Ireland: 2006/0462 If you experience any difficulty with the installation or operation of your new Electric Shower, please refer to ‘Fault Diagnosis’, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found in the back of this guide.
The Mira Azora comes complete with a set of Mira Energise Shower Fittings. Mira Azora 9.8 kW A 9.8 kW 240 V AC (9.0 kW 230 V AC) heater with Mira Energise adjustable spray handset with four different spray actions (start, soothe, force and eco*). Supplied complete with flexible hose, clamp bracket assembly, slide bar, supports, hose retaining ring and soap dish.
DO NOT fit any form of outlet control (e.g. Trigger handset) as the outlet acts as a vent for the tank body. Only Mira recommended outlet fittings should be used. 10. Make sure all electrical connections are tight, to prevent overheating.
Page 5
16. If pipework and/or electical cables enter the shower from the rear through a hole in the wall . Provision must be made to prevent water ingress back into the wall structure. 17. If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure there are no leaks 18.
PACK CONTENTS CHECKLIST Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. Mira Azora 1 x Mira Azora 1 x Olive 1 x Compression Nut 3 x Fixing Screws 3 x Wall Plugs...
• The terminal block will accept cable up to 16 mm • The Mira Azora is suitable for installation in Zone 1 and is rated IPX4. 3. Standards and Approvals • The Mira Azora complies with all relevant directives for CE marking.
Page 8
However, there will be occasions when it will not provide a suitable solution. In these instances an outlet double checkvalve, e.g. a Mira DCV-H, MUST be fitted. This will increase the required supply pressure typically by 10 kPa (0.1 bar).
• In a domestic installation, the rating of the electricity supplier’s fuse and the consumer unit must be adequate for the additional demand. All Mira electric showers are high power units, it is essential to contact your electricity supplier to ensure that the supply is adequate for the product.
Installation of Mira Azora Warning! Turn off the electrical and water supplies before proceeding with the installation of the Mira Azora. The electricity must be turned off at the mains and the appropriate circuit fuse removed, if applicable. Note! An installation template is supplied to help you install the Mira Azora.
Page 11
(2 gallons) of water into a bucket or catchment area. Turn off the water supply. An installation template is supplied to help you install the Mira Azora. Put the installation template on the wall and mark through the positions of the fixing holes.
Page 12
Feed cable into Case. Fit Earth sleeve (not supplied) and then strip insulation. Do not twist cable cores. Important! Make sure that the inlet earth wire is routed as shown. Failure to do so may cause product malfunction. L = BROWN E = GREEN/YELLOW Firmly connect the conductors.
Page 13
Holes For Cover Retaining Screws Fixing Screw Terminal Block Heater Tank Electrical Supply Cable Inlet Connector Assembly Cold Water Supply Pipe (Bottom Entry)
COMMISSIONING Before carrying out the commissioning procedure install the Shower Fittings, refer to the Shower Fittings Installation and User Guide. If you are unsure how an electric shower works, please read through the section “User Instructions” before continuing. Electrical supply is turned Turn control to full cold.
Page 15
0 - 10 Secs Turn control to full cold. Set control to ‘II’. The temperature will rise slightly. 5 - 10 Secs The temperature will rise further. Set control to ‘III’. Press STOP. Adjust temperature as required. Flow rate will adjust automatically. 0 - 5 Secs Isolate power.
USER INSTRUCTIONS How Your Electric Shower Works Heated water is produced by adjusting the flow of cold water passed through a heater tank. The shower has three heater settings. The warmer the shower, the lower the flow rate and vice versa.
Page 17
Thermostatic (Temperature-Stable) The shower's top priority is to keep the desired water temperature constant. Electric showers with thermostatic control are able to keep a stable temperature across the range from hot to cold, whilst also dealing with fluctuations in electrical and water supplies.
Page 18
Using your Shower Read the section “Important Safety Information” first. Switch on electrical supply. Press the ‘Start/Stop’ button. Set to desired position. Check water temperature before entering shower. Allow 10 - 15 seconds for any temperature adjustments to reach the handset. P r e s s S TO P b u t t o n .
Page 19
The Effect of Seasonal Changes * * * For a cold shower select I. For a summer warm shower select II. For a winter warm shower select III. During extremes of mains water supply temperature, adjust heater setting to obtain a better showering temperature.
FAULT DIAGNOSIS The trouble shooting information tabled below gives details on probable causes and remedies should difficulties be encountered whilst the shower is in operation. Warning! There are no user serviceable components beneath the cover of the appliance. Only a competent tradesperson should remove the front cover! Symptom Start/ Heater...
Page 21
Symptom Start/ Heater Probable Cause Possible Remedy Stop Setting Light I/II/III L o w o r n o Water supply pipework or inlet Flush supply pipe. Clean inlet flow. filter restricted by a blockage or filter. partial blockage. Insufficien t water su pply Contact local water company.
Symptom Start/ Heater Probable Cause Possible Remedy Stop Setting Light I/II/III Water will not Inlet valve, solenoid, or start/ Replace as necessary. turn off. stop switch faulty. Supply pressure below 0.2 Contact local water company. bar. Check mains water static pressure.
Page 23
Inlet Filter - Cleaning/Renewing Cover Retaining Screw Read the section “Important Safety Information” first Make sure that the electrical supply is turned off at the mains and that the water supply is fully turned off. Remove the three screws and the cover.
Cover Assembly - Stones 1634.124 Cover Assembly - Dots ACCESSORIES Genuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guide) or from approved stockists or merchants. Showerhead Holder Shower Seat Double Outlet Check Valve (DCV-H) White - 2.1536.128...
WIRING DIAGRAM Thermal Cutout Disc BROWN BROWN BROWN Pressure/Power BROWN Selector Switch Start/Stop Solenoid L.E.D. Valve BROWN BLACK BLACK Load START/STOP BLUE BROWN BLACK BLUE GREEN Tank Connection Inlet Connector GREEN Internal Wiring Diagram...
fi lters) or where no fault has been found with guarantee period and beyond. You have the assurance of a the product. fully trained Mira Technician, genuine Mira spare parts and Water or electrical supply, waste and isolation issues. a 12 month guarantee on any chargeable work done.
Need help?
Do you have a question about the Azora and is the answer not in the manual?
Questions and answers