  • Page 1 Instructions Control board for electromechanical gearmotors HERMES...
  • Page 2 89/392 and norm EN 12453 and EN 12445.. • Use only original parts. Stagnoli do not take any responsibility for damage caused by using unoriginal parts. • Before operating the device, make sure that the power supply has been cut off.
  • Page 3 Instructions TECHNICAL SPECIFICATION AND CONNECTION DIAGRAM The electronic control unit for 24V electromechanical gear motors of Stagnoli, is designed for controlling operations of 24 Vdc motors, used for the activation of gates with 1 or 2 shutters; the movement is controlled by the encoder and there is no need to use limit switches.
  • Page 4: Electric Connections

    Instructions ELECTRIC CONNECTIONS 1. Neutral power supply from transformer (20Vac) 2. Phase power supply from transformer (20Vac) 3. Auxiliary output 24Vdc – 500mA (positive pole) 4. Auxiliary output 24Vdc – 500 mA (negative pole ) 5. Connection of grounding 6. Output 1° electric motor 24Vdc (opening) 7.
  • Page 5 Instructions DEFINITIONS OF CONTROL UNIT PARTS F1 – FUSE AUXILIARY OUTPUT ( 0.630A, 250V): protects the center in case of short circuits and faults that may emerge in auxiliary devices. F2- FUSE TRANSFORMER INPUT(10A, 250V): protects the center in case of short circuits or faults that may emerge at the transformer input.
  • Page 6: Functioning Modes

    Instructions FUNCTIONING MODES The unit may control various functions based on the combinations of the Dip Switches: FUNCTION The motors M1 and M2 supply the The motors M1 and M2 SW – 1 ELECTRONIC FRICTION maximum thrust. supply the minimum thrust. The automatic operation is The semi-automatic SW –...
  • Page 7: Receiver (Optional)

    Instructions NOTE 1. In order to secure always the safety of the automation and to enable the proper carrying out of the programming operation, it is necessary to use the mechanical positive stops at the end of the gate’s course ( in opening and in closing). 2.
  • Page 8 Instructions Rev. 0 - 03/06 Stagnoli s.r.l. Via Mantova, Traversa 1^, 105 A/B-25017 Lonato (Bs) - Italia Tel. +39 030 9139511 Fax. +39 030 91380 www.stagnoli.com...