Page 4
List of abbreviations – power supply – fire alarm – remote control – access control system – operating device Speedgate firmware version FW v1.4-2.2 Card collector firmware version FWv1.52 Praktika T-05(K) speedgate...
1. Product purpose Praktika T-05 speedgate is designed for access control and pedestrian flow management. The speedgate can be used at checkpoints at factories and organizations, institutions, banks, schools, sports and entertainment facilities, shops, railway stations, etc. To ensure easy and quick passage of people it is recommended to install one speedgate for every 500 people working in one shift.
Temperature range, operation +1...+40 +1...+40 - transportation and storage +1...+40 +1...+40 Atmosphere relative humidity, no more than % Throughput, people per minute Card collector capacity (pcs.) More than 500 Max. number of connected RC panels, pcs Lifetime, years Praktika T-05(K) speedgate...
Table 3 Electrical specifications Description Speedgate Card collector** RC panel Supply voltage, V: - nominal 12,0 12,0 12,0 - working 10,8...15,0 7,5...15,0 8…18,0 Average current in standby mode * A Average current operational mode * A Maximal current of 1 side unit*/***, A Maximal current...
Page 8
Display panel of the speedgate is made of artificial stone with an insertion made of acrylic glass. Speedgate operating modes are displayed on the panel in the form of mnemonic signs depicting authorization and non-authorization of passage (Fig. 2). Praktika T-05(K) speedgate...
Page 9
Fig. 2 General view LED panel display Remote Control Panel The housing of RC panel is made of polished stainless steel. On the front side there are control buttons and LED indicators of RC operational modes (Fig. 3). The standard supplied cable is 5 m long. Fig.
1. The sensors are installed in the stands of speedgate at a height of 820 Children shorter than 820 mm cannot be identified by the speedgate. Children must be accompanied by adults in charge when passing through the speedgate! Praktika T-05(K) speedgate...
Page 11
Baggage, carts, bags etc. cannot be identified by the speedgate. 2. If there is no distance in the passage between the two visitors, they might be identified as one. CAUTION! Installation of speedgate must be carried out by qualified personnel according to the instructions. CAUTION! The producer disclaims any liability for damage to human life and health, total or partial loss of workability of products and (or) auxiliary equipment for non-compliance of the safety requirements specified in this...
Flexible logic of the controller allows the integration of the card reader with any access control systems. 7.2. Product design Fig 4. General view of the card collector Praktika T-05(K) speedgate...
In front of the housing there is a hatch with lock for quick access to collected cards and to the board where PS, OD and ACS cables are connected. The hatch has card storage device where more than 500 cards can be stored.
"Stop" mode. Green arrow indicator turns on on the display showing a free passage to the left (right). Green LED indicator on the RC panel turns on above the button corresponding to the authorized passage and a red Praktika T-05(K) speedgate...
indicator - above button 2. If the passage is not perfromed within 5 seconds, the speedgate switches to "Stop" automatically. Free passage mode In order to swich to this mode press and hold button 1, then press button 3 and release both buttons. In this mode an unlimited number of passages is allowed in both directions.
Guest card shall be inserted into the card hole up to the stop otherwise it will be ignored. In case the presented card is authorized, the card collector collects it and then unlocks OD for 5 seconds. Praktika T-05(K) speedgate...
Page 17
Storage device is full When the storage device is overfilled, the card collector stops collecting guest cards and provides four short audio signals at intervals of 4 sec., the LED panel flashes red cross indicator at an interval of 4 seconds.
Check the connection cable; Check the fuses on motherboard the speedgate does not work Check the RC panel connection; RC panel does not work +12 and GND contacts are connected properly try to interchange positions of CL and CH; Praktika T-05(K) speedgate...
Appendix 2. Troubleshooting for card collector LED(r/b) L7113 F3C Optotransistor (y/b) L7113 Fig 6. Location of optocouplers of card collector Operational manual...
Page 20
- If V = 5 V - the phototransistor or cable are defective; 2. IR LED3 (Vtyp = 1,2 B): - If V = 5 V - LED or cable defective; Table 8. Troubleshooting for the card collector Praktika T-05(K) speedgate...
Act in accordance with the article 8.5, "Emergency mode". Card or foreign object is left in card Card collector hole of card provides 5 audio collector signals, red cross on the LED panel Check the voltage at the connectors is blinking (without removing the connectors, (then red cross on while holding down the button...