JRC JCY-1900 Instruction Manual page 131

Voyage data recorder
Hide thumbs Also See for JCY-1900:
Table of Contents

Advertisement

Error
Error
code
type
000
WARNING
001
WARNING
002
CAUTION
003
CAUTION
004
WARNING
005
006
WARNING
007
CAUTION
008
WARNING
Alert indication
VDR operation failure
Recording stop
Blackout
Battery low voltage
Fan* failure in RCU
*: 1, 2
Battery failure
Battery high
temperature
Battery high charging
voltage
Chapter 6 Maintenance and Inspection
Alert contents
The RCU can't
communicate the OPU.
The data recording is
stopping.
The AC input power is
not supplied to the
RCU.
The voltage of RCU's
built-in battery is lower
than the rated value.
The RCU's built-in fan
is stopping.
The RCU's built-in
battery is deteriorating.
The temperature of
RCU's built-in battery is
higher than the rated
value.
The charge voltage of
RCU's built-in battery is
higher than the rated
value.
Actions to take
1) Check the cable.
2) Reboot the RCU.
When the data recording stopped to
prevent overwriting data, this
Follow the
message is displayed.
directions of the relevant
authorities as to whether to
restart the data recording.
About restarting the data
recording, see "4.8.4 Stopping
the recording or restarting the
recording".
1) Check the switchboard.
2) Check the POWER switch. Turn
on the POWER switch.
3) Check the AC line fuse in the
RCU. If the AC line fuse blown,
replace the fuse.
Check the RCU's built-in battery.
Turn on the POWER switch and
charge the battery.
It is necessary to replace the fan.
Please contact our head office, or a
nearby branch or local office to
request servicing.
It is necessary to replace the battery.
Please contact our head office, or a
nearby branch or local office to
request servicing.
1) Check the temperature of place
where the RCU installed.
2) Reboot the RCU and check it
works normally. If there is still a
problem, please contact our head
office, or a nearby branch or local
office to request servicing.
Reboot the RCU and check it works
normally. If there is still a problem,
please contact our head office, or a
nearby branch or local office to
request servicing.
95

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JCY-1900 and is the answer not in the manual?

Questions and answers

Arnold Delumen Aguilar
January 20, 2025

How to rebot RCU error code 106

User image 678ebabd5544d
2 comments:
Arnold Delumen Aguilar
January 20, 2025

We carried out power failure test after the test the code 106 showed and can't reset to normal

Mr. Anderson
February 4, 2025

To reboot the JRC JCY-1900 RCU with error code 106, follow this step:

1. Reboot the RCU.
After rebooting, check whether the issue is resolved.

This answer is automatically generated