Detailed Specifications - Infinity Beta SW Series Service Manual

Hide thumbs Also See for Beta SW Series:
Table of Contents

Advertisement

CSW-10
CSW-10
450W Powered Sub/ Plate Amp
LINE VOLTAGE
Yes/No
US 120VAC/60Hz
EU 230VAC/50-60Hz
Parameter
Specification
Amp Section
Type (Class AB, D, other)
Load Impedance (speaker)
Rated Output Power
THD @ Rated Power
THD @ 1 Watt
Dynamic Power
DC Offset
Damping factor
Input Sensitivity
Input Frequency
Left or Right inputs
Left & Right with LFE or LP
filter OFF Mode selected
Speaker/Hi Level Input
Signal to Noise
SNR-A-Weighted
SNR-unweighted
SNR rel. 1W-unweighted
Residual Noise Floor
Residual Noise Floor
Input Impedance
Line Input (L, R,LFE)
Speaker/Hi Level Input
Filters
LP 4th order variable
Subsonic filter (HPF) 3rd Orde
Low pass filter OFF
BOS
Frequency Control
Range
Level Control
Range
Width(Q) Control
Range
4.5% to 49.5% octave
Limiter
THD at Max. Output Power
Features
Auto - On -Off
Phase switch
Volume pot Taper (lin/log)
Variable crossover 50-150 Hz
HP Speaker out
LP On- Off Select switch
Input Configuration
Line In (L,R) & LFE
Spkr/Hi Level In
Hi/Lo Line
Nom.
Yes
108-132
120
Yes
207-264
230
QA Test
Unit
Limits
n/a
D
n/a
4
Ohms
n/a
450
Watts
425
0.5
%
1
0.1
%
0.2
430
450
Watts
80
mV-DC
100
>20
DF
15
30
50
Hz
10.29
mVrms
±2dB
10.17
mVrms
±2dB
±2dB
158
mVrms
100
dBA
95
95
dBr
90
70
dBr
65
0.5
mVrms
1
0.5 mVrms(max)
1
10K
ohms
n/a
10K
ohms
n/a
50-150 Hz
± 10
Fixed Hz
± 10
Fixed Hz
± 10
--
20-80 Hz
functional 21 detent pot (0.1 oct. steps)
--
--
-14.1 to 0 dB
functional 21 detent pot (0.5dB steps)
--
--
functional 21 detent pot (5steps/0.1 octave)
YES
n/a
functional
--
YES
--
functional
0-180
deg
functional
LOG
--
functional
YES
functional
YES
functional
functional
YES
--
YES
--
functional
YES
--
functional
Unit
Vrms
Vrms
Conditions
Nominal
1 input driven
22K filter
22K filter
Power is the average measurement
of the first four consecutive peaks of
the burst signal
@ Speaker Outputs
Measured at amplifier board
Nominal Freq.
To 1 Watt
To 1 Watt
To 1 Watt
Relative to rated power (400 Watts) A-Weighting filter
Relative to rated power (400 Watts) 22K filter
Relative to 1W Output
Volume @max, using RMS reading
DMM/VOM (or A/P)
Volume @max, w/ A/P Swept
Bandpass Measurement (Line
freq.+ harmonics)
Nominal
Nominal
L or R input driven, LP Filter OFF
2
Notes
Normal Operation
Normal operation, MOMS required
Notes
Bridge type amplifier, None of the speaker
terminals must be connected to system GND at
any time.
3/20 Cycles @ 50 Hz, burst test into 4 Ohms,
input driven 6dB above its maximum sensitivity,
volume level at Maximum, RABOS Section OFF
Measured at the speaker cable. 200 Watts,
measured at speaker output terminals located at
the amp board.
Single input driven, Ap Zo=600 Ohms, LP ON,
RABOS OFF, Volume ctrl & crossover at max
Single input driven , Ap Zo=600 Ohms, LP OFF,
RABOS OFF, Volume ctrl & crossover at max
Single input driven, Ap Zo=25 Ohms, Normal,
RABOS OFF, Volume ctrl & crossover at max
22K filter
Refer to AP graph 1
Refer to AP graph 1
Refer to AP graph 1
Refer to AP graph 2
Refer to AP graph 3
Refer to AP graph 4
No switch to select the ATO mode is provided,
Refer to ATO section
A Taper
4th Order LP Filter, 2nd order fix and 2nd order
variable.
Pass through from the speaker input section
Disables LP filter, intended for LFE
Dual RCA jack, L or R is used in LFE mode
Binding post connector L&R