Hewlett Packard Enterprise Integrity NonStop X NS7 Planning Manual

Hewlett Packard Enterprise Integrity NonStop X NS7 Planning Manual

Table of Contents

Advertisement

Quick Links

HPE Integrity NonStop X NS7 Planning
Guide
Part Number: 799257-005
Published: September 2018
Edition: L15.08 and subsequent L-series RVUs

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Integrity NonStop X NS7 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hewlett Packard Enterprise Integrity NonStop X NS7

  • Page 1 HPE Integrity NonStop X NS7 Planning Guide Part Number: 799257-005 Published: September 2018 Edition: L15.08 and subsequent L-series RVUs...
  • Page 2: Table Of Contents

    Contents About This Document................7 Supported Release Version Updates (RVUs)................7 New and Changed Information in 799257–005................7 HPE Integrity NonStop X NS7 Systems..........8 Core Licensing..........................11 NonStop X NS7 Standard and Optional Hardware..............12 c7000 Enclosure......................12 NonStop X NS7 Server Blades..................13 CLuster I/O Modules (CLIMs)...................13...
  • Page 3 Planning Kernel Managed Swap (KMS) Space................68 Default Naming Conventions for NS7 Systems................68 Possible values of disk and tape LUNs for NS7 Systems............69 HPE Integrity NonStop X NS7 CG Systems........70 NEBS Required Statements....................... 72 NS7 CG Standard and Optional Hardware................. 73 c7000 CG Enclosure......................
  • Page 4 Site Power Cables for NS7 CG Systems..................92 Required Documentation....................92 Requirements for Site Power or Ground Cables..............92 Websites....................94 Support and other resources...............95 Accessing Hewlett Packard Enterprise Support................. 95 Accessing updates........................95 Customer self repair........................96 Remote support.......................... 96 Warranty information........................96 Regulatory information........................97...
  • Page 5 Ukraine RoHS material content declaration................131...
  • Page 6 Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 7: About This Document

    About This Document This guide provides an overview of HPE Integrity NonStop X NS7 systems, specifications for planning system installation, and is intended for personnel who have completed Hewlett Packard Enterprise training on NonStop X system support. Supported Release Version Updates (RVUs) This publication supports L15.08 and all subsequent L-series RVUs until otherwise indicated in a...
  • Page 8: Hpe Integrity Nonstop X Ns7 Systems

    HPE Integrity NonStop X NS7 Systems ® ® The HPE Integrity NonStop X NS7 system family introduces Intel Xeon x86 technology to NonStop by using a new high bandwidth, low latency InfiniBand system interconnect that is fully-integrated with the fault-tolerant HPE NonStop Operating system.
  • Page 9 The following illustration shows two example configurations for AC power NS7 systems. Figure 1: Example NS7 System Configurations (42U and 36U) HPE Integrity NonStop X NS7 Systems...
  • Page 10 HPE XP 7 Storage Array and HPE XP P9500 Storage Array Storage CLIMs Maintenance LAN Redundant configuration only Minimum NonStop System Consoles for fault-tolerance Connection to NonStop X Supported. For more information, see the NonStop X Cluster Solution Cluster Solution Manual HPE Integrity NonStop X NS7 Systems...
  • Page 11: Core Licensing

    L15.02 and later. NS7 systems support 2-, 4-, and 6-core license options. Anytime you upgrade the level of cores, expand your system by adding server blades, or migrate the system, you must update your license file. Your service provider is responsible for obtaining and installing HPE Integrity NonStop X NS7 Systems...
  • Page 12: Nonstop X Ns7 Standard And Optional Hardware

    • Two Onboard Administrator (OA) modules manage and monitor the Intelligent Infrastructure and let you monitor and control resources using the HPE Insight Display as described in the HPE BladeSystem Onboard Administrator User Guide. HPE Integrity NonStop X NS7 Systems...
  • Page 13: Nonstop X Ns7 Server Blades

