Your Aquarea unvented cylinder is automatic in normal use, but requires routine
maintenance which is normally carried out at least annually along with the heat pump
service. The maintenance must be carried out by a suitably competent tradesperson
who is qualified to work on unvented cylinders. The checks/work needed are listed
in the maintenance part of these Instructions.
The heat pump control thermostat should turn off the switch live to the three port
valve before the heat pump starts to cycle on its internal thermostats. For example if
the maximum primary flow temperature available from the heat pump is 55°C, then
the control thermostat should be set to 48°C. (This setting should not be changed
by the occupant.)
When initially opening the taps, a small surge in flow may be experienced, which
disappears as the pressure in the system stabilises. This is quite normal with these
types of systems and does not indicate a fault.
In some areas the water will initially appear cloudy, but will quickly clear when left
to stand. This is nothing to be concerned about and is due to aeration of the water.
WARNING - If water is seen flowing through the tundish, this indicates a fault condition
which needs action.
If the discharge is hot and continuous, turn the heat pump and/or the immersion
heaters off, but do not turn off the cold water to the appliance until the discharge
is cold.
Note: The discharge may stop by itself as the discharge cools.
If the discharge is cold and intermittent, no immediate action is needed but this
indicates a problem with the expansion vessel.
However, in both cases you must call the registered installer / a suitably qualified,
competent tradesperson, advise them that you have an unvented cylinder and
request a maintenance visit.
DO NOT, at any time, tamper in any way with the safety valves or overheat thermostats/
wiring.