ERROR CODE
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
8 flashes
9 flashes
10 flashes
11-12 flashes
13 flashes
14 flashes
14 flashes
9M02-7608-A001-EN
Version 2.0
ERROR
Transkey cannot be read
Transkey configuration
fault
Fault during voltage
monitor test
Fault with the safety relays
(not used)
Fault with RF module
General system error
Relay control voltage is
too low
Hardware fault
(not used)
Slave CAN controller
cross-monitor error
Master CAN controller
cross-monitor error
Rotary switches invalid
setting
ACTION
Make sure the Transkey is in place
Verify Transkey configuration is coherent with the actual
hardware; for example, module selected is not the same as
the one installed
Send to Cattron for repair
Send to Cattron for repair
Replace the RF module
Send to Cattron for repair
Send to Cattron for repair
Send to Cattron for repair
Make sure both master and slave CAN interfaces are
properly connected to the CAN bus
Make sure both master and slave CAN interfaces are
properly connected to the CAN bus
Make sure switches SW1 to SW3 are set to valid positions