To replace the glass on a Raymarine ST40, you can 3D print a new cover using the file available at www.thingiverse.com/thing:4302817. If you don't have a 3D printer, you can send the file to a 3D printing service. Alternatively, you can create a replacement by applying a couple of layers of clear packing tape over the instrument, followed by two layers of epoxy and fiberglass cloth. For a more advanced finish, use a 50/50 mix of carbon fiber and fiberglass tape, then sand and apply a clear finish.
Page 3
Incorporation, use or attachment, by any means, of parts or components not supplied for or not approved for such use by Raymarine or, if supplied or approved for use by Raymarine, not properly fitted in accordance with instructions published, provided or recommended by Raymarine, may cause the equipment to malfunction and, in particular, to become unsafe or to no longer meet the relevant CE requirements.
Page 5
Part 1 Instrument Disassembly & Reassembly Part 1 Instrument Disassembly & Reassembly Contents ST40 instrument spare parts list .............. 1-1 Disassembly ..................... 1-1 Reassembly ....................1-3 ST40 Instruments Service Manual 83149-2...
Page 6
Part 1 Instrument Disassembly & Reassembly ST40 Instrument exploded view ST40 Instruments Service Manual 83149-2...
Not illustrated Disassembly In order to completely disassemble an ST40 instrument, ensure you have a Back Case Removal Tool, Part No. E25031, available from Raymarine. As it is recommended that new inner and outer seals (9a) and (9b) are fitted each time an ST40 instrument is reassembled, ensure that new seals are available, before commencing disassembly.
Page 8
(8) as shown, then gently twist the tool to prise the front fascia from the back cover. Separating front fascia from back cover D5039-1 Repeat this procedure for each edge of the instrument, until the front fascia and the back case are completely separated. ST40 Instruments Service Manual 83149-2...
Page 9
Place the display label (4) in position in the front fascia assembly. CAUTION: Damage to the ST40 instrument can occur if screws are overtightened. Always use the recommended torque values. Fit the PCB/LCD/spade assembly (3) to the front fascia (2) and secure these items together with the two screws and washers (6) and (5).
Page 10
Part 1 Instrument Disassembly & Assembly D5038-1 Gently but firmly press the bezel onto the instrument until it clicks into place. D5038-2 Reassembly is now complete. ST40 Instruments Service Manual 83149-2...
Approximately 1.8 V at 0 degrees C. OVANA Refer also to the ST40 Speed circuit diagram. Self-testing Each ST40 instrument has built-in self-test functions to aid fault diagnosis. To self-test an ST40 Speed instrument: • Press the keys simultaneously for 4 seconds, to access self-test mode,...
LCD segment(s) missing completely Check LCD pins for poor/dry joints. Check IC7 pins for poor/dry joints. Faint LCD segments Check LCD for short circuited pins. Check IC7 for short circuited pins. Check the contrast drive circuit around TR6. ST40 Instruments Service Manual 83149-2...
Chapter 1, ST40 Speed Instrument Press the keys together momentarily, to proceed to self-test stage 3. Self-test stage 3 Note: A known good speed transducer must be connected for this test. When entering self test stage 3, the instrument beeps and the display shows TEST3, for 1 second.
DEPTH_0V Refer also to the ST40 Depth circuit diagram. Self-test procedure Each ST40 instrument has built-in self-test functions to aid fault diagnosis. To self-test an ST40 Depth instrument: • Press the keys simultaneously for 4 seconds, to access self-test mode,...
3. Self-test stage 3 Note: A known good depth transducer should be connected and placed in water, for this test. If this is not possible, an echo simulator can be used. 2-10 ST40 Instruments Service Manual 83149-2...
Page 23
Chapter 2, ST40 Depth Instrument When entering self test stage 3, the instrument beeps and the display shows TEST3, for 1 second. A transducer test then starts. If the interface is working correctly, PASS is displayed. If the test fails, FAIL 43 is displayed. Use the following table to try to isolate the cause.
OVANA Refer also to the ST40 Bidata circuit diagram. Self-test procedure Each ST40 instrument has built-in self-test functions to aid fault diagnosis. To self-test an ST40 Bidata instrument: • Press the keys simultaneously for 4 seconds, to access self-test mode,...
Check LCD pins for poor/dry joints. Check IC7 pins for poor/dry joints. Faint LCD segments Check LCD for short circuited pins. Check IC7 for short circuited pins. Check the contrast drive circuit around TR6. 2-20 ST40 Instruments Service Manual 83149-2...
