00. CONTENT 01. SAFETY INSTRUCTIONS INDEX STANDARDS TO FOLLOW 01. SAFETY INSTRUCTIONS ATTENTION: STANDARDS TO FOLLOW This product is certified in accordance with European Community (EC) safety standards. 02.PACKAGE INSIDE PACKAGE This product complies with Directive 2011/65/EU of the European Parliament and of the 03.
02. PACKAGE 03. OPERATOR INSIDE PACKAGE CHANGE MOTOR DIRECTION In the package you will find the following components: The operator LINCE, is a product developed exclusively for the automatic opening of swing gates. 01• 02 Swing operators LINCE 02• 01 Control Board Besides being pratical, safe and powerful, this product has a new function incorporated 03•...
Page 4
03. OPERATOR 03. OPERATOR CHANGE MOTOR DIRECTION UNLOCK OPERATOR 03 • Loosen the screws of the Middle Part 04 • Remove Middle Part 01 • Remove the plastic cap from the rear Information engraved on the unlock shaft D=Unlock || B=Lock 05 •...
03. OPERATOR 04. INSTALLATION TECHNICAL SPECIFICATIONS VERTICAL INSTALLATION DIMENSIONS The operator LINCE must be installed with a small inclination , to prevent water LINCE300 LINCE400 LINCE600 infiltration through the extension arm. 230V AC 230V 50/60Hz AC 230V 50/60Hz AC 230V 50/60Hz For this, the front support must be fixed to the gate with a height lower than the height •...
Page 6
04. INSTALLATION 04. INSTALLATION VERTICAL INSTALLATION DIMENSIONS HORIZONTAL INSTALLATION DIMENSIONS On the Illustrated diagrams below and on the next page, are the horizontal dimensions for the installation of the automated system. INTERIOR OPENING EXTERIOR OPENING Axis of rotation of the (EXTERIOR) Opening mechanical stopper motor, on the front bracket...
Page 7
04. INSTALLATION 04. INSTALLATION INSTALLATION STEPS INSTALLATION STEPS 04 • Install operator on the supports Pay attention to installation dimensions mentioned on pages 04B, 05A and 05B! • The operator must be placed on both supports the same time to avoid leaving the operator suspended by only one of the supports.
04. INSTALLATION INSTALLATION MAP • INTERIOR • EXTERIOR • MOTOR LINCE • EXTERIOR • KEY • WARNING • ANTENNA • CONTROL PHOTOCELLS PHOTOCELLS PHOTOCELLS SELECTOR LAMP BOARD • JUNCTION LEGEND: • Connection cables It is important to use mechanical stoppers in the opening and closing position of the It is important to use junction boxes for connections between motors, components gate.If not respected, components of the automation may suffer efforts for which they and control unit.
05. TROUBLESHOOTING FINAL CONSUMERS INSTRUCTIONS INSTRUCTIONS FOR SPECIALIZED INSTALLERS Anomaly Procedure Behavior Procedure II Discovering the origin of the problem • Motor •Make sure you • Still not working • Consult a qualified 1 • Open control box and check 3 •...
06. COMPONENTS TEST 06. COMPONENTS TEST 230V/110V MOTOR 24V MOTOR To detect which are the components with problems in a 24V LINCE automatism To detect if the malfunction is on the control board or on the motor is, sometimes, instalation, it's sometimes necessary to run a test directly to a external power supply necessary to perform tests with connection directly to a 110V/230V power supply.
07. MAINTENANCE 07. MAINTENANCE MAINTENANCE MAINTENANCE • Clean stainless steel arm • Check motor supports • With a cloth soaked in lubricant spray, wipe any residue that accumulates on the •Make sure that supports remain well fixed on the pillars and gate to ensure proper operator’s stainless steel arm.
Need help?
Do you have a question about the LINCE Series and is the answer not in the manual?
Questions and answers