    To identify a CLIM, see the number on the rear label; this number is listed as the part number in OSM. NS7 system Ships with NS7 X3 Gen10 CLIMs NS7 X2 Gen9 CLIMs NS7 X1 Gen8 CLIMs HPE Integrity NonStop X NS7 Systems...
  • Page 14 10GbE 2-port adapter copper NIC for Eth3 and Eth4 customer interfaces. LAN1 - LAN4 • LAN1 is reserved for Maintenance LAN interface for maintenance support. • LAN2 provides 1GbE port for Eth5 interface. • LAN3 and LAN4 are not used. Maintenance LAN interface. HPE Integrity NonStop X NS7 Systems...
  • Page 15 10GbE 2-port adapter for Eth3 and Eth4 customer interfaces. LAN1 - LAN4 • LAN1 is reserved for Maintenance LAN interface for maintenance support. • LAN2 provides 1GbE port for Eth5 interface. • LAN3 and LAN4 are not used. Maintenance LAN interface. HPE Integrity NonStop X NS7 Systems...
  • Page 16 10GbE 2-port adapter copper NIC for Eth3 and Eth4 customer interfaces. LAN1 - LAN4 • LAN1 is reserved for Maintenance LAN interface for maintenance support. • LAN2 provides 1GbE port for Eth5 interface. • LAN3 and LAN4 are not used. Maintenance LAN interface. HPE Integrity NonStop X NS7 Systems...
  • Page 17 10GbE 2-port adapter for Eth3 and Eth4 customer interfaces. LAN1 - LAN4 • LAN1 is reserved for Maintenance LAN interface for maintenance support. • LAN2 provides 1GbE port for Eth5 interface. • LAN3 and LAN4 are not used. Maintenance LAN interface. HPE Integrity NonStop X NS7 Systems...
  • Page 18 1GbE 2-port adapter for Eth5 customer port and Eth0 for maintenance support. FlexLOM 10GbE 2-port adapter for Eth2 and Eth1 customer ports IP or Telco CLIM Option 2 — Four 10GBase-SR and One 1GBase-T HPE Integrity NonStop X NS7 Systems...
  • Page 19 ESS and FC tape devices using 3 PCIe HBA slots. Item Characteristics of Gen10 Storage CLIM Slot 1 InfiniBand interface card provides InfiniBand X-fabric and Y-fabric connections. Slot 2 SAS HBA with two 12G SAS ports: 1E, 2E. Table Continued HPE Integrity NonStop X NS7 Systems...
  • Page 20 Provides maintenance services and connects to Maintenance LAN. LAN1 - LAN4 • LAN1 is reserved for Maintenance LAN interface for maintenance support. • LAN2 provides 1GbE port for Eth1 interface to support ESKM (optional). • LAN3 and LAN4 are not used. HPE Integrity NonStop X NS7 Systems...
  • Page 21 25 2.5” SAS Smart Carrier HDDs and SSDs with redundant power and cooling as described in the HPE D3600/D3700 Disk Enclosure User Guide. The following illustration shows the front and rear panel of the D3700 SAS Disk Enclosure. HPE Integrity NonStop X NS7 Systems...
  • Page 22: Nonstop Io Expansion Ib Switch

    CLIM I/O connections. For information on connecting the switch, refer your service provider to the Technical Document for NS7 Systems on page 26 and the CLuster I/O (CLIM) Installation and Configuration Guide (L15.02+). HPE Integrity NonStop X NS7 Systems...
  • Page 23: Nonstop X Fdr Ib Adi Switch

    OSM console tools. To manage the system, an NS7 requires two system consoles running Windows Server 2008, 2012, or 2016. New system consoles arrive preconfigured with all required HPE and third-party console software. HPE Integrity NonStop X NS7 Systems...
  • Page 24: Ups And Erm (Optional)

    NOTE: Procedures related to creating or modifying the dedicated service LAN and the system console configurations on that LAN, must be performed by an authorized Hewlett Packard Enterprise service provider as described in the Nonstop Dedicated Service LAN Installation and Configuration Guide for NonStop X systems.
  • Page 25: System Management Tools

    NOTE: The Fibre Channel Storage Area Network (SAN) switch power cords might not be compatible with the rack PDU. Contact your Hewlett Packard Enterprise service provider to order replacement power cords, if needed. Connection Interfaces, Ports, and Cables Fibre Channel Switches...
  • Page 26: Management Subsystems For Ns7 Systems

    U, with one U measuring 1.75 inches (44 millimeters). The rack is 36U with U1 located at the bottom and 36U at the top or 42U with U1 located at the bottom and 42U at the top. The rack offset is the lowest number on the rack that the component occupies. HPE Integrity NonStop X NS7 Systems...
  • Page 27: Site Preparation Guidelines For The Ns7 System

    This chapter provides guidelines for preparing a site for an NS7 system. Rack Power and I/O Cable Entry Depending on how the racks are ordered from Hewlett Packard Enterprise and the routing of the AC power feeds at the site, AC power cords for the PDUs exit either: •...
  • Page 28: Electrical Power And Grounding Quality

    For an airflow assessment, consult with your Hewlett Packard Enterprise cooling consultant or your heating, ventilation, and air conditioning (HVAC) engineer.
  • Page 29: Weight

    NS7 Rack and Enclosure Weights With Worksheet on page 58. For your site’s floor system, consult with your Hewlett Packard Enterprise site preparation specialist or an appropriate floor system engineer. If raised flooring is to be used, the rack is optimized for placement on 24‑inch floor panels.
  • Page 30: Operational Space For An Ns7 System

    √ Verify Tiled or carpeted pathways have temporary hard floor covering to facilitate moving the racks which have small casters. Door and hallway width and height, the floor and elevator loading, accommodate the system equipment, personnel, and lifting or moving devices. If necessary, enlarge or remove any obstructing doorway or wall.
  • Page 31: Ns7 System Installation Specifications

    NS7 System Installation Specifications This chapter provides specifications necessary for system installation planning. All specifications in this chapter assume that each enclosure in the rack is fully populated. The maximum current for each AC service depends on the number and type of enclosures installed in the rack. Power, weight, and heat loads are less when enclosures are not fully populated;...
  • Page 32 ◦ The breakers face outward. ◦ The output receptacles face inward. • Rear-mounted PDU cores connect to the extension bars on the right side of the rack. • Front-mounted PDU cores connect to the extension bars on the left side of the rack and to an UPS (if present).
  • Page 33: Pdu Supported Pdu Types Configurations

    Supported PDU Examples of Configurations Types Configurations Four PDU cores with UPS Four Modular G2 Basic PDUs in an Advanced Series G2 rack with single-phase UPS (NA/JPN and INTL) on page 41 Four Modular G2 Basic PDUs in an Advanced Series rack with Three-Phase UPS (NA/JPN and INTL) on page 42 Two PDU cores without UPS...
  • Page 34: Four Intelligent Pdus In An Advanced Series G2 Rack

