Parameter Lists
8-32
FC Port Baud Rate
8-33
Parity / Stop Bits
8-34
Estimated cycle time
8-35
Minimum Response Delay
8-36
Max Response Delay
8-37
Max Inter-Char Delay
8-4* FC MC protocol set
8-40
Telegram Selection
8-41
Parameters for Signals
8-42
PCD Write Configuration
8-43
PCD Read Configuration
8-45
BTM Transaction Command
8-46
BTM Transaction Status
8-47
BTM Timeout
8-48
BTM Maximum Errors
8-49
BTM Error Log
8-5* Digital/Bus
8-50
Coasting Select
8-51
Quick Stop Select
8-52
DC Brake Select
8-53
Start Select
8-54
Reversing Select
8-55
Set-up Select
8-56
Preset Reference Select
8-57
Profidrive OFF2 Select
8-58
Profidrive OFF3 Select
8-8* FC Port Diagnostics
8-80
Bus Message Count
8-81
Bus Error Count
8-82
Slave Messages Rcvd
8-83
Slave Error Count
8-9* Bus Jog
8-90
Bus Jog 1 Speed
8-91
Bus Jog 2 Speed
5.2.10 9-** PROFIdrive
Par.
Parameter description
No. #
9-00
Setpoint
9-07
Actual Value
9-15
PCD Write Configuration
9-16
PCD Read Configuration
9-18
Node Address
9-19
Drive Unit System Number
9-22
Telegram Selection
9-23
Parameters for Signals
9-27
Parameter Edit
9-28
Process Control
9-44
Fault Message Counter
9-45
Fault Code
9-47
Fault Number
9-52
Fault Situation Counter
9-53
Profibus Warning Word
9-63
Actual Baud Rate
MG33MP02
Programming Guide
ExpressionLimit
1 set-up
[0] Even Parity, 1 Stop Bit
1 set-up
0 ms
2 set-ups
10 ms
1 set-up
ExpressionLimit
1 set-up
ExpressionLimit
1 set-up
[1] Standard telegram 1
2 set-ups
0
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
[0] Off
All set-ups
[0] Off
All set-ups
60 s
1 set-up
21 N/A
1 set-up
0.255 N/A
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
ExpressionLimit
All set-ups
[3] Logic OR
All set-ups
ExpressionLimit
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
Default value
4-set-up
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
1 set-up
ExpressionLimit
2 set-ups
126 N/A
1 set-up
1034 N/A
All set-ups
[100] None
1 set-up
0
All set-ups
[1] Enabled
2 set-ups
[1] Enable cyclic master
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[255] No baudrate found
All set-ups
Danfoss A/S © 10/2018 All rights reserved.
TRUE
-
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-5
TRUE
-
FALSE
-
TRUE
0
TRUE
0
FALSE
-
TRUE
-
FALSE
0
TRUE
0
TRUE
-3
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
67
TRUE
67
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
0
FALSE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
-
FALSE
-
FALSE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
Uint8
Uint8
Uint32
Uint16
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
Uint8
5
5
Uint8
Uint16
Uint8
Uint32
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
Uint32
Uint32
Uint32
Uint16
Uint16
Type
Uint16
Uint16
Uint16
Uint16
Uint8
Uint16
Uint8
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
Uint16
V2
Uint8
273