Structural or electronic modifications or changes made to the device. software INTENDED USE All Vallox ventilation units have been designed to provide appropriate and continuous ventilation so as to present no threat to health and to maintain structures in good condition. IMPORTANT...
Vallox 245 MV VKL has a liquid circulation post-heating radiator and country. two electric 1500W additional heating resistors. MOUNTING OPTIONS • Vallox 245 MV must always be installed on the floor by using a floor rack. SYSTEM DESCRIPTION Internet 2. WLAN MyVallox Cloud 3.
Ventilation unit control options. please go to www. please go to www. techmanuals.info/ techmanuals.info/ ValloxMV/ENG/ ValloxMV/ENG/ Operation of the Vallox ventilation unit can be controlled by the onlinehelp/webhelp onlinehelp/webhelp following means: • Through the My Vallox Control panel installed in the building. •...
MAIN PARTS Vallox 245 MV / Vallox 245 MV VKL R model in the figure Supply air fan Extract air fan Internal humidity sensor (behind the electric box) Fine filter for supply air Internal carbon dioxide sensor (behind the electric box)
MOUNTING ON THE FLOOR Vallox 245 MV is always mounted on the floor. Adjust the adjusting legs so that the unit is level. NOTE When installing the unit, reserve a space of at least 800 mm in front of the unit for servicing purposes.
DIMENSIONS AND DUCT OUTLETS Main parts Dimensions and duct outlets Dimensions 1038 R model in the figure. In the L model, the parts are mirrored. 6. Coarse filter for supply air 1. Extract air fan 7. Coarse filter for extract air 2.
NOTE Using original Vallox filters ensures that the ventilation unit remains in top condition, giving the best results. To select and order filter packages, please go to: filters.vallox.com To replace the filters: Disconnect the ventilation unit from the mains electricity supply.
CLEANING THE HEAT RECOVERY IMPORTANT CELL Handle the cells carefully! For example, do not lift the cells by Check that the heat recovery cells are clean roughly once a the layers. The cell year when the filters are being changed. Clean by washing as layers are very thin and required.
REMOVING THE RESISTOR 10 x To remove the resistor: Disconnect the ventilation unit from the mains electricity supply. 2. Open the doors of the unit. 3. Open the resistor box by undoing the mounting screws (10 PZ2 screws). 4. Remove the quick connector of the resistor: a.
VALLOX 245 MV VKL TECHNICAL SPECIFICATIONS Product title Product number Vallox 245 MV VKL R 3513150 Vallox 245 MV VKL L 3513250 Air volumes Fans Supply air 219 dm /s, 100 Pa Supply air 0,170 kW 1,25 A EC Extract air...
Page 15
A Thermal input, kW B Difference in water temperature, °C C Water flow dm³/s D Air flow dm³/s Vallox 245 MV liquid radiator t =15°C, t =55°C Vallox 245 MV liquid radiator t =15 °C, t =70°C...
DUCT RADIATOR OPERATION Always follow first and foremost the connection diagram provided by the HVAC designer or heat pump manufacturer. If the duct NOTE: Also read the duct radiator manual. radiator is used in the supply air duct, it The accompanying figure shows an example of the can only be used for arrangement for connecting the heating/cooling radiator unit cooling.
Feed from the distribution board External electrical junction box for the MV Air extraction External NTC sensor for Vallox MV ventilation units Duct radiator (reverse connection) 24 VDC relay/contactor for controlling the pump and the solenoid valve. Not included in the delivery.
EXPLODED VIEW AND PARTS LIST NO. PART NO. PART CODE NO. PART CODE CODE Lower door 3539400 Siphon Vallox Silent Klick 3494701 MyVallox Control panel 949033 Finger screw for the door 990713 Base assembly 3527500 MyVallox humidity sensor 946149 MyVallox carbon dioxide...