If the test fails, either a FAIL44 (speed circuit) or FAIL43 (depth circuit) is indicated. Use the appropriate table in either Chapter 1, ST40 Speed Instrument or Chapter 2, ST40 Depth Instrument, to isolate the cause. Press the keys together momentarily to exit self-test.
ROTA- Refer also to the ST40 Wind circuit diagram. Self-test procedure Each ST40 instrument has built-in self-test functions to aid fault diagnosis. To self-test an ST40 Wind instrument: • Press the keys simultaneously for 4 seconds, to access self-test mode,...
Check IC7 pins for poor/dry joints. Faint LCD segments Check LCD for short circuited pins. Check IC7 for short circuited pins. Check the contrast drive circuit around TR6. Press the keys together momentarily, to proceed to self-test stage 3. 2-30 ST40 Instruments Service Manual 83149-2...
Chapter 4, ST40 Wind Instrument Self-test stage 3 Note: A known good Rotavecta transducer must be connected, for this test. When entering self test stage 3, the instrument beeps and the display shows TEST3, for 1 second. A transducer test then starts. Within the next 15 seconds, manually spin the Rotavecta cups, so they rotate at approximately 20 rpm, or faster.
Fluxgate drive Refer also to the ST40 Compass circuit diagram. Self-test procedure Each ST40 instrument has built-in self-test functions to aid fault diagnosis. To self-test an ST40 Compass instrument: • Press the keys simultaneously for 4 seconds, to access self-test mode,...
Check IC7 pins for poor/dry joints. Faint LCD segments Check LCD for short circuited pins. Check IC7 for short circuited pins. Check the contrast drive circuit around TR6. Press the keys together momentarily, to proceed to self-test stage 3. 2-38 ST40 Instruments Service Manual 83149-2...
Chapter 5, ST40 Compass Instrument Self-test stage 3 Note: A known good Fluxgate Compass transducer must be connected, for this test. When entering self test stage 3, the instrument beeps and the display shows TEST3, for 1 second. If the instrument detects valid compass readings in all four heading quadrants within 15 seconds of the start of test stage 3 and if the compass transducer interface is satisfactory, PASS is shown on the display.
ST40 Speed transducer D4518-2 Changing a paddlewheel To change a paddlewheel, refer to the ST40 Speed transducer illustration, and: 1. Use the new paddlewheel shaft from the spare parts kit to push out the old shaft (1) approximately 5 mm (1/4 inch).
Do NOT attempt to remove the self-sealing valve assembly when the vessel is in the water, as the consequent inflow of water may cause the vessel to sink. If the valve mechanism fails, ensure the vessel is not in the water, refer to the ST40 Speed transducer illustration, and carry out the following: 1.
11.2 V dc in amplitude at 5.5 Hz/knot. Screen White TEMP With transducer attached, voltage here is dependent on temperature. Approximately 1.8 V at 0 degrees C. Brown 0VANA ST40 Instruments Service Manual 83149-2 3 - 3...
Page 64
Part 3 Transducer Servicing 3 - 4 ST40 Instruments Service Manual 83149-2...
This can be removed by carrying out the linearisation again. If the displayed deviation is greater than +/– 15 degrees the Fluxgate should be resited. For installation and calibration information, refer to the ST40 Compass Instrument Owner’s Handbook.
Taken from Drawing No: 4233-001 Issue: C Date: 08.11.93 Rotavecta connections Cable core Signal name at Signal name at Description colour Rotavecta PCB Instrument PCB WIND1 ROTA+ Constant current source Blue WIND2 ROTA– ST40 Instruments Service Manual 83149-2 3 - 9...
Page 70
Part 3 Transducer Servicing 3-10 ST40 Instruments Service Manual 83149-2...
Need help?
Do you have a question about the ST40 and is the answer not in the manual?
Questions and answers
Como cambiar el vidrio
To replace the glass on a Raymarine ST40, you can 3D print a new cover using the file available at www.thingiverse.com/thing:4302817. If you don't have a 3D printer, you can send the file to a 3D printing service. Alternatively, you can create a replacement by applying a couple of layers of clear packing tape over the instrument, followed by two layers of epoxy and fiberglass cloth. For a more advanced finish, use a 50/50 mix of carbon fiber and fiberglass tape, then sand and apply a clear finish.