    Figure 2: Four iPDUs Without UPS — (NA/JPN and INTL, Single-Phase and Three-Phase) Four Intelligent PDUs in an Advanced Series G2 rack with single-phase UPS – (NA/JPN and INTL) This illustration shows the power configuration for 4 iPDUs and 2 single-phase UPS's in an Advanced Series G2 rack.
  • Page 35: Four Intelligent Pdus In An Advanced Series G2 Rack With Three-Phase Ups (Na/Jpn And Intl)

    Figure 3: Four iPDUs With Single-Phase UPS — (NA/JPN and INTL) Four Intelligent PDUs in an Advanced Series G2 rack with three-phase UPS (NA/JPN and INTL) This illustration shows the power configuration for 4 iPDUs and 2 single-phase UPS's in an Advanced Series G2 rack.
  • Page 36: Two Intelligent Pdus In An Advanced Series G2 Rack Without Ups - (Na/Jpn And Intl)

    Figure 4: Four iPDUs With Three-Phase UPS — (NA/JPN and INTL) Two Intelligent PDUs in an Advanced Series G2 rack without UPS — (NA/JPN and INTL) This illustration shows the connections for two iPDUs in an Advanced Series G2 rack without a UPS. For detailed power specifications and connector types, see AC input power for an Advanced Series G2 rack.
  • Page 37: Two Intelligent Pdus In An Advanced Series G2 Rack

    Figure 5: Two Intelligent PDUs Without UPS— (NA/JPN and INTL, Single-Phase and Three-Phase) Two Intelligent PDUs in an Advanced Series G2 rack with single-phase UPS — (NA/JPN and INTL) This illustration shows the power configuration for 2 iPDUs and a single-phase UPS in an Advanced Series G2 rack.
  • Page 38 Figure 6: Two Intelligent PDUs With Single-Phase — (NA/JPN and INTL) Two Intelligent PDUs in an Advanced Series G2 rack with three-phase UPS — (NA/JPN and INTL) This illustration shows the power configuration for 2 iPDUs and a three-phase UPS in an Advanced Series G2 rack.
  • Page 39: Four G2 Basic Modular Pdus In An Advanced Series Rack Without Ups - (Na/Jpn And Intl)

    Figure 7: Two Intelligent PDUs With Three-Phase UPS — (NA/JPN and INTL) Four G2 Basic Modular PDUs in an Advanced Series rack without UPS — (NA/JPN and INTL) This illustration shows the power configuration for four single-phase modular PDUs in an Advanced Series G2 rack without a UPS.
  • Page 40 Figure 8: Four G2 Basic Modular PDUs without UPS — (NA/JPN and INTL, Single-Phase) This illustration shows the power configuration for four three-phase modular PDUs in an Advanced Series G2 rack without a UPS. For detailed power specifications and connector types, see AC input power for a NonStop System in an Advanced Series G2 rack.
  • Page 41: Four Modular G2 Basic Pdus In An Advanced Series G2 Rack With Single-Phase Ups (Na/Jpn And Intl)

    Figure 9: Four G2 Basic Modular PDUs without UPS — (NA/JPN and INTL, Three-Phase) Four Modular G2 Basic PDUs in an Advanced Series G2 rack with single-phase UPS (NA/JPN and INTL) This illustration shows the power configuration for 4 modular G2 Basic PDUs and 2 single-phase UPS's in an Advanced Series G2 rack.
  • Page 42: Four Modular G2 Basic Pdus In An Advanced Series Rack With Three-Phase Ups (Na/Jpn And Intl)

    Figure 10: Four Modular G2 Basic PDUs with single-phase UPS — (NA/JPN and INTL) Four Modular G2 Basic PDUs in an Advanced Series rack with Three-Phase UPS (NA/JPN and INTL) This illustration shows the power configuration for 4 modular G2 Basic PDUs and one three-phase UPS in an Advanced Series G2 rack.
  • Page 43: Two Modular G2 Basic Pdus In An Advanced Series Rack With Three-Phase Ups - (Na/Jpn And Intl)

    Figure 11: Four Modular G2 Basic PDUs with three-phase UPS — (NA/JPN and INTL) Two Modular G2 Basic PDUs in an Advanced Series rack with three-phase UPS — (NA/JPN and INTL) This illustration shows the connections for 2 modular G2 Basic PDUs in an Advanced Series G2 rack with a three-phase UPS and without a c7000 enclosure.
  • Page 44: Two Modular G2 Basic Pdus In An Advanced Series Rack With Single-Phase Ups - (Na/Jpn And Intl)

    Figure 12: Two Modular G2 Basic PDUs with a three-phase UPS — (NA/JPN and INTL) Two Modular G2 Basic PDUs in an Advanced Series rack with single-phase UPS — (NA/JPN and INTL) This illustration shows the connections for 2 modular G2 Basic PDUs in an Advanced Series G2 rack with a single-phase UPS and without a c7000 enclosure.
  • Page 45: Two G2 Basic Modular Pdus In An Advanced Series G2 Rack Without A C7000 Enclosure Or Ups - (Na/Jpn And Intl)

    Two G2 Basic Modular PDUs in an Advanced Series G2 rack without a c7000 enclosure or UPS — (NA/JPN and INTL) This illustration shows the power configuration for 2 modular G2 Basic PDUs in an Advanced Series rack without a c7000 enclosure or UPS. For detailed power specifications and connector types, see AC input power for an Advanced Series G2 rack.
  • Page 46 NS7 System Installation Specifications...
  • Page 47: Ac Input Power For An Advanced Series G2 Rack

