Maintenance; Preventive Maintenance Schedule - Atlas Copco LFx 0.7 Instruction Book

Oil-free air piston compressors
Table of Contents

Advertisement

Instruction book
5

Maintenance

5.1

Preventive maintenance schedule

Warning
Warranty-Product Liability
Use only genuine parts. Any damage or malfunction caused by the use of unauthorised parts is not covered
by Warranty or Product Liability.
General
When servicing, replace all removed gaskets, O-rings and washers.
Intervals
Carry out maintenance at the interval which comes first. The local Atlas Copco Customer Centre may overrule
the maintenance schedule, especially the service intervals, depending on the environmental and working
conditions of the compressor.
The "longer interval" checks must also include the "shorter interval" checks.
Preventive maintenance schedule
Running hours
Daily
"
100
4000
5000
2920 7002 03
Before carrying out any maintenance, repair work or adjustments, proceed as
follows:
Stop the compressor.
Switch off the voltage and open the isolating switch.
Close the air outlet valve and open the manual condensate drain valve.
Depressurise the compressor.
For detailed instructions, see
The operator must apply all relevant
Operation
Drain the condensate from the receiver.
Keep the unit clean.
Inspect the inlet air filter pad, replace if necessary. When operating in dusty surroundings,
replace the filter more frequently.
For units running at 10 bar (145 psi) a general overhaul of the unit is recommended.
For units running at 7 bar (100 psi) a general overhaul of the unit is recommended.
A general overhaul includes the replacement of the motor and the compressor element.
Problem
solving.
Safety
precautions.
33