Sloan CX Series Installation Instructions Manual

Sloan CX Series Installation Instructions Manual

Manual closet and urinal flushometers

Advertisement

Quick Links

SLOAN CX MANUAL CLOSET AND URINAL FLUSHOMETERS
Sloan Valve Company warrants its Flushometer to be made of first class materials, free from defects of material or workmanship under
normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of
three (3) years (one year for special finishes) from the date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts
that prove to be thus defective if returned to Sloan Valve Company, at customer's cost, and this shall be the sole remedy available under this warranty. No claims will
be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations that purchase Sloan Valve Company's products
directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of batteries.
THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSE-
QUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
PRIOR TO INSTALLATION
This valve is designed for new construction or where there is easily accessed plumb-
ing for the fixture and valve. This valve is designed for a minimum 6-1/2 inch (165
mm) wall space depth. Distance from the center of the valve (inlet or outlet pipe) to
the finished surface of the wall can vary from 3-1/4" – 4-1/4" (83 – 108 mm).
TOOLS AND ITEMS REQUIRED FOR INSTALLATION (PROVIDED)
• 9/64" hex wrench • Wall plate depth guide • Adjustment tool
TOOLS AND ITEMS REQUIRED FOR INSTALLATION (NOT PROVIDED)
• Smooth-jawed wrench (at least 2") • Philips screwdriver • threaded sweat solder adapter
• approximately 15"-18" pipe
ITEMS INCLUDED (VALVE BOX)
1. Valve Assembly
2. Mud Guard
3. (2) #10-32 x 2 1/2" screws to
secure mud guard
4. (2) 1/4" x 20 x 2" screws to
remove activation assembly
5. Adjustment tool
6 Installation instructions
7. Holder Tool
8. Adjustable tube
9. Outlet connection
10. Elbow
11. Inlet adapter
12. Vacuum Breaker
13. Couplings & gaskets
INSTALLATION INSTRUCTIONS FOR
Manual Closet Flushometers
Model CX 158-1.6
Model CX 158-1.28
Model CX 154-1.6
Model CX 154-1.28

LIMITED WARRANTY

1. Valve Assembly
8. Adjustable
9. Outlet
Tube
Connection
Manual Urinal Flushometer
Model CX 198-0.5
Model CX 198-0.25
Wall plate opening must be a minimum of 7-3/8" wide x 8-3/8" tall (187 mm wide
x 213 mm tall) to maximum 7-5/8" wide x 8-5/8" tall (194 mm wide x 219 mm
tall). Mud plate is provided and must accompany valve for proper installation. Mud
plate is removed after wall is finished.
2. Mud Guard
3. #10-32
Mud Guard Screws
6. Installation
Instructions
10. Elbow
11. Inlet
Adapter
1
4. 1/4-20 Activation
Assembly Screws
7. Holder Tool
12. Vacuum Breaker
13. Couplings & Gaskets
Assembly V-651A Kit
Code No: 0816856
Rev. 2 (8/19)
5. Adjustment
Tool & Holder

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Sloan CX Series

  • Page 1: Limited Warranty

    (3) years (one year for special finishes) from the date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts that prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty.
  • Page 2 • WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE. • FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS. Sloan’s flushometers are designed to operate with 20 to 80 psi (138 to 552 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED.
  • Page 3 ROUGH-IN CLOSETS Rough-in for Sloan CX is determined relative to the spud connection for the fixture being used. SIDE VIEW FRONT VIEW MODEL 158 CLOSET WALL !!! IMPORTANT !!! HUNG REAR INLET ACCURACY IS IMPORTANT FOR WALL OPENING Rear of valve to fin. wall DIMENSIONS.
  • Page 4: Parts Overview

    PARTS OVERVIEW Plunger Plunger Screw Mounting Bracket Screws Depth Guide Mud Guard Button 9/64” Hex Anti-vandal screw Wrench Wall Plate Valve Body Wall Plate to Metal Mounting Mounting Bracket C-bracket bracket to valve body screws Shut-off Sleeve (integrated control stop) Piston Assembly Vacuum Breaker...
  • Page 5 Connect 1 1/2” to 1 “ adapter into top of flushometer (“IN”) Tighten fittings securely into valve body with a fixed jaw wrench. 15”-18” NOTE: PROPERLY BRACE SUPPLY PIPE AFTER SWEATING CONNECTIONS TO PREVENT VALVE MOVEMENT DURING INSTALLATION AND USE SLOAN RECOMMENDS BRACING VALVE WITHIN 6" OF INLET CONNECTION.
  • Page 6 MAKING SPUD CONNECTION CONFIGURE ADJUSTABLE TUBE If needed, trim bottom of adjustable tube using grinding style cut-off Finish wall. Use supplied mud guard to protect valve during finishing tool. process. • NOTE: would only be needed for certain ADA • Use two (2) mounting bracket to valve body screws, if needed, water closet installations.
  • Page 7 FOR FLOOR MOUNT REAR SPUD FIXTURES (WATER CLOSET) If needed, trim bottom of adjustable tube using grinding style cut-off Install mud guard. Finish wall. tool. Mount fixture. • NOTE: would only be needed for certain ADA Loosen vacuum breaker to valve. Pull flush water closet installations.
  • Page 8 FLUSHING WATER LINES Note: Valve is shipped with flow adjustment turned off. Once lines are flushed clear, turn activation assembly clockwise to Shut off water: use adjustment tool to turn activation assembly fully clockwise. shut off water. CLOSE CLOSE Relieve pressure by pressing plunger. Push in activation assembly. Push in activation assembly.
  • Page 9 ADJUSTING FLOW Using adjustment tool, turn activation assembly slowly to adjust flow. i.There is approximately 1/8-turn (45°) of free spinning as the activation assembly engages the shut-off sleeve between opening and closing the valve. ii. 1-1/2" socket or wrench can be attached to the adjustment tool or a screwdriver can be passed through the side side holes to provide additional torque.
  • Page 10 INSTALL WALL PLATE ASSEMBLY (CONT.) Tighten #8-32 screws at bottom of wall bracket. Metal C-bracket Choose one of three Plunger screws and nut provided and thread will clamp against wall. into plunger. If Plunger starts rotating, STOP. This means the screw has reached the bottom of the hole and overtightening the screw will cause damage to the plunger.
  • Page 11: Basic Servicing

    BASIC SERVICING Open wall plate i. Loosen set screw using 9/64 allen key ii. Lift button until it snaps into the "up" position CLOSE Remove wall plate. Loosen two screws, pull forward. Note: water can be shut-off without removing wall plate. Removing wall plate provides more hand room for servicing valve.
  • Page 12: Troubleshooting Guide

    TROUBLESHOOTING GUIDE 1. Flushometer does not function (no water/flush). A. Ensure water supply to valve is turned on. B. Shut off sleeve is in closed position. Turn counterclockwise to open water flow. NOTE: There is approximately 1/8-turn (45°) of free spinning as the activation assembly engages the shut-off sleeve between opening and closing the valve.
  • Page 13 For Model 8198 The information contained in this document is subject to change without notice. SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131 Phone: 1.800.982.5839 or 1.847.671.4300 • Fax: 1.800.447.8329 or 1.847.671.4380 • sloan.com COPYRIGHT © 2019 SLOAN VALVE COMPANY...

Table of Contents