Summary of Contents for GPS GPS-iMOD

  • Page 1 GLOBAL PLASMA SOLUTIONS ® GPS-iMOD Installation Operation & Maintenance Manual 10 Mall Terrace, Building C Savannah, GA 31406 (912) 356-0115 www.globalplasmasolutions.com 031919-GPSIMOD-IOM REV E.docx...
  • Page 2 4. End cap for each iMOD assembly bar. End cap inserts into the last modular section of the bar to prevent contamination. 5. A minimum of 2 mounting magnets per bar for securing the GPS-iMOD to the cooling coil inlet or filter rack. Magnet quantity provided will increase based on overall bar length.
  • Page 3 Do not hold iMOD between sections while assembling to avoid pinching. Proper Assembly First Modular FIGURE 8 Section Powerhead FIGURE 7 GPS, iMOD, iDetect-P and its logos are trademarks of Global Plasma Solutions, Inc. 031919-GPSIMOD-IOM REV E.docx www.globalplasmasolutions.com ©2019 Global Plasma Solutions, Inc.
  • Page 4 NOTE: The installing contractor will have to provide a piece of metal angle across the face of the coil to attach the GPS-iMOD if the coil finned surface area is over 3 feet wide.
  • Page 5 TO BE IN THE CORRECT POSITION FOR THE PRIMARY POWER BEING APPLIED (See FIGURE 15). The GPS-iMOD system requires a total of 15 watts to power up to 6 GPS-iMODs at any length. The power supply will accept 24VAC, 115VAC or 208- 240VAC at 50HZ or 60HZ.
  • Page 6 CONNECTION TO BMS/BAS The GPS-iMOD has an internal ionization output sensing circuit. The external GPS-iDETECT-P™ is not required but may be installed as an option. Integral alarm “dry” contacts will close when the system is on and operating properly. To tie into the BMS/BAS for remote monitoring, use 18/2 twisted pair, SHIELDED, plenum rated cable and connect to the BMS/BAS ALARM contact terminals.
  • Page 7: Troubleshooting

    1. Once the voltage selector switch has been set, all HV wire(s) connected and iMODs mounted, turn the power switch to the “ON” position. When the switch is turned “ON” the “Power ON” light will illuminate, letting the user know power is supplied and the GPS-iMOD system is energized.
  • Page 8 GLOBAL PLASMA SOLUTIONS, INC. GPS, iMOD, iDetect-P and its logos are trademarks of Global Plasma Solutions, Inc. 031919-GPSIMOD-IOM REV E.docx www.globalplasmasolutions.com ©2019 Global Plasma Solutions, Inc.