Page 4
List of abbreviations – power supply – fire alarm – remote control – access control system – operating device (turnstile) – normally connected – normally opened Speedgate firmware version FW v2.0-2.2 Card collector firmware version FW v1.52 Praktika T-05(K) speedgate...
1. Basic specifications Table 1 Basic specifications Description Speedgate RC panel Dimension of side unit with open wings 1050х1500х200 107х107х25 (mm) (HхWхL) Dimension of side unit depending on passage lane (mm) 107х107х25 1050х1500х500 1050х1500х620 Weight of side unit depending on passage lane, kg 110,0 113,0...
Additionally the card collector can be integrated in the design of the speedgate. Base covers for access to PU, RC and ACS cables holes (Fig. 1) are provided at the bottom of side units. Praktika T-05(K) speedgate...
Page 7
Speedgate may have only a single passage, however an unlimited number of passages can be arranged with the use of side units and middle units, depending on customer requirements. Fig. 1 General view of speedgate LED panel Display panel of the speedgate is made of artificial stone with an insertion made of acrylic glass.
Page 8
The housing of RC panel is made of polished stainless steel. On the front side there are control buttons and LED indicators of RC operational modes (Fig. 3). The standard supplied cable is 5 m long. Fig. 3 General view of remote control panel Praktika T-05(K) speedgate...
3. Safety requirements CAUTION! Failure to comply with the safety requirements specified in this section may result in damage to human life and health, total or partial loss of workability of products and (or) auxiliary equipment. CAUTION! The producer disclaims any liability for damage to human life and health, total or partial loss of workability of products and (or) auxiliary equipment for non-compliance of the safety requirements specified in this section, as well as terminates the product warranty.
4.2. Installation of speedgate CAUTION! We recommend to mark the mounting holes corresponding to side unit base holes when the wings are already installed. CAUTION! During installation take into account that glass wings cannot be adjusted. It is recommended to check the correctness of installation before fixing the side units.
Page 12
CAN-Bus, and, if provided, cables of FA and ACS into cable channel or conduit. 4.2.7. Set the side units of speedgate on a prepared site. Unscrew the 4 units of M4 screws and remove the base cover (Fig. 5). Praktika T-05(K) speedgate...
Page 13
4.2.8. Put housing cables of RC, PS, CAN-bus and, if necessary, cables of FA and ACS inside speedgate housing. Secure cables with cable ties. Fig. 5 Installation diagram of side unit 4.2.9. Align together the holes in the lower plate of side unit and anchors in the floor.
Figure 6 shows the location of motherboard at the front of the side unit. Fig. 6 Location of motherboard on the side unit Figure 7 depicts the motherboard and connectors for PS, RC, ACS and FA. Praktika T-05(K) speedgate...
Page 15
Fig. 7 General view of motherboard CAUTION (!) Operating mode of speedgate is defined by setting the jumpers on motherboards of both side units of the speedgate. Table 3 Operating mode of speedgate The position of jumpers Operating mode of speedgate J1 removed Pulse mode (see article 5.3.) J1 installed...
Make sure the cables are securely connected. 5.2. Connecting remote control panel RC panel is connected to Control Board contact set on motherboard. When the first side unit is connected second side unit shall be connected in Praktika T-05(K) speedgate...
parallel to it using the routed signal cable of CAN-Bus. Marking of contacts: 12V, CL, CH, GND. Table 4 Marking of PS contacts Contacts marking Wire color Yellow Green Blue 5.3. Connecting side units Connecting pattern for two side units is shown in Fig. 8. In case you need to increase the number of passes, it shall be cascaded Installation guidelines...
Page 18
For normal operation of the entrance with two passages, perform the following: combine two side units (A and C) and one middle unit B, with two three-wire buses CAN-2 (first bus CAN2.0 and second bus CAN2.0). See Fig. 8. Praktika T-05(K) speedgate...
Connect «CL» «CH» «GND» contacts of motherboard located in unit "A" housing (marked No. 1) with the same contacts of motherboard located in unit B housing (marked No. 4). See Fig. 8. «CL» «CH» «GND» contacts of motherboard located in unit “B” (marked No.
Page 20
ACS has a higher priority. AP and STOP inputs operate only in a potential mode (as potential and constant), i.e. as long as the input is closed on GND contact the Praktika T-05(K) speedgate...
Page 21
speedgate operates in corresponding mode. When contacts are open - speedgate switches to the "Stop" mode irrespective to the mode of operation that was used before ACS operation. LEFT and RIGHT inputs can operate both in potential and in pulse modes (responding upon GND contact closure).