    AC input power for an Advanced Series G2 rack The following tables provide the power specifications for AC input power in an Advanced Series G2 rack. CAUTION: Be sure the hardware configuration and resultant power loads of each enclosure within the system do not exceed the capacity of the branch circuit according to applicable electrical codes and regulations.
  • Page 48 Table 4: North America/Japan single-phase power specifications R5000 single-phase iPDU single-phase G2 Basic Modular single-phase Output Load 4500 W 24 A 24 A Input Voltage 200 – 208 V 200 – 208 V 200 – 240 V Input Connector NEMA L6-30P NEMA L6-30P NEMA L6-30P Output Voltage...
  • Page 49 Table 6: International single-phase power specifications R5000 single-phase iPDU single-phase G2 Basic Modular single-phase Output Load 4500 W 32 A 32 A Input Voltage 220 – 240 V 200 – 240 V 200 – 240 V Input Connector IEC309 332P6 IEC309 332P6 IEC309 332P6 (32 A)
  • Page 50: Enclosure Ac Input For Nonstop X Systems

    R12000 three-phase iPDU three-phase G2 Basic Modular 3- phase Output Connectors 2 x IEC309 309 516C6 6 x C19 (20 A) 6 x C19 (20 A) Notes UPS outputs are connected to the compatible PDU inputs. Enclosure AC Input for NonStop X Systems Enclosures (IP CLIM, SAS disk enclosure, and so forth) require: Specification Value...
  • Page 51 Enclosure Type AC Power Lines per Typical Power Maximum Power Enclosure Consumption (VA) Consumption (VA) Products used by NS7 X1 AC systems BL460c Gen8 CPU (64 GB RAM) BL460c Gen8 CPU (128 GB RAM) BL460c Gen8 CPU (192 GB RAM) Products used by NS7 X2 AC systems BL460c Gen9 CPU...
  • Page 52 Enclosure Type AC Power Lines per Typical Power Maximum Power Enclosure Consumption (VA) Consumption (VA) 400GB SSD, 12G SAS, SFF, SC 300GB, 15k rpm HDD, 12G SAS, SFF, SC Rack-mounted system console (NSCR216) Rack-mounted keyboard and monitor Deskside system console Deskside system console monitor Common products used...
  • Page 53: Dimensions And Weights For Ns7 Ac Systems

    Enclosure Type AC Power Lines per Typical Power Maximum Power Enclosure Consumption (VA) Consumption (VA) Gen9 Networking CLIM, 4C/1C (IP or Telco) Gen9 Networking CLIM, 3C/2F (IP or Telco) 32GB Memory kit D3700 SAS disk enclosure, empty 400GB SSD, 12G SAS, SFF, SC 300GB, 15k rpm HDD, 12G SAS, SFF, SC...
  • Page 54: Unit Sizes For Ns7 Systems

    Unit Sizes for NS7 Systems Enclosure Type Height (U) Rack 42 or 36 c7000 enclosure CLIMs SAS disk enclosures CLIM patch panel (RJ45 and Fiber) FDR IB ADI switch FDR IB managed switch, expansion IB FDR managed switch, IB cluster Maintenance switch (Ethernet) R5000 UPS (single-phase power) ERM for single-phase UPS...
  • Page 55: 42U Intelligent Rack Physical Specifications

    42U Intelligent Rack physical specifications Item Height Width Depth Weight Rack 78.7 199.9 23.3 59.0 47.6 Depends on the enclosures Shipping 85.8 35.4 57.8 installed. (palletized) See NS7 Rack and Enclosure Weights With Worksheet on page 36U G2 Advanced Series Rack physical specifications Item Height Width...
  • Page 56: 36U Intelligent Rack Physical Specifications

    36U Intelligent Rack physical specifications Item Height Width Depth Weight Rack 68.2 173.1 23.3 59.06 47.6 Depends on the enclosures Shipping 85.8 35.4 57.8 installed. (palletized) See NS7 Rack and Enclosure Weights With Worksheet on page NS7 Enclosure Dimensions Enclosure Height Width Depth...
  • Page 57 Enclosure Height Width Depth Type G2 Basic 17.5 44.5 19.8 Modular PDU (in Advanced Series G2 rack) Modular PDU 17.5 44.5 14.2 (in Intelligent rack) Intelligent 17.5 44.5 19.1 PDU (in Intelligent rack or Advanced Series G2 rack) FDR IB 16.8 42.7 24.7...
  • Page 58: Ns7 Rack And Enclosure Weights With Worksheet

    NS7 Rack and Enclosure Weights With Worksheet The total weight of each rack is the sum the weights of the rack plus each enclosure installed in it. Use this worksheet to determine the total weight: Enclosure Number of Weight Total Type Enclosures 36U rack...
  • Page 59 Enclosure Number of Weight Total Type Enclosures BL460c Gen10 (256GB RAM) Storage/ Networking: Gen8 CLIM Gen9 CLIM Gen10 CLIM 3700/3710 SAS disk enclosure, empty 400GB SSD, 12G SAS, SFF, 2.5in SC 300GB, 15k rpm HDD, 12G SAS, SFF, 2.5 in SC Disk blank CLIM patch panels...
  • Page 60: G2 Basic Modular

