Lubricating the Machine

Greasing the Fan Shaft Bearings
Service Interval: Before each use or daily
1.
Remove the drive shield from over the pulley
assemblies
(Figure
2.
Grease the fittings on the fan shaft bearings as
illustrated in
Figure 10
grease.
Greasing the Drive Shaft
Service Interval: Every 100 hours
Grease the 2 drive shaft fittings as illustrated in
10
with No. 2 lithium-based grease.
Figure 10
12).
with No. 2 lithium-based
Figure 9

Hydraulic System Safety

Seek immediate medical attention if fluid is injected
into skin. Injected fluid must be surgically removed
within a few hours by a doctor.
Ensure that all hydraulic-fluid hoses and lines are
in good condition and all hydraulic connections
and fittings are tight before applying pressure to
the hydraulic system.
Keep your body and hands away from pinhole
leaks or nozzles that eject high-pressure hydraulic
fluid.
Use cardboard or paper to find hydraulic leaks.
Before disconnecting or performing any work on
the hydraulic system, lower the implement to
the ground and shut off the engine to relieve all
pressure in the system.
To ensure safe, optimal performance of the
machine, use only genuine Toro replacement
parts. Replacement parts made by other
manufacturers could be dangerous, and such use
could void the product warranty.