Page 4
OUTDOOR AIR FILTER F7 CARBON DIOXIDE SENSOR HEAT RECOVERY CELLS (2) HUMIDITY SENSOR INTERNAL HUMIDITY SENSOR SUMMER/WINTER DAMPER (BEHIND THE ELECTRIC BOX) OUTDOOR AIR FILTER G4 POST-HEATING LIQUID RADIATOR EXTRACT AIR FILTER G4 POST-HEATING RADIATOR 127( For more detailed instructions, go to www.vallox.com...
Page 6
Furthermore, all local accident prevention regulations must be observed. ,17(1'(' 86( All Vallox ventilation units have been designed to provide appropriate and continuous ventilation so as to present no threat to health and to maintain structures in good condition.
Page 8
It also reduces the risk of knowledge and experience do not moisture damage. ensure safe operation of the unit. Operation of the Vallox ventilation unit can be controlled by the Such persons can use the unit following means: under supervision, or by following •...
Page 10
%$6,& 6(77,1*6 6(7 7+( 25 +285 &/2&. The 24-hour clock is used by default. To use the 12-hour clock: 1. Select 0LQXV. The +RXU 7LPH setting value is changed to 2II. 2. Proceed to the next phase by pressing the 5LJKW DUURZ button.
Page 12
(;3(57 6(77,1*6 )$1 6(77,1*6 To set the output ratio between the supply and extract air fans: :$51,1* The supply and extract air settings ,03257$17 have been completed by a Adjust the air flows according to the values specified in the specialist during setup of the ventilation plan.
Page 14
(;3(57 6(77,1*6 1. Use the 3OXV and 0LQXV buttons to turn the profile timer function on or off. The options are: 2Q — When the timer is on, the %RRVW profile is used only for the period specified in the timer. 2II —...
Page 16
9(17,/$7,21 352),/(6 &+$1*,1* 7+( 352),/( 1. Press WKH &KDQJH SURILOH button until the desired ventilation profile icon appears on the display. 2. Wait until the main display of the ventilation profile appears. 3. The ventilation profile has been changed. %52:6,1* 7+( ,1)250$7,21 2) 7+( $7 +20( $:$< $1' %2267 352),/(6 To view the profile settings: 1.
Page 18
7(03(5$785(6 $1' 6(16256 9,(:,1* 7(03(5$785( '$7$ 1. Select 6HWWLQJV > 7HPSHUDWXUHV DQG VHQVRUV 2. Select 2.. The summary display of temperatures and sensors shows the following information: ,QGRRU — Indicates the temperature of the air flowing into the unit to be removed from the premises. 2XWGRRU —...
Page 20
6(77,1*6 ),/7(5 6(77,1*6 1. Select 6HWWLQJV ! )LOWHU 2. Select 2.. 3. The summary display of the filter status shows the following information: )LOWHU FKDQJHG — Indicates the date when the filter was last replaced. 1H[W UHPLQGHU — Indicates the date when a reminder to replace the filter will next be shown.
Page 22
6(77,1*6 7,0( $1' '$7( 6(77,1* 7+( 7,0( $1' '$7( The available time settings are: • Time • 24- or 12-hour clock • Automatic daylight-saving time • Date 127( The unit time will withstand a power cut of a few hours. 6(77,1* 7+( 7,0( 1.
Page 26
The filter change interval depends on the ambient dust concentration. It is recommended that the filters be changed every spring and autumn, or at the very least once a year. Using original Vallox filters ensures that the ventilation unit remains in top condition, giving the best results.
Page 28
0$,17(1$1&( )$16 Check the cleanliness of the fans when servicing the filters and the heat recovery cell. Clean the fans as required. You can clean the fan blades with compressed air or by brushing them gently. 127( Only the supply air fan is equipped with a sound-damping grid.
Page 30
0$,17(1$1&( 7528%/(6+227,1* 127( Error messages are displayed on the control panel and in the MyVallox Home and MyVallox Cloud services. )$8/7 &$86( 0($685(6 Message on the user interface: The extract air fan has stopped. Make sure that the fan is not running. The fan cabling Extract fan stopped and operation must be checked, and if necessary the fan must be replaced.
+($7,1* $1' &22/,1* 5$',$725 23(5$7,21 &+$576 RADIATOR (REVERSE CONNECTION) SUPPLY AIR OUTDOOR MV ventilation unit INPUT FROM THE DISTRIBUTION BOARD HEAT PUMP HEAT COLLECTION CIRCUIT 23(5$7,21 $1' 6$03/( &211(&7,21 127( +($7,1* IROORZ ILUVW DQG IRUHPRVW WKH FRQQHFWLRQ GLDJUDP /:$<6 SURYLGHG E\ WKH +9$& GHVLJQHU RU KHDW SXPS PDQXIDFWXUHU The pump starts when the outdoor The accompanying figure shows an example of the arrangement air temperature drops below the...