Appendix Bdip-Switch Information - Emhart Teknologies Tucker TMP Series Programming Manual

Control and power unit
Table of Contents

Advertisement

Appendix B:
DIP-Switch Information.
The DIP-switches are located in the unit interior. Please note
that only electrotechnically trained personnel may open the unit
Warning
ZCPU DIP-Switches
DIP-Switch 2:
System reset, delete RAM-module.
DIP-Switch 7:
Lock single programming.
DIP-Switch 8:
Lock extended programming.
Customer Interfcace DIP-Switches
Due to the differing interface cards along with their software levels the DIP-switch
configuration differs and therefore must be looked up based on these factors.
Some examples:
TSG-emulation (FK-generation in case of error)
TSG-emulation (FK-generation during slide rail control)
Output "I/O-TOL" or "Feedback BU"
No. of heads (IBS for BMW)
Display of I/O`s on the LED`(IBS for BMW)
Feeder DIP-switches:
The DIP-switches in the feeder are configurated differently depending on the
software. Therefore the feeder service manual must be consulted for details.
Some examples:
Key-operated switch removable in position Auto/All
Proximity switch escapement blade active/deactivated
Internal/external slide rail control
With / without protection gas
With / without lift (LM-Box)
Proximity switch escapement chamber active/deactivated
SKK DIP-Switches:
The DIP-switches in the weld head may differ depending on the pcb type and
therefore the corresponding service manual must be consulted for details.
Some examples:
Pcb B 289 (SKK 240 / 310)l
Pcb B 89 (SKK 160)
LM-Head