  • Page 1 — M A N UA L PDP32.0 Profibus DP communication module Universal Motor Controller UMC100.3...
  • Page 2 Universal Motor Controller UTP22-FBP.0 USB to PROFIBUS interface PDR31.0 Active termination unit for PROFIBUS networks — Related documents Technical documentation Document no. UMC100.3 Manual 2CDC135032D0204 Version information This document is valid for: Profibus DP communication module PDP32.0 Order code 1SAJ242000R0001...
  • Page 3: Table Of Contents

    — Table of contents Overview Installation Diagnosis For the PROFIBUS expert Technical data Ordering data...
  • Page 4: Overview

    PROFIBUS, refer to the above-mentioned standard. The PDP32.0 PROFIBUS DP communication module is an optional device for the ABB motor controllers UMC100.3 which enables the connection of the UMC100.3 to a PROFIBUS network. The UMC100.3 with PDP32.0 is considered a slave on the PROFIBUS network.
  • Page 5: Installation

    (SMK3.0). Mounting the PDP32.0 on the UMC100.3 When the module is installed directly on the UMC100.3 the UMC100.3 with PDP32.0 acts like a device with integrated PROFIBUS communication. No additional accessories are needed. Move down PDP32.0 until snapped-in to fix PDP32.0 on UMC100.3...
  • Page 6 For remote mounting of the PDP32.0, the Single Mounting Kit (SMK3.0) must be used. When remote mounted, the PDP32.0 must be separately supplied to keep the PDP32 online, even in the case when the drawer is removed. Ready made cables to connect the SMK3.0 with the drawer are available, but it is also possible to use own cables.
  • Page 7 U N I V E R S A L M O T O R C O N T R O L L E R U M C 1 0 0 . 3 Unmounting PDP32.0/PDR31.0 Follow the procedure for demounting the PDP32.0/PDR31.0 from UMC100.3 or SMK3.0 For demounting slightly rotate...
  • Page 8 PDP32.0 in a bus segment must have termination switched on. In setups where the PDP32.0 is located in a drawer it is necessary to use an active bus termination at the end of the PROFIBUS line. Use PDR31.0 in that case.
  • Page 9 U N I V E R S A L M O T O R C O N T R O L L E R U M C 1 0 0 . 3 PROFIBUS Line in Drawout Systems where PDP32.0 is installed on UMC100.3 The following figure shows a simplified diagram on how to connect the UMC100.3 to a PROFIBUS network not using...
  • Page 10 The following figure is a simplified illustration of how to connect the UMC100.3 to a PROFIBUS network when using a 9-pin Sub-D connector for connecting the PROFIBUS communication interface PDP32.0. The required grounding of the PROFIBUS cable is not shown in this figure.
  • Page 11 U N I V E R S A L M O T O R C O N T R O L L E R U M C 1 0 0 . 3 PROFIBUS Line in Drawout Systems where PDP32.0 is installed in Cable Chamber The following figure shows a simplified diagram on how to connect the UMC100.3 to a PROFIBUS network if the UMC100.3 is...
  • Page 12: Diagnosis

    P D P 3 2 . 0 M A N U A L — Diagnosis Diagnosis and behavior in case of error The PROFIBUS module provides detailed diagnosis information about the status of the connected device, its own status and the status of the PROFIBUS connection.
  • Page 13: For The Profibus Expert

    "Ignore block parameters“ is not set to "Ignore“. Online reconfiguration: PROFIBUS module does not support ‘Hot Configuration In Run’ as supported by some ABB control systems. Whenever a configuration change is done, the module must be restarted to ensure that the configuration gets accepted.
  • Page 14: Technical Data

    — Technical data Data at T = 25 °C and rated values, unless otherwise indicated General data PDP32.0 PDR31.0 Supply voltage 24 V DC + 30% / - 20% (19.2 … 31.2 V DC) Current consumption 55 mA (excl. load on 5 V supply for...
  • Page 15 U N I V E R S A L M O T O R C O N T R O L L E R U M C 1 0 0 . 3 Dimensions 22.5 0.886" 105.2 4.142" SMK3.0 PDP32 / PDR31 Connection Cables Color Function...
  • Page 16 P D P 3 2 . 0 M A N U A L Block diagrams PDP32.0/PDR31.0 24 V DC uC + RS485 <-> UMC ASIC Driver SHLD PDP32 24 V DC R390 R390 R220 SHLD PDR31...
  • Page 17: Ordering Data

    Set of terminals X2 (2 pole), packaging unit 10 pcs 1SAJ929620R0001 SMK3-X1.10 Set of terminals X1 (5 pole), packaging unit 10 pcs 1SAJ929600R0001 SMK3.0 Single Mounting Kit for communication interfaces 1SAJ242000R0001 PDP32.0 Communication module for PROFIBUS DP 1SAJ243000R0001 PDR31.0 Active termination unit for PROFIBUS networks...
  • Page 18 Any reproduction, regard to purchase orders, the agreed disclosure to third parties or utilization of particulars shall prevail. ABB AG does not its contents – in whole or in parts – is accept any responsibility whatsoever for forbidden without prior written consent of potential errors or possible lack of infor- ABB AG.