GE eBike II Series Service Manual page 67

Table of Contents

Advertisement

First the offset value (zero value) is defined („OFFSET").
The displayed strain gauge value should be in the range
between 50 und 220 mV (typical 130 -170 mV).
Press [SET] to store the actual OFFSET.
ATTENTION: The storage of the value needs
some seconds!
Next step is the calibration of the gain factor for the strain
gauge.
2018112-069 Rev. F
Static Load Calib.
OFFSET
DMS-Volt:
S
tatic
Static Load Calib.
DMS-Volt:
S
tatic
Static Load Calibration
GAIN
DMS-Volt:
Max: 1509 ... 1989 mV
Load 8kg weight
S
tatic load calibration
eBike II, eBike II L, eBike II EL
147 mV
Typ: 130 ... 170 mV
Max: 50 ... 250 mV
SET
l
offSet
oad calibration
147 mV
Wait max. 20 sec
l
offSet - S
oad calibration
1676 mV
SET
gain
torage in progreSS
- 67 -