    Enclosure Number of Weight Total Type Enclosures Keyboard and display for console Power Distribution: G2 Basic Modular PDU in Advanced Series G2 rack G2 Basic Modular extension bar in Advanced Series G2 rack Intelligent PDU core (in Note: One Intelligent rack iPDU core or Advanced weights 20 lbs.
  • Page 61: Rack Stability For Ns7 Systems

    Enclosure Number of Weight Total Type Enclosures Legacy Modular PDU Note: One core (in legacy modular Intelligent rack) PDU core weighs 12 pounds. A 4 PDU core configuration in an Intelligent rack would weigh 60 lbs (48 lbs for the PDU cores + 12 lbs for extension bars).
  • Page 62: Environmental Specifications For Ns7 Ac Systems

    Rack stability is of special concern when equipment is routinely installed, removed, or accessed within the rack. Stability is addressed through the use of leveling feet, baying kits, fixed stabilizers, and/or ballast. Use baying kits to bay racks to racks of the same height. In all cases, a rack cannot be bayed with another rack of a different height.
  • Page 63 Enclosure type or Number Installed Unit Heat (BTU/ Unit Heat (BTU/ Total (BTU/hour) component hour, Typical Heat hour, Maximum Dissipation) Heat Dissipation) BL460c Gen10 1133 server blade, 64GB BL460c Gen10 3340 server blade, 128GB BL460c Gen10 1054 3596 server blade, 256GB BL460c Gen10 server blade, 64GB...
  • Page 64 Enclosure type or Number Installed Unit Heat (BTU/ Unit Heat (BTU/ Total (BTU/hour) component hour, Typical Heat hour, Maximum Dissipation) Heat Dissipation) Gen10 10GbE Networking CLIM 4C/1C Gen10 10GbE Networking CLIM 4F/1C 3700/3710 SAS disk enclosure, empty SAS HDD, 2.5 inches, 15k rpm SAS, SSD, 2.5in, SC, 15k rpm...
  • Page 65: Operating Temperature, Humidity, And Altitude Specifications For Ns7 Systems

    Operating Temperature, Humidity, and Altitude Specifications for NS7 Systems Specification Operating Range Recommended Range Maximum Rate of Change per Hour Temperature (rack- 41° to 95° F (5° to 35° 68° to 72° F 9° F (5° C) Repetitive mounted system (20°...
  • Page 66: Tested Electrostatic Immunity For Ns7 Systems

    Tested Electrostatic Immunity for NS7 Systems • Contact discharge: 8 KV • Air discharge: 20 KV Nonoperating Temperature, Humidity, and Altitude Specifications for NS7 Systems • Temperature: ◦ Up to 72-hour storage: - 40° to 151° F (-40° to 66° C) ◦...
  • Page 67 Maintenance switch CLIM patch panel Rack (single- 153 - phase) Total 356 2664 3514 9088 11998 For a total thermal load for a system with multiple racks, add the heat outputs for all the racks in the system. NS7 System Installation Specifications...
  • Page 68: Managing Ns7 System Resources

    Managing NS7 System Resources This chapter provides guidelines for managing the system resources. Planning Kernel Managed Swap (KMS) Space HPE uses Kernel Managed Swap (KMS) space to manage virtual memory via swap files controlled by the HPE NonStop operating system. Each CPU has at least one KMS file that provides the swap space needed by processes.
  • Page 69: Possible Values Of Disk And Tape Luns For Ns7 Systems

    Type of Object Naming Convention Example Maintenance CIPSAM $ZTCPnumber $ZTCP0 process Maintenance provider ZTCPnumber ZTCP0 Maintenance CIPSAM $ZTCPnumber $ZTCP1 process Maintenance provider ZTCPnumber ZTCP1 $ZTC0 IPDATA CIPSAM process $ZTCnumber IPDATA provider $ZTC number ZTC0 Maintenance Telserv $ZTNPnumber $ZTNP1 process Non-maintenance Telserv $ZTN number $ZTN0 process...
  • Page 70: Hpe Integrity Nonstop X Ns7 Cg Systems

    HPE Integrity NonStop X NS7 CG Systems The NonStop X NS7 carrier-grade (CG) system which is used in Central Office and telecommunication environments uses a seismic rack with DC input power along with NS7 CG Standard and Optional Hardware on page 73. A system configuration is shown in the illustration that follows the tables.
  • Page 71 ESS support through HPE XP 7 Storage Array and HPE XP P9500 Storage Array Storage CLIMs Maintenance LAN Redundant configuration only Minimum NonStop System Consoles for fault-tolerance Connection to NonStop X Supported Cluster Solution HPE Integrity NonStop X NS7 CG Systems...
  • Page 72: Nebs Required Statements

    Use a ground cable of the same or larger size than the largest DC input power conductors, using a 40º C correction factor. ◦ Use a cable constructed of copper, 75° C minimum rated. ◦ Use only Listed two-hole copper compression-type lugs for the ground connector. HPE Integrity NonStop X NS7 CG Systems...
  • Page 73: Ns7 Cg Standard And Optional Hardware

    The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring. ESD warning label This symbol indicates Hewlett Packard Enterprise systems and peripherals that contain assemblies and components that are sensitive to electrostatic discharge (ESD). Carefully observe the precautions and recommended procedures in this document to prevent component damage from static electricity.
  • Page 74: Nonstop X Server Blade For Ns7 Cg Systems

