering. Particular consideration should be given to the young, the elderly, the infirm, or anyone inexperienced in the correct operation of the controls. 2.8.
ü Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included. 1. Mira Go 8.5 1 x Mira Go 8.5 3 x Wall Plug 3 x Fixing Screws 2. Documentation 1 x Installation, Operation and Maintenance Guide...
Solenoid Valve 86 Brown 88 Red On/Off Load 94 Blue 90 Blue 91 Green Tank Connection 92 Green Inlet Connector Internal Wiring Diagram Mira Go Clamp Bracket Double-pole Temperature Isolating Switch Start Stop Hose Retaining Ring Isolating Valve Mains-fed Cold...
Mira produce a pumped electric shower (Elite 2) designed for this particular application. 1.3. The Mira Go is suitable for installation within the shower area. It is fitted with a pressure relief device and must be positioned over a water catchment area...
Page 11
15 mm compression fitting (not supplied) from the top, bottom or back. 1.5. Do not fit the Mira Go to the wall and tile up to the case. The Mira Go must be fitted on to a finished flat and even wall surface (this wall surface should be tiled or waterproofed).
Page 12
As this Mira Go is a high power unit, it is essential to contact your electricity supply company to ensure that the supply is adequate for the Mira Go. Voltage drop due to local heavy demand will reduce the shower's performance.
Page 13
40A MCB type B and allowing for a 5 Volt drop: Mira Go 8.5 kW (240 V AC) at 240 V - 19 Metres 2.5. A 30 mA residual current device (RCD) should be fitted. This may be part of the consumer unit or a separate unit.
1. Mira Go Warning! Turn off the electrical and water supplies before proceeding with the installation of the Mira Go. The electricity must be turned off at the mains and the appropriate circuit fuse removed, if applicable. Note! An installation template is supplied to help you install the Mira Go.
Page 15
1.10. Drill and plug the top two fixing holes. Secure the Mira Go to the wall with the screws provided. Drill the bottom fixing hole with the product in place. Alternative fixings (not supplied) may be necessary for some wall structures.
Page 16
1.12. Make the connection to the mains-fed cold water supply pipe. 1.13. Bring the electrical supply cable into the case through one of the cable entry points. 1.14. Strip back sufficient of the outer cable insulation to enable routing to terminal block.
Section Commissioning 1. Pre-testing Your Mira Go If you are unsure how electric showers work, please read through, Section 11, Operation before continuing. 1.1. Make sure that the electrical supply is turned off at the Start Stop mains. Temperature 1.2. Turn the BOTTOM control knob fully anticlockwise to the full cold position.
Page 18
Isolate the power at the double pole switch. Note! A slight hissing sound may be heard from the Mira Go during operation. High mains water pressure and high shower temperatures will effect the tone. This is quite normal in use.
Section Maintenance 1. General Read the section “Important Safety Information” first. Providing the shower has been correctly installed and is operated in accordance with the instructions contained in this guide, difficulties should not arise. If any maintenance is required then it must be carried out by a competent tradesperson for whom the maintenance instructions are provided.
Page 20
3.8. Remove the heater tank and the inlet connector assembly from the flow valve and switch assembly. 3.9. Remove the microswitches from the flow valve and switch assembly. 3.10. Make a note of the positions of the solenoid wires on top of the heater tank. Remove the solenoid wires.
Page 21
4. Heater Tank - Removal and Installation Warning! Make sure that the electrical supply is turned off at the mains and the appropriate circuit fuse is removed. Turn off inlet water supply. 4.1. Remove the three cover retaining screws, the cover and the service tunnel. 4.2.
Page 22
4.15. Refit the components in reverse order. Make sure that the electrical wires are installed in the correct positions. Thermal Switch Heater Tank Heater Tank Retaining Screws Switch Assembly Flow Valve 15mm Outlet Connector compression straight connector (not supplied) Clamp Bracket Solenoid Valve Inlet Connector Clamp...
Page 23
5.4. Remove the screws that hold the inlet clamp bracket in position and remove the clamp bracket. 5.5. Remove the screws that hold the flow valve, switch assembly and heater tank in position. 5.6. Carefully pull the flow valve, switch assembly and heater tank away from the case.
1.3. The Mira Go is designed to stabilise temperature changes caused by water pressure fluctuations. These can result from taps being turned on or off or toilets being flushed.
Page 25
The left-hand scale is temperature rise. (Temperature rise = Showering temperature minus the incoming cold water temperature.) Example: For the Mira Go 8.5 kW on full power setting with an incoming water supply at 10°C and a showering temperature at 42°C, the temperature rise is 32°C. The flow rate is therefore, 4 l/min.
Page 26
Lack of regular spray plate cleaning will lead to poor performance and cause early failure of the Mira Go. Refer to the Installation, Operation and Maintenance guide for the fittings.
Page 27
High Medium COLD Temperature Start Stop Press to Start / Stop Hotter Cooler Shower Controls...
Section Fault Diagnosis Customer Fault Diagnosis Warning! There are no user serviceable components beneath the cover of the appliance. Only a competent tradesperson should remove the cover. The trouble shooting information tabled below gives details on what you can do as a user without removing the cover, should you encounter difficulties whilst operating the shower.
Page 29
Malfunction Cause Remedy (Continued) Remove and clean (Refer to Handset sprayplate Maintenance in the I, O & blocked. M guide for the fittings). Other outlets being used Ensure other outlets e.g. whilst showering, causing bath, washing machine or water pressure to drop dishwasher are not in use below minimum required whilst showering.
Page 30
Installer Fault Diagnosis: refer to appliance diagram and customer fault diagnosis Read the section “Important Safety Information” first. Providing the shower has been correctly installed and is operated in accordance with the instructions contained in this guide, difficulties should not arise. If any maintenance is required then it must be carried out by a competent tradesperson for whom the fault diagnosis chart and maintenance instructions are provided.
Page 31
Malfunction Remedy Cause Appliance fails to Electrical supply isolated Switch on. produce hot water at double pole switch (the in any switch pull-cord). position. Fuse 'blown' or MCB/RCD Correct the fault and tripped - indicating an renew the fuse or reset electrical fault e.g.
Page 32
Malfunction Cause Remedy Operation of Flow valve faulty. Renew the flow valve. temperature knob has little or no Handset spray plate Remove and clean, refer effect on water to Maintenance in the blocked. temperature. shower fittings I,O & M guide. No change in Contact local water Insufficient water supply...