CONTENT GENIUS LCD 100 The following operating instructions will guide you during commissioning and use of your GENIUS LCD 100 and answer all essential questions. Please read these operating instructions carefully before using your GENIUS LCD 100 verwenden. Included in delivery Safety instructions Preamble Setting menu...
1. INCLUDED IN DELIVERY GENIUS LCD 100 1x GENIUS LCD100 1x Operating manual 3x Adapters (Danfoss RA / RAV / RAVL) 1x Screw for adapter 2x Batteries AA LR6 NOTE! The following figures are for illustration purposes only and may differ from the actual product.
- Operate GENIUS LCD100 only as described in the user manual. - GENIUS LCD100 should only be put to use in a dry and dust-free place, away from direct sunlight. - Do not keep using the device when there is obvious damage.
GENIUS LCD 100 Thank you for purchasing a product from Eurotronic Technology GmbH. This device is designed to adjust the tempera- ture in your rooms comfortably and completely according to your needs while helping you to reduce your heating costs effectively.
4. SETTING MENU GENIUS LCD 100 Press MENU to enter the selection menu. Use the PLUS/MINUS buttons to navigate through the menu. Press OK/SET to select a menu item and PLUS/MINUS to change the values. Press OK/SET to confirm your entry and MENU to return to the previous menu level.
5. OPERATING AND DISPLAY ELEMENTS GENIUS LCD 100 Heating profile active Economy temperature OK/SET = for confirmation PLUS = scroll further/increase temperature MINUS = scroll back/lower temperature MENU = get to the menu Key lock active Battery level display Fast-Link transmission running (animation is displayed) Fast-Link was successful Fast-Link was not successful Window-open-detection active...
6. COMMISSIONING GENIUS LCD 100 6.1 INSERTING/CHANGING BATTERIES 1. Entfernen Sie den Batteriedeckel, indem Sie ihn an der Einkerbung nach oben ziehen (ill. 1). 2. Legen Sie nun die Batterien ein. Achten Sie auf die richtige Polarität! Verwenden Sie keine Akkus! 3.
6.3 MOUNTING ON RADIATOR GENIUS LCD 100 GENIUS LCD 100 can easily be mounted on all known valve bodies (see adapter list at https:/ /eurotronic.org/service/faq). 1. Unscrew the old thermostatic head completely, loosen the fastening and pull it off the valve (ill. 3).
M28 x 1,0 mm, Pettinaroli M28 x 1,5 mm, T+A M28 x 1,5 mm, Gampper 1/2/6; Danfoss RA/RAV/RAVL. For additional adaptors, please visit: http:/ /shop.eurotronic.org If you are not sure which valve you are using, please visit: https:/ /eurotronic.org/Service/FAQ here you will find a list of various valves and adapters.
6.5 ADAPTATION GENIUS LCD 100 After the installation has been completed, GENIUS LCD 100 is able to start adapting by holding down OK/SET for ap- prox. 3 seconds. The device now adapts to the stroke of your valve body. To do this, the valve is now opened and closed several times to learn the respective end points.
Using Fast-Link technology, the settings are then transmitted to the controller simply by holding the smartphone on to it. To use Fast-Link you need the Eurotronic GENIUS App. Download the free „Eurotronic GENIUS“ application from the Apple App Store (iOS) or Google Play Store (Android) to your smartphone or tablet.
8. GENIUS APP GENIUS LCD 100 Back to the home page. Please select your device: GENIUS LCD100. You can skip the quick start guide. By „wiping further“ you can display the assembly instructions in four steps. NOTE: Please remember to transmit the data via Fast-Link as soon as you have made a change in the app.
8.2 TEMPERATURE (APP) GENIUS LCD 100 With the setting wheel you can set your comfort temperature and economy temperature, which will then be used for your heating profiles. The temperature shown above is Determine the temperature with which the heating is to be car- the one currently ried out during the heating times.
8.4 HOLIDAY (APP) GENIUS LCD 100 Select the time of your de- parture. Select the time of your return. Determine the room tempe- rature for the duration of your absence. Select your time and After you have created your confirm with OK. holiday profile, transmit it via Select your month and day and Fast-Link.
9. BASIC OPERATING MODES GENIUS LCD 100 HEATING PROFILE OFF: In manual mode, GENIUS LCD 100 regulates the temperature to the manually set value. In this mode, the timer func- tion is disabled. HEATING PROFILE ON: In automatic mode, GENIUS LCD 100 switches between two temperatures according to the set time programme: Com- fort temperature (factory setting 21°C) and economy temperature (factory setting 16°C).
9. BASIC OPERATING MODES GENIUS LCD 100 HEATING PROFILE: The heating and saving times can be defined by the freely adjustable time programme. GENIUS LCD 100 has the follo- wing factory default setting: Heating time: Heating to comfort temperature (factory setting): 1st heating time at 07:00 am) Saving time: Reduction to economy temperature (factory setting: 1st saving time at 10:00 pm) Create heating plans - define heating and saving times With GENIUS LCD 100 you can set 4 heating and 4 saving times per day - for each day individually or for several days...
10. FURTHER FUNCTIONS GENIUS LCD 100 Align the display: Depending on the position of your radiator valve, it may be necessary to rotate the display of your controller by 180°. To do this, press MENU and select ROTATE LCD to rotate the display accordingly. OK? appears in the display, which can now be rotated and adjusted with PLUS/MINUS.
12. TROUBLESHOOTING GENIUS LCD 100 Problem Cause Solution Batteries almost exhausted. Replace the batteries. Radiator does not warm up. Boiler water temperature OK? Valve Correct boiler water temperature, re- does not open after the summer move GENIUS LCD 100. Move the valve heating break - is it scaled? tappet back and forth several times by hand/tool.
149,7 g (incl. batteries) Degree of protection IP20 Degree of pollution Technical modifications are subject to change. All descriptions for compatibility are without engagement. 14. CONTACT INFORMATION Customer Service: Eurotronic Technology GmbH Südweg 1 36396 Steinau-Ulmbach Germany Telephone: +49 (0) 6667 91847- 0 Email: info@eurotronic.org...
A new or repaired device will then be sent to you free of charge. Please note that Eurotronic only grants warranty on the function of the device. Eurotronic will not grant warranty for the interaction between the thermostat and the bottom part of the valve. The technical data is only valid for the use of the following valves: Heimeier, Junkers Landys + Gyr, MNG, Honeywell, Braukmann (measure of thread M30 x 1,5), Oventrop (M30 x 1,5) Danfoss RA, RAV and RAVL.