Æ Downloads including the Installation Guide, Spec Sheet, and Owner’s Manual CONTACT US If at any time you have questions or comments concerning your SHARP product, please contact the SHARP Customer Assistance Center. We are available to assist you through multiple contact methods for your convenience:...
Sharp. The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and exclusive remedy available to the purchaser.
BTU/hr. as the blower motor will shut down intermittently. code authorities. Your hood motor has a thermal overload which will This product may have sharp edges. Be careful to avoid cuts automatically shut off the motor if it becomes overheated. The and abrasions during installation or cleaning.
RANGE HOOD MAIN PARTS PARTS INCLUDED Unpack hood and check contents. You should receive: FOR MODEL: SHC2432FS FOR MODELS: SHC3062FS, SHC3662FS, SHC3042FS QTY. PRODUCT COMPONENTS Hood QTY. PRODUCT COMPONENTS Hood Decorative Flue Assembly Decorative Flue Assembly Damper / Duct Connector...
MEASURE THE INSTALLATION The minimum hood distance above cooktop MUST NOT BE LESS than 26". A maximum of 36" above cooktop is highly recommended for best capture of cooking impurities. Distances over 36" are at the installer and users discretion; providing that the ceiling height permits. SIDE VIEW ROOF CAP 6”...
INSTALLATION INSTRUCTIONS DAMPER/ADAPTER PREPARATION INSTALL THE DUCTWORK (DUCTED FOR SHC2432FS: HOODS ONLY) Damper is packed in side carton separately. Use four Mounting Screws (no. 8 x " Pan Head) to fix the damper as shown in Decide where the ductwork will run between the hood and the picture below.
Page 11
INSTALLATION INSTRUCTIONS To make sure there will be adequate clearance between top INSTALL UPPER FLUE MOUNTING of hood and lower flue mounting bracket for ductwork: Elbow BRACKET must be located below lower flue mounting bracket. If a framing member is not present, drill two "...
Page 12
INSTALLATION INSTRUCTIONS Plug hood power cord into the outlet. INSTALL THE HOOD (VERTICALLY DUCTED HOODS ONLY) DO NOT REMOVE the protective plastic film covering the LOWER FLUE MOUNTING BRACKET decorative flue and the hood at this time. Lay the back side of the hood flat on a table. Use a piece of cardboard to avoid damaging the table or the hood.
Page 13
ASSEMBLY AVAILABLE ACCESSORY PARTS NUMBERS RANGE NON-DUCT CHARCOAL EXTENSION SIDE VIEW HOOD FILTERS FLUE SHC2432FS SKCH32DLK SKCH32CFL SHC3042FS HOLES LOCATION Ø 5/16" TYP. SKCH62EXF SHC3062FS SKCH62DLK SKCH62CFL HD1223 With the hood hanging in place, drill through both holes SHC3662FS located in the inside lower back of hood using a "...
Page 14
For replacement non-duct recirculation filters - purchase SKCH32CFL for SHC2432FS; SKCH62CFL for SHC3062FS, SHC3042FS and SHC3662FS (set of 2 filters). Remove protective plastic film covering the flue and the hood.
OPERATIONS CONTROL PANEL BLOWER LIGHT 15 MINUTE POWER DISPLAY CONTROLS ON/OFF DELAY ON/OFF LED DISPLAY CAP (CFM ADJUSTABLE PLATFORM) SETTING (SHC3062FS & SHC3662FS ONLY) • It indicates the blower power level by number. In case the blower power (CFM = Cubic Feet per Minute) shall be limited due to state or local “Makeup Air”...
CLEANING & MAINTENANCE Proper maintenance of the Range Hood will assure proper STAINLESS STEEL CLEANING performance of the unit. • Regularly wash with clean cloth or rag soaked with warm MOTOR The motor is permanently lubricated and never needs oiling. If water and mild soap or liquid dish detergent.
NOTE Any electrical repairs to this appliance must conform to your local, state and federal laws. Please contact the SHARP Customer Service 1-800-BE-SHARP if there is any questions before undertaking any of the above. Always disconnect the unit from the power...
Page 20
SHARP ELECTRONICS CORPORATION • 100 Paragon Drive • Montvale, New Jersey 07645 • USA...