    SAS Disk Enclosure CG The SAS disk enclosure CG provides the storage capacity for the Storage CLIM CG. This enclosure holds 24 2.5” SAS common carrier or universal carrier drive with redundant power and cooling. HPE Integrity NonStop X NS7 CG Systems...
  • Page 75 Gen10 Storage CLIM NC. NOTE: Also supported on Gen9 CLIM CG with appropriate SPRs. Figure 15: MSA2050 and P2000 G4 (DC power) HPE Integrity NonStop X NS7 CG Systems...
  • Page 76: Maintenance Switch Cg

    The breaker panel has two sides: A and B, which are electrically independent. Power cabling is accessed from the rear of the rack. You must order the breakers for all products, except the c7000 enclosure. HPE Integrity NonStop X NS7 CG Systems...
  • Page 77 4 (maximum 50A rating) outputs per power rail connect to other CG components CAUTION: Outputs 4-7 are not rated for 80A breakers. Do not install 80A breakers in these outputs Maximum 240A output load Nominal input voltage -48/-60 VDC Table Continued HPE Integrity NonStop X NS7 CG Systems...
  • Page 78: Hpe Nonstop 80A Fuse Panel Cg

    HPE NonStop 80A Fuse Panel CG NOTE: The descriptions in this manual are provided for reference only. For your safety, only authorized Hewlett Packard Enterprise service providers can work with the fuse panel and other DC power components. The dual-input, 80A fuse panel provides power protection for the NS7 CG components. The fuse panel has two sides: A and B, which are electrically independent, distributing power to four individually fused TPA outputs (rated 50A) per rail and to five individually fused GMT outputs (rated 15A) per rail.
  • Page 79: Hpe Nonstop Ns7 Cg System Alarm Panel

    A serious disruption of service, a malfunction, or a FRU failure has occurred. Immediate corrective action is required. Minor A non-service-affecting condition has occurred. This alarm does not require immediate corrective action. Power A power fault has occurred. Idle No alarms are active. HPE Integrity NonStop X NS7 CG Systems...
  • Page 80: System Installation Specifications For Ns7 Cg Systems

    System Installation Specifications for NS7 CG Systems This chapter provides specifications necessary for planning the installation of NS7 CG systems. DC Power Distribution for NS7 CG Systems Examples of NS7 CG Power Distributions NS7 CG Component Branch Circuit Protection Per Rail c7000 CG enclosure 3 x 80A CLIM CG or CLIM NC...
  • Page 81: Ns7 Cg Enclosure Power Loads

    NS7 CG Component Branch Circuit Protection Per Rail c7000 CG enclosure 3 x 80A CLIM CG or CLIM NC CG SAS disk enclosure or NC SAS disk enclosure CG Maintenance switch Alarm panel Fuse panel 100A (input rated) Breaker panel 300A (input rated) NS7 CG Enclosure Power Loads The total power and current load for a rack depends on the number and type of enclosures installed in it.
  • Page 82 Table 11: NS7 X3 CG Power Loads NS7 X3 CG Enclosure Power Lines per Typical Power Maximum Power Type Enclosure Consumption (VA) Consumption (VA) c7000 CG enclosure 2250 BL460c Gen10 CG CPU (64GB RAM) BL460c Gen10 CG CPU (128GB RAM) BL460c Gen10 CG CPU (256GB RAM) 64GB Memory kit...
  • Page 83 NS7 X3 CG Enclosure Power Lines per Typical Power Maximum Power Type Enclosure Consumption (VA) Consumption (VA) Deskside system console Deskside system Console monitor and keyboard Typical = measured at 22C ambient temp Maximum = measured at 35C ambient temp Table 12: NS7 X2 CG Power Loads NS7 X2 CG Enclosure Power Lines per...
  • Page 84: Dimensions And Weights Of Ns7 Cg Systems

    NS7 X2 CG Enclosure Power Lines per Typical Power Maximum Power Type Enclosure Consumption (VA) Consumption (VA) CG Maintenance switch (Ethernet) Breaker panel Fuse panel Alarm panel Rack-mount system console (must be installed in separate rack) Console keyboard and monitor Deskside system console Deskside system Console monitor...
  • Page 85: Unit Sizes For Ns7 Cg Systems

    Service Clearance and Floor Space Requirements Measurement Minimum Recommended Front (appearance side) clearance 91.4 51.2 Rear (service side) clearance 91.4 51.2 Space between racks < 1.0 < 2.5 Rack pitch 68.6 Unpacking area: When moving the rack off the shipping pallet, you need approximately 9 feet (2.74 meters) on one side of the rack to allow you to slide the pallet out from under the rack after the rack has been raised on the casters.
  • Page 86: Enclosure Dimensions For Ns7 Cg Systems

    Enclosure Dimensions for NS7 CG Systems Enclosure Height Width Depth Type Fuse Panel 48.3 30.5 77.5 (including 63.5 safety cover) 25 (without safety cover) c7000 CG 17.4 44.2 17.5 44.5 36.7 93.3 enclosure CLIM CG 17.5 44.5 27.25 69.2 and CLIM NC, all models CLIM CG...
  • Page 87 Table 13: Rack Weight Worksheet for an NS7 X3 CG Weight Worksheet for Rack Number _____ Enclosure Type Number of Weight Total Enclosures Breaker panel 22.7 Fuse panel Alarm panel CG c7000 enclosure 146.5 BL460c Gen10 64GB BL460c Gen10 CPU 128GB BL460c Gen10 CPU 256GB...
  • Page 88 Table 14: Rack Weight Worksheet for an NS7 X2 CG Weight Worksheet for Rack Number _____ Enclosure Type Number of Weight Total Enclosures Breaker panel 22.7 Fuse panel Alarm panel CG c7000 enclosure 146.5 BL460c Gen9 64GB BL460c Gen9 CPU 128GB BL460c Gen9 CPU 192GB...
  • Page 89: Environmental Specifications For Ns7 Cg Systems

