Conversion To Another Type Of Gas; Jet Table; Changing The Jets; Changing The Main Jets - Miele KM 360 Installation Instructions Manual

Table of Contents

Advertisement

Risk of explosion due to an
incorrect conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an approved and registered gas
installer in strict accordance with
current local and national safety and
building regulations. The installer is
responsible for ensuring that the
appliance functions correctly when
installed.

Jet table

The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Burner
Natural gas
Auxiliary
Normal
Fast
Wok burner
1.70/0.70
ULPG
Auxiliary
Normal
Fast
Wok burner
1.00/0.37

Changing the jets

 Disconnect the cooktop from the
electricity supply and turn off the gas
supply.

Conversion to another type of gas

Main jet
Small jet
0.90
0.42
1.10
0.52
1.50
0.60
1.30 (1A)
0.52
0.23
0.70
0.32
0.87
0.40
0.68
When converting to another type of
gas, both the main and small jets
need to be changed.

Changing the main jets

Auxiliary, normal and fast burners
 Remove the pan support, burner
cap  and burner head .
 Using an M7 socket spanner,
unscrew the main jet .
 Fit the correct jets securely (see jet
table).
 Secure the jets against inadvertent
loosening with sealing wax.
21