JAG
USER'S AND INSTALLER'S MANUAL
V4.1
REV. 04/2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JAG400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Motorline professional JAG400

  • Page 1 USER’S AND INSTALLER’S MANUAL V4.1 REV. 04/2018...
  • Page 2: Table Of Contents

    00. CONTENT 01. SAFETY INSTRUCTIONS INDEX STANDARDS TO FOLLOW 01. SAFETY INSTRUCTIONS ATTENTION: STANDARDS TO FOLLOW 02. PACKAGE This product is certified in accordance with European Community INSIDE PACKAGE (EC) safety standards. 03. OPERATOR TECHNICAL SPECIFICATIONS This product complies with Directive 2011/65/EU of the European UNLOCK MOTOR Parliament and of the Council, of 8 June 2011, on the restriction of 04.
  • Page 3: Safety Instructions

    01. SAFETY INSTRUCTIONS 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW STANDARDS TO FOLLOW • It is important for your safety that these instructions are followed. • Before installing, the installer must verify that the equipment to be automated • Keep these instructions in a safe place for future reference. is in good mechanical condition, correctly balanced and opens and closes •...
  • Page 4: Package

    INSIDE PACKAGE TECHNICAL SPECIFICATIONS JAG specifications are as follow: In the package you will find the following components: 01 • 02 swing operators JAG400 JAG600 02 • 01 Control Board 03 • 02 remote controls (4 channels) 230V 230Vac 50/60Hz 230Vac 50/60Hz 04 •...
  • Page 5: Installation

    03. OPERATOR 04. INSTALLATION TECHNICAL SPECIFICATIONS VERTICAL INSTALLATION DIMENSIONS JAG 400 || 600 dimensions are the following: Operator must be installed with a small inclination , to prevent water infiltration through the extension arm. For this, the front support must be fixed to the gate with a height lower than the height of the rear support.
  • Page 6: Horizontal Installation Dimensions 5A

    04. INSTALLATION 04. INSTALLATION HORIZONTAL INSTALLATION DIMENSIONS HORIZONTAL INSTALLATION DIMENSIONS On the Illustrated diagrams below and on the next page, are the horizontal dimensions EXTERIOR OPENING for the installation of the automated system. INTERIOR OPENING *Opening mechanical stopper Opening direction (EXTERIOR) Axis of rotation of the motor, on the front bracket...
  • Page 7: Installation Steps

    04. INSTALLATION 04. INSTALLATION INSTALLATION STEPS INSTALLATION STEPS Pay attention to the installation dimensions mentioned on pages 03B, 04A and 04B! 03 • Test the movement. • Install the pins removed earlier on each side with a small amount of lubricant for less friction.
  • Page 8 04. INSTALLATION 04. INSTALLATION MICROS ADJUSTMENT MICROS ADJUSTMENT 01 • Unlock the motor (see page 3A). 06 • Take the gate to the open position. 02 • Loosen the 3 front screws, remove the cover and the profile cover. 07 • Loosen the screw shown in the image (24), so that it is possible to move the micro-switch in the profile.
  • Page 9: Installation Map

    04. INSTALLATION INSTALLATION MAP CONTROL WARNING MOTOR BOARD LAMP ANTENNA SELECTOR EXTERIOR PHOTOCELLS JUNCTION BOX EXTERIOR INTERIOR PHOTOCELLS PHOTOCELLS GATE STOPPER LEGEND: Connection cables It is important to use mechanical stoppers in the opening and closing position of the gate. It is important to use junction boxes for connections between motors, components and If not respected, components of the automation may suffer efforts for which they were not control unit.
  • Page 10: Connection Scheme

    06. COMPONENTS TEST 05. CONNECTION SCHEME 110V/230V MOTOR 24V MOTOR To detect which are the components with problems in a 24V JAG automatism installation, it is necessary to conduct tests with a direct connection to a external power supply (bateria 24V). In the scheme below is shown how it should be done this link.
  • Page 11: Motor A 230V/110V

    06. COMPONENTS TEST 230V/110V MOTOR To detect if the malfunction is on the control board or on the motor All tests must be performed by qualified per- NOTES: is, sometimes, necessary to perform tests with connection directly sonnel due to serious danger associated with •...
  • Page 12: Maintenance

    07. MAINTENANCE MAINTENANCE • Clean stainless steel arm • With a cloth soaked in lubricant spray, wipe any residue that accumulates on the opera- tor’s stainless steel arm. • Apply a small amount of spray lubricant on the arm and using a dry cloth remove the ex- cess, leaving a homogeneous layer of lubri- cant over the arm.
  • Page 13: Troubleshooting

    08. TROUBLESHOOTING FINAL CONSUMERS INSTRUCTIONS INSTRUCTIONS FOR SPECIALIZED INSTALLERS Anomaly Procedure Behavior Procedure II Discovering the origin of the problem 1 • Open control box and check control board and test them by problem is on the control board. remove them from installation •...