8.4
Re-fi lling / Changing Aroma and aquaCool
Gel: SUNRISE and
DAYDREAMS /
aquaCool
Step
1
Open the lower front cover and regularly
check the fi lling level of the water tank
and of the aroma tin. When the content of
one of the container has been used up,
replace the corresponding container.
2
Pull the holding element of water tank and
aroma tin forward. .
3
Move the covering handle on the lid of the
aroma tin to the left (1) and then move the
lid upward (2). Now you can replace the
tin.
4
Unscrew the lid with the hoses from the
tank and replace the empty tank by a full
one. Screw the lid on again.
Keep clean the end of the tubes when
changing the tank (use a plastic bag).
Only use the specifi c water by KBL
„aquacool". Otherwise the nozzles may
48
clog up which might produce infections.
5
Put the constructional elements back into
their original place in the sunbed.
6
Acknowledge the error message in
service level I by calling up the displays
shown on the right and by pressing key 1.
Operation and Service megaSun 7900
The gel tin and the water tank are in the base part between the
air-conditioning unit (on the left) and the electronics system (on
the right
Procedure
Reference
2