Setup and Operation
PORT Menu⎯Setting Logical Non-Ethernet Input Ports
To set logical non-Ethernet input ports:
1
Select the PORT option on the MAIN menu.
2
Select a logical non-Ethernet input port (1 through 16) at the PORT ##: prompt.
3
Select PIDTBL and then press
4
Select ERASE and COMMIT if setting up a new PID Table. This ensures that any previous
settings are cleared.
5
Select CONFIG and then press
Figure 4-15.
6
Select a PIDTBL entry from 01 to 28.
7
Select the PID-IN> number (0000H to 1FFFH); for Entry number 2 through 28 only.
8
Select the PID-OUT> number (0000H to 1FFFH) for Entry number 2 through 28 only.
9
At the DST-PORT> prompt, select the first, second, and third destination output ports
(00 through 16).
Entry 01 is for default PIDs not otherwise identified by the PID table.
Figure 4-15
PIDTBL setup menu
A
D
Table 4-12 describes the fields and available options:
Table 4-12
PID table setup menu options
Key
Field
Options
A
PIDTBL nn
01
through
28
B
PID-IN
0000H
through
1FFFH
C
PID-OUT
0000H
through
1FFFH
OM 1000 Installation and Operation Manual
. If setting up an existing PID table, skip to step 5.
ENT
to display the PIDTBL setup menu illustrated in
ENT
B
E
F
Description
Selects a port nomenclature.
Specifies the hexadecimal PID number to which this map applies.
Press
or
to move from digit to digit or change the digits. This is not
displayed on the menu for PID table entry number 01.
Specifies the hexadecimal number to which the specified input PID is
re-assigned for output. Press
digits. This is not displayed on the menu for PID table entry number 01.
C
G
H
or
to move from digit to digit or change