Download Print this page
ABB SACE Tmax T7D/PV Installation Instructions Manual

ABB SACE Tmax T7D/PV Installation Instructions Manual

Advertisement

Quick Links

Doc. N.° 1SDH000789R0005 - B1319
SACE Tmax T7D/PV - T7D/PV-E
Istruzioni di installazione Tmax T7D/PV - T7D/PV-E
Installation instructions
Tmax T7D/PV - T7D/PV-E
Installationsanleitung Tmax T7D/PV - T7D/PV-E
Instructions pour l'installation Tmax T7D/PV - T7D/PV-E
Instrucciones de instalación Tmax T7D/PV - T7D/PV-E
T7D/PV
(UP TO 1100V)
T7D/PV-E
(UP TO 1500V)
B
A
1,2 Nm
2,5 Nm

Advertisement

loading

Summary of Contents for ABB SACE Tmax T7D/PV

  • Page 1 Doc. N.° 1SDH000789R0005 - B1319 SACE Tmax T7D/PV - T7D/PV-E Istruzioni di installazione Tmax T7D/PV - T7D/PV-E Installation instructions Tmax T7D/PV - T7D/PV-E Installationsanleitung Tmax T7D/PV - T7D/PV-E Instructions pour l'installation Tmax T7D/PV - T7D/PV-E Instrucciones de instalación Tmax T7D/PV - T7D/PV-E...
  • Page 2 T7D/PV - T7D/PV-E Example for 1600A CABLE SECTION: 4x240mm See fig. G WITH FLANGE CON MOSTRINA Ø WITHOUT FLANGE SENZAMOSTRINA Tmax T7D/PV | ABB...
  • Page 3 Apertura mediante SOR/UVR. ATTENZIONE: Apertura mediante leva solo in caso di emergenza TERMINAL 2 Ausschaltung durch SOR/UVR. ACHTUNG: Ausschaltung durch hebel nur im Fall einer Notfall Ouverture par SOR/UVR.ATTENTION: Ouverture par levier seulement en cas d'urgence Disparo mediante SOR/UVR.ATENCIÓN: Disparo mediante palanca sólo en caso de emergencia Tmax T7D/PV | ABB...
  • Page 4 UP TO UP TO 1500V 1500V 1500V 1500V 18 Nm 224.5 CON MOSTRINA SENZA MOSTRINA WITH FLANGE WITHOUT FLANGE FCCuAl (4 x 240 mm ) 66.3 43 Nm 34.8 18 Nm 43 Nm 34.8 66.3 224.5 Tmax T7D/PV | ABB...
  • Page 5 1500 V 1500 V LOAD 1250 A 1600 A UPPER SUPPLY LOAD 1100 V 1100 V 1500 V 1500 V 1250 A 1600 A LOWER SUPPLY FCCuAl FCCuAl 1100 V 1100 V 1500 V 1500 V LOAD Tmax T7D/PV | ABB...
  • Page 6 Configurations with jumpers Example with Example with jumper for 1250A jumper for 1600A (4PS Lower Supply) (4PS Lower Supply) 18 Nm 18 Nm Tmax T7D/PV | ABB...
  • Page 7 FC Cu Al (4 x 240 mm ) 18 Nm CON MOSTRINA SENZA MOSTRINA WITH FLANGE WITHOUT FLANGE 43 Nm * UPPER SUPPLY - According to scheme L, terminals configurations must be symmetrical respect to x-x CB axis Tmax T7D/PV | ABB...
  • Page 8 (4 x 240 mm ) 18 Nm 43 Nm CON MOSTRINA SENZA MOSTRINA WITH FLANGE WITHOUT FLANGE * UPPER SUPPLY - According to scheme L, terminals configurations must be symmetrical respect to x-x CB axis www.abb.com © Copyright 2011-2017 ABB. All rights reserved.

This manual is also suitable for:

Sace tmax t7d/pv-e