FUSE
The hood control contains a fuse to protect it from power
surges. If the fuse has opened (blown), the green fan-
level indicators will operate properly when the fan
buttons/switches are pressed, but the fan and lights will
not turn on.
The fuse is a 5 x 20mm, 10 Amp, Fast-Acting, 125V
(min.).
FUSE AND SCHEMATIC DIAGRAM
1. Disconnect power at service entrance.
2. Remove filters, bottom panel, light wire harness and air
chute.
3 Remove and inspect fuse. If it is not open (blown), additional
diagnostics need to be done.
4. Install new fuse.
5. Re-assemble air chute, light wire harness, bottom panel and
filters.
6. Turn on power and check hood/control operation.