    Environmental Specifications for NS7 CG Systems Heat Dissipation Specification and Worksheets for NS7 CG Systems Table 15: Heat Dissipation Worksheet for NS7 CG X3 Seismic Rack Heat Dissipation Worksheet for Rack Number ______ Enclosure Type Number Typical Unit Heat Maximum Unit Heat Total (BTU/hour) Installed (BTU/hour)
  • Page 90 Heat Dissipation Worksheet for Rack Number ______ Enclosure Type Number Typical Unit Heat Maximum Unit Heat Total (BTU/hour) Installed (BTU/hour) (BTU/hour) SAS 2.5 in disk drive 300 GB, 15k CG Maintenance switch Enclosure Type Number Unit Heat (Btu/hour Unit Heat (Btu/hour Installed with one line with both lines...
  • Page 91 Heat Dissipation Worksheet for Rack Number ______ Enclosure Type Number Typical Unit Heat Maximum Unit Heat Total (BTU/hour) Installed (BTU/hour) (BTU/hour) BL460c Gen9 1126 1126 server blade, 192GB BL460c Gen9 server blade, memory kit Gen9 Storage CLIM CG Gen9 10GbE Networking CLIM 4C/1C Gen9 10GbE...
  • Page 92: Operating Temperature, Humidity, And Altitude

    Site cables and lugs must be provided by the customer or the installation provider for the customer. Hewlett Packard Enterprise does not provide these items to the customer. IMPORTANT: The power cables should be assembled by a certified electrician only.
  • Page 93 CAUTION: Use Table 310.16 or Table 310.18 along with Table 310.15(B)(2)(a). See Required Documentation on page 92 to verify the site power input cables meet the ampacity requirements for a NEBS 50°C environment. To ensure the site power input cables you plan to use meet the ampacity requirements for a NEBS 50°C environment: •...
  • Page 94: Websites

    Websites General websites Hewlett Packard Enterprise Information Library www.hpe.com/info/EIL Single Point of Connectivity Knowledge (SPOCK) Storage compatibility matrix www.hpe.com/storage/spock Storage white papers and analyst reports www.hpe.com/storage/whitepapers For additional websites, see Support and other resources. NonStop websites NonStop Technical Library http://www.hpe.com/info/nonstop-docs HPE NonStop eServices Portal https://h22204.www2.hpe.com/NEP...
  • Page 95: Support And Other Resources

    Accessing Hewlett Packard Enterprise Support • For live assistance, go to the Contact Hewlett Packard Enterprise Worldwide website: http://www.hpe.com/assistance • To access documentation and support services, go to the Hewlett Packard Enterprise Support Center website: http://www.hpe.com/support/hpesc Information to collect •...
  • Page 96: Customer Self Repair

    Customer self repair Hewlett Packard Enterprise customer self repair (CSR) programs allow you to repair your product. If a CSR part needs to be replaced, it will be shipped directly to you so that you can install it at your convenience.
  • Page 97: Regulatory Information

    Documentation feedback Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hpe.com). When submitting your feedback, include the document title, part number, edition, and publication date located on the front cover of the document.
  • Page 98: Cables

    Cables Cable Types and Connectors Although a considerable cable length can exist between the modular enclosures in the system, Hewlett Packard Enterprise recommends that cable length between each of the enclosures be as short as possible. The following table lists the available cables. For specific connections, see your system Technical Document as described in Technical Document for NS7 Systems on page 26.
  • Page 99: Ups And Data Center Power Configurations

    NonStop platforms and can be used with single-phase and three- phase UPS. IMPORTANT: You must change the ride-through time for a Hewlett Packard Enterprise-supported UPS from the manufacturing default setting to an appropriate value for your system. During installation of an NS7 or HPE UPS, your service provider can refer to the "Setting the Ride-Through...
  • Page 100: Ns7 System With A Rack-Mounted Ups

    Figure 16: NS7 System With a Fault-Tolerant Data Center NS7 System With a Rack-Mounted UPS Figure 17: NS7 System With a Rack-Mounted UPS on page 101 shows an example of a supported configuration in a NS7 system with the left PDUs connected to one or more rack-mounted UPS and the right PDUs connected directly to the utility power.
  • Page 101 Figure 17: NS7 System With a Rack-Mounted UPS When OSM detects that one power rail is running on UPS and the other power rail has lost power, OSM logs an event indicating the beginning of the configured ride-through time period. OSM monitors if AC power is restored before the ride-through period ends.
  • Page 102: Sas Disk Enclosures With A Rack-Mounted Ups

    SAS Disk Enclosures With a Rack-Mounted UPS In this supported configuration, only SAS Disk Enclosures are protected by the rack-mounted UPS. The rack(s) with SAS Disk Enclosures and/or Storage CLIMs are supported by one or more rack-mounted UPS. Figure 18: SAS Disk Enclosures With a Rack-Mounted UPS on page 102 shows an example of this supported configuration in a NS7 system with the left PDUs connected to the rack-mounted UPS and the right PDUs connected to the utility power.
  • Page 103: Non-Supported Ups Configurations

