The F-Link software saves (3 to 10 in the Installation Information window) the history of settings backwards
in its own database. This history of settings is used by the software for upgrades of the control panel firmware
as a change always causes the loss of the previous settings and this history can be used to restore it.
The same option can be used in the case of a Reset of the control panel to the default settings, replacement
of the SD card, language changes when texts are deleted, which can be restored this way or just in the case
of an inadvertent change of a setting.
12 Reset of the control panel
You can only restore the default settings of the control panel in the following way if in the F-Link SW
in the Parameters tab the Reset allowed item is checked. If Reset is not allowed and you do not know
the service code, you cannot reset the control panel and the control panel board must be sent to the distributor.
Procedure:
1.
Switch the control panel to the Service mode (not obligatory)
2.
Open the control panel cover: Reset requires that the tamper contact must be active. If the condition
of point 1 was not fulfilled, an alarm will be released.
3.
Disconnect the USB cable from the control panel.
4.
Turn off the power supply (most easily by releasing the power supply fuse) and disconnect the battery.
5.
Connect the pins on the control panel board marked RESET (using the jumper included in the delivery).
6.
First connect the battery and then the power supply of the control panel and wait. The green, yellow and
red signal lamp at the jumper will light up (if just the red signal lamp will remain on, the setting Parameters
/ Reset Allowed is not enabled).
7.
Wait for approx. 5 s and then disconnect the jumper.
8.
After 5 s all signal lamps will flash as a confirmation of completion of the control panel reset.
Then, voltage restart of the control panel and BUS devices will occur, which will be confirmed by a flash
of all segments on the keypads.
9.
This way, the control panel has been reset to the default settings, incl. language selection. However,
reset of the control panel does not cause deletion of the history of events saved on the memory SD card.
If Reset was not executed correctly, the control panel will keep the original settings without changes.
JA-101K(-LAN)(-LAN3G) and JA-106K(-3G)
Security System Control Panels
100 / 110
MLJ51410
Need help?
Do you have a question about the JA-101K and is the answer not in the manual?
Questions and answers
Jablotron JA-106K-3G Lähetätkö akun vaihdon ohjeet.
To replace the battery in the Jablotron JA-101K:
1. Switch off the mains power supply.
2. Open the control panel housing.
3. Disconnect the battery supply leads (note polarity: red +, black -).
4. Remove the old battery from the housing.
5. Insert the new battery and fix it using self-sticking blocks or a strap.
6. Connect the supply leads to the new battery, ensuring correct polarity.
7. Close the housing.
8. Switch on the mains power and check the LED indicators.