Page 22
5. The numbering of the remote control buttons is shown in Fig. 9. The maximum output current for this set of contacts is 150 mA, maximum voltage rating is 24 W. Fig. 9 Numbering of the remote control buttons Praktika T-05(K) speedgate...
Page 23
Table 6. I/O contact set assignment Contacts Contacts assignment marking I/O1 "Left" button status (1,0) I/O2 "Right" button status (3,0) I/O3 "Stop" button status (2, Fig.10) I/O4 "Antipanic" button status (4,0) I / O1 ... I / O3 outputs show the current status of the RC panel buttons, i.e.
Page 24
RC panel buttons (except for the free passage in the potential control mode. See article 5.3 of Manual). In this case ACS controls these operation modes. Fig. 11 Connection pattern of RC panel to ACS controller Praktika T-05(K) speedgate...
6. Connecting card collector 6.1. Card collector description In front of the housing there is a hatch with lock for quick access to collected cards and to the board when PS, OD and ACS cables are connected (fig. 13). The hatch includes a card storage device. ATTENTION (!) Card reader is not included in the delivery set.
Page 26
Fig. 12 General view of the card collector Fig. 13 shows general view of board and connectors for PS, EU and ACS. Praktika T-05(K) speedgate...
Fig. 13 General view of card collector board 6.2. Connecting power supply Card collector is powered by a 12 V DC voltage source. Maximum consumption is present in the mode of card collection - 1.5A. Locate the PS unit to be accessible for operator. Connect PS cable to the card collector board.
Pass Ok and GND), confirming the passage, is received, the card collector switches into standby mode and can collect the next card. For these reasons, the connection of this contact set is essential to the system capacity. Praktika T-05(K) speedgate...
6.4. Connecting ACS controller ACS controller is connected to one speedgate unit only. The connection between units is provided by CAN-bus. Block diagrams of ACS controller with the use of card collector are shown in Appendix 3. Connection of ACS controller to the card collector provided by three contact sets: "Take Card-GND"...
Page 30
Potential mode of the speedgate is not provided, the card collector shall be set to pulse mode. In order to switch into pulse mode: • Turn off the power • Wait until LED D11 turns off Praktika T-05(K) speedgate...
• Press and hold BUT1 button on the card collector board • Turn on the power; • Press and hold BUT1 button until the card collector provides 1 audio signal, indicating that it is switched to pulse mode of operation; Set mode is saved when power is turned off.
Page 32
(5, Fig. 15). Tighten the M3 screw (6, Fig. 15). 6.5.6. Fix the bracket to clips (7, fig. 15) using the M4 screws (8, Fig. 15). It is recommended to install a reader at an angle of 40 ... 50º to Praktika T-05(K) speedgate...
Page 33
guiding bars for cards (Fig. 16). In this case, the guest and permanent card will be read equally well. 6.5.7. Put the cable of reader in the housing of the card collector. 6.5.8. CAREFULLY (!) set the LED panel in its original position.
The standard RC panel is equipped with such resistor on default. If you use one RC panel it is recommended to connect an additional (second) 120 ohm resistor mounted on the Praktika T-05(K) speedgate...
Page 35
motherboard to CL and CH terminals. It is connected with the use of J4 jumper. Installation process is described in article 5.3 (Connecting side units). It is not required, however, in case of connection of two RC panels, because required 120 ohm resistors are already installed at the ends of the bus (in RC panels).
Page 36
1* and 2* are drawn by dotted lines. This scheme features two readers. The second reader shall be installed outside the card collector, which is not always aesthetically and practically acceptable. If installed close to each other, proximity readers can create mutual interference. Praktika T-05(K) speedgate...
Page 37
Fig. 19 Block diagram №2 Fig. 19 shows a more advanced but also a more high-cost circuit connection. The advantage of this scheme is that it uses only one reader installed in the card collector. Wiegand interface provides a possibility to connect several identical ACS controllers to one reader in parallel.
Page 38
#2. It reduces the cost of installed system. For this purpose the controller with two output signals to one input of a reader (i.e., the controller can distinguish the guest cards and permanent cards transmitting a signal to the corresponding output) is used. Praktika T-05(K) speedgate...
Appendix 3. Location of mounting holes in relation to the overall dimensions of the speedgate Fig. 21 Location of mounting holes in relation to the overall dimensions of the speedgate Installation guidelines...
Page 40
Fig. 22 Dimensions of speedgate depending on passage lane (top view) Praktika T-05(K) speedgate...
Appendix 4. Block diagram of minimal connections for synchronized operation of wings with the use of one RC panel Fig.23 Block diagram of minimal connections for synchronized operation of wings In order to secure stable operation of the speedgate unit one GND terminal of one unit shall be connected to another GND terminal of another speedgate unit.