    Non-Supported UPS Configurations This section identifies non-supported UPS configurations and explains why these configurations are not supported. It also explains what you must do to prevent data loss. CAUTION: If disk drive write caching is enabled in the NS7 system, do not use any of these non- supported UPS configurations.
  • Page 104 Figure 19: NS7 System With a Data Center UPS, Single Power Rail When the utility power fails, OSM does not detect that the data center UPS is running on battery and the UPS has entered its battery runtime. OSM does not initiate the controlled shutdown of the I/O operations and processors.
  • Page 105: Ns7 System With Data Center Ups, Both Power Rails

    • When the utility power is restored, you can enable the WCE. • During the utility power failure, the system can continue to run until the data center UPS runs out of power or until it shuts down. NS7 System With Data Center UPS, Both Power Rails In this non-supported configuration, a NS7 system is installed in a Tier-I, Tier-II or Tier-III data center.
  • Page 106 Figure 20: NS7 System With Data Center UPS, Both Power Rails When the utility power fails, OSM does not detect that the data center UPS is running on battery and the UPS has entered its battery runtime. OSM does not initiate the controlled shutdown of the I/O operations and processors.
  • Page 107: Ns7 System With Rack-Mounted Ups And Data Center Ups In Parallel

    • When the utility power is restored, you can enable WCE. • During a utility power failure, the system can continue to run until the data center UPS runs out of power or until it shuts down. NS7 System With Rack-Mounted UPS and Data Center UPS in Parallel Figure 21: NS7 System With Rack-Mounted UPS and Data Center UPS in Parallel on page 107 shows an example of a non-supported configuration in a NS7 system with the left PDUs connected to the rack-mounted UPS and the right PDUs connected to the data center UPS.
  • Page 108: Ns7 System With Two Rack-Mounted Ups In Parallel

    UPS is running on battery and that the UPS has entered its battery runtime. OSM does not initiate the controlled shutdown of the I/O operations and processors. • The rack-mounted UPS shuts down before the data center UPS. • If the utility power is not restored before the data center UPS shuts down, any data in the NS7 system disk drive write cache that has not been transferred to the disk drive media is lost.
  • Page 109 If the utility power is not restored before both rack-mounted UPSs shut down, any data in the NS7 system disk drive write cache that has not been transferred to the disk drive media is lost. If you want to extend the UPS battery runtime, Hewlett Packard Enterprise recommends adding Extended Runtime Modules (ERMs) to the UPS.
  • Page 110: Ns7 System With Cascading Rack-Mounted Ups And Data Center Ups

    NS7 System With Cascading Rack-Mounted UPS and Data Center UPS Figure 23: NS7 System With Cascading UPS on page 110 shows an example of a non-supported configuration in a NS7 system with the left PDUs connected to the rack-mounted UPS and the right PDUs connected to a data center UPS.
  • Page 111 To ensure correct UPS function, Hewlett Packard Enterprise recommends that you conduct on-site system testing and that you try to use the supported UPS configurations described in this appendix.
  • Page 112: Power Distribution Unit (Pdu) Types For An Enterprise Series Rack

    Power Distribution Unit (PDU) Types for an Enterprise Series Rack The Enterprise series rack (formerly known as the Intelligent rack) supports Intelligent PDUs (iPDUs) and Modular PDUs. Both PDU types use a core and extension bar design with these characteristics: •...
  • Page 113: Four Intelligent Pdus Without Ups - (Na/Jpn And Intl, Single-Phase And Three-Phase)

    Supported PDU Examples of Configurations Types Configurations Four PDU cores with UPS Four Modular PDUs With Single-Phase UPS (NA/JPN and INTL) on page 120 Four Modular PDUs With Three-Phase UPS (NA/JPN and INTL) on page 119 Two PDU cores without UPS Two Modular PDUs Without UPS —...
  • Page 114: Four Intelligent Pdus With Single-Phase Ups - (Na/Jpn And Intl)

    Figure 24: Four iPDUs Without UPS — (NA/JPN and INTL, Single-Phase and Three-Phase) Four Intelligent PDUs With Single-Phase UPS – (NA/JPN and INTL) This illustration shows the power configuration for four iPDUs and two single-phase UPS's in a rack. For detailed power specifications and connector types, see AC Input Power for NS7 Racks.
  • Page 115: Four Intelligent Pdus With Three-Phase Ups (Na/Jpn And Intl)

    Figure 25: Four iPDUs With Single-Phase UPS — (NA/JPN and INTL) Four Intelligent PDUs With Three-Phase UPS (NA/JPN and INTL) This illustration shows the power configuration for four iPDUs and a three-phase UPS in a rack. For detailed power specifications and connector types, see AC Input Power for NS7 Racks.
  • Page 116: Two Intelligent Pdus Without Ups - (Na/Jpn And Intl, Single-Phase And Three-Phase)

    Figure 26: Four iPDUs With Three-Phase UPS — (NA/JPN and INTL) Two Intelligent PDUs Without UPS — (NA/JPN and INTL, Single-Phase and Three-Phase) This illustration shows the connections for two iPDUs in a rack without a UPS. For detailed power specifications and connector types, see AC Input Power for Enterprise Series and Intelligent Racks on page 125.
  • Page 117: Two Intelligent Pdus With Single-Phