Bien Air CA 1:1 Instructions For Use Manual
Hide thumbs Also See for CA 1:1:

Advertisement

Quick Links

CA 1:1
EVO.15 1:1
CA 1:5
EVO.15 1:5
CA 10:1
ENG Instructions for use
other languages available on
www.bienair.com/ifu
0120
REF 2100294-0001/2019.08

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CA 1:1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bien Air CA 1:1

  • Page 1 CA 1:1 EVO.15 1:1 CA 1:5 EVO.15 1:5 CA 10:1 ENG Instructions for use other languages available on www.bienair.com/ifu 0120 REF 2100294-0001/2019.08...
  • Page 2 1600386-001 1600325-001 1600690-001 1600941-001 1600940-001 Set supplied (REF) CA 1:1 1600384-001 1600424-001 1600691-001 1600939-001 1600938-001 Set supplied (REF) CA 10:1 1600385-001 1600425-001 Optional accessories (REF) 1600036-006 1600064-006 1000001-010 REF 2100294-0001/2019.08 CA 1:1, 1:5, 10:1, EVO.15 • © Bien-Air Dental SA...
  • Page 3: Table Of Contents

    Table of contents 1 Symbols.......... 2 6.5 Sterilisation ........10 6.6 Servicing ........10 1.1 Description of symbols used ..2 7 Packing and disposal....11 2 Identification & Intended Use ..3 7.1 Transport and storage 2.1 Identification ........3 conditions ........11 2.2 Intended use ........3 7.1.1 Packing .......
  • Page 4: Symbols

    ENG Instructions for use 1 Symbols 1.1 Description of symbols used Symb Description Symb Description Manufacturer. Reference number. CE Marking with number of the noti- Serial number. fied body. 0120  Electrical or electronic materials to CAUTION! be recycled. Refer to the accompanying Recyclable materials.
  • Page 5: Identification & Intended Use

    This product is intended solely for pro- & Intended Use fessional use. For use in dentistry: 2.1 Identification • CA 1:1, CA 10:1 and EVO.15 1:1: for prophylaxis, restoration and endo- Medical devices made entirely in Switzer- dontic procedures. land by Bien-Air Dental SA.
  • Page 6: Precautions For Use

     CAUTION 3 Precautions Any excess maintenance product (lubri- cant, cleaning and disinfection prod- for use ucts) present on the contra-angle could find its way into the electric brush This medical device accessory must be motor and adversely affect its opera- used by a competent person, in particu- tion.
  • Page 7: Description

    135°C 135°C FIG. 1 (EVO.15 1:1 L) 4 Description 4.1 Overview FIG. 1 (1) Centring for the micromotor (2) Light outputs (3) Bur (not supplied) (4) Transmission ratio marking strip (5) Push-button 4.2 Technical data Transmission ratio 10:1 Standard coupling As per ISO standard 3964 and Micro-Series version.
  • Page 8: Assembly And Operation

    Type 1 / ISO 1797 min. 12 mm Code 4 / ISO 6360-1 max. 22 mm Type 3 / ISO 1797 min. 12 mm Code 4-5 / ISO 6360-1 max. 21 mm FIG. 3 FIG. 2 3. Check it is correctly locked by gently pushing and pulling the bur.
  • Page 9: Cleaning And Servicing

    6.1.2 Suitable maintenance products 6 Cleaning and Automatic cleaning-disinfection: servicing • Low alkaline or enzymatic detergent recommended for cleaning in a washer-disinfector for dental or sur- 6.1 Maintenance gical instruments (pH 6 - 9.5). Manual cleaning/disinfection Clean, lubricate and sterilise the device separately between patients.
  • Page 10: Preliminary Cleaning

    EVO.15 CA 1:1, 1:5, 10:1 FIG. 4 FIG. 5 6.2 Preliminary cleaning 6.2.2 Preliminary bath cleaning  CAUTION Preparation The preliminary bath cleaning should be FIG. 4 followed by automatic cleaning-disinfec- tion. 1. Disconnect the coupling device, 1. Totally submerge the device in a remove the bur (FIG.
  • Page 11: Cleaning-Disinfection

    FIG. 6 6.3 Cleaning-disinfection Washer-disinfector Carry out automatic cleaning-disinfec- 6.3.1 Manual cleaning/disinfection tion using an approved washer-disin- 1. Dip the device in a tank containing fector which complies with appropriate detergent and, using a soft standard 15883-1 (e.g. Miele G 7781/G brush, clean and disinfect the device, 7881 or Steris Hamo LM-25).
  • Page 12: Lubrication

    FIG. 8 FIG. 7  6.4 Lubrication CAUTION Do not use a sterilisation procedure 6.4.1 Verifying cleanliness other than the one described below. Visually inspect the device to ensure it Procedure is clean. If necessary, clean again using Enclose the device and its accessories in a soft brush.
  • Page 13: Packing And Disposal

    50 kPa and 106 kPa. The warranty period is: • 12 months for the CA 10:1 range 7.1.1 Packing • 24 months for the CA 1:1, CA 1:5 Pack the instrument in packaging and EVO.15 ranges approved for steam sterilisation.
  • Page 14: References

    1600384-001 CA 1:1 L (light) 1600424-001 CA 1:1 (without light) 1600385-001 CA 10:1 L (light) 1600425-001 CA 10:1 (without light) 1600691-001 CA 1:1 L Micro-Series (light) 1600386-001 CA 1:5 L (light) 1600325-001 CA 1:5 (without light) 1600690-001 CA 1:5 L Micro-Series (light)
  • Page 15 REF 2100294-0001/2019.08 CA 1:1, 1:5, 10:1, EVO.15 • © Bien-Air Dental SA...