【Installation Method】
A. Ceiling fixed frame method
Installation reference picture:
A
D
Install the Fixed Frame to the ceiling
Make the fixed frame.
Please use materials that can bear 8.5kg to fix the surrounding part.
The fixed frame should use sticks of 30*25mm.
Size of the inner part of the frame: 380*272mm.
If there is no exhaust pipe connects to the outdoors, please firstly install hard
exhaust pipe of inner diameter 100mm.
Install the Air outlet joint
Please use 2 self‐tapping screws (Φ4*16mm) to fix the air outlet joint in the
ceiling of the fixed box.
Air outlet joint
Install the Main Body
Please put the main body directly face the guide slot of the air outlet joint,
then push up the main body.
Please ensure that the main body joined to the air outlet joint, then use 8
subsidiaries of the tapping screws (diameter 4*25mm) to fix the main body.
The minimum distance between the surrounding structures should be 50 cm.
Over 50cm to the wall
B
C
2 Self-tapping
screw(φ4*16mm)
‐ 8 ‐
Over 5cm
Screw hole 1,2,3,4,5,6,7,8 for ceiling joist installation
Screw hole A,B,C,D for suspended ceiling installation
Screw hole 1,2,3,4,5,6,7,8 for window installation
Main Body Air outlet joint
Exhaust pipe
Downdip 1°-2°
Self-tapping
Inspection opening
screw(2 pieces)
Front Panel
380