Page 1
Premium Drinking Water System ™ RainSoft Hydrefiner II-SC-BNFP, Hydrefiner II-SC-BNFV ,Hydrefiner II-SC-CHFP and Hydrefiner II-SC-CHFV are tested and certified by WQA to NSF/ANSI 42 and 53 for the specific performance claims as verified and substantiated by test data. See the performance data sheet for specific reduction claims.
Congratulations on your purchase of one of the finest Drinking Water Systems available to homeowners. This Owner’s Manual is designed to assist with the installation, operation, and maintenance of the Hydrefiner II System. It is our sincere hope that this manual is clear, concise, and helpful to you as a new owner.
Shut Off Valve A shut off valve should be used to stop the flow of water to the Hydrefiner II during maintenance and extended periods of inactivity. Additional Specifications Do not install this system where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Parts not included in Package: Inlet shut off valve, 3/8 inch O.D. Tubing, and Mounting Screws. Installation Location For your convenience, the Hydrefiner II filter bracket assembly is designed to be mounted on either side of the cabinet. Installation Instructions 1.
Page 5
3. Mount the System • Use screws (Not Supplied) to secure the Hydrefiner II bracket assembly to the planned location. (See Figure 4) Figure 4 USING PHILPS OFFSET SCREWDRIVER TO SECURE THE FILTER 10.2 in (25.9 cm) TO WALL 10.4 in (26.4 cm) With Cover 5.0 in (12.7 cm)
• Open the new faucet and allow the water to flow for 10 minutes. This process will flush the disinfectant and carbon fines from the system. 4. Cover Assembly • Place Cover onto Hydrefiner II and ensure tubing is correctly secure. (See Figure 7) Figure 7...
4. Replace the filters and reassemble (See helpful tips). system! “Made-to-fit” alternative filters will increase the probability of leaks, putting your 5. Turn on the inlet water to the Hydrefiner II system. entire system at risk! Also, many aftermarket replacement filters are not tested for safe 6.
Faucet Assembly and Info Hole Dimension with use of air gap Ø " Ø 1 " Air Gap OUT " Tube to Drain Connection Air Gap IN Product Water " Tube to UF II IN with " Tube Drain Connection Item # Part No.
Blockage could be internal to the Hydrefiner II or external with the water line. Contact your Rainsoft Dealer for issues wth the Hydrefiner II. 3. Sediment cartridge is Fouled. 3. Replace Sediment Cartridge - Contact your Rainsoft Dealer for New Filters 4.
For as long as you own the equipment RainSoft Division of Aquion, Inc. , believing its HYDREFINER II to be of exceptional quality, hereby warrants said equipment to its first purchaser at retail as follows: THE FILTER HOUSING IS WARRANTED AGAINST DEFECTS IN MANUFACTURE FOR THE LIFETIME OF THE FIRST PURCHASER AT RETAIL.
ACTIVATED CARBON WATER FILTER SYSTEM PERFORMANCE DATA SHEET - page 1 of 2 RainSoft HYDREFINER II- SC models DRINKING WATER FILTRATION SYSTEM • REPLACEMENT FILTERS CAPACITY: 400 GALLONS (1514 LITERS) • FLOW RATE: .5 GPM (1.89 LPM) DESCRIPTION PART NUMBER •...
Page 15
ACTIVATED CARBON WATER FILTER SYSTEM PERFORMANCE DATA SHEET - page 2 of 2 RainSoft HYDREFINER II-SC models DRINKING WATER FILTRATION SYSTEM ADDITIONAL NOTES: • The list of substances which this treatment device reduces does not THIS SYSTEM CONTAINS REPLACEMENT COMPONENTS CRIT- necessarily mean that these substances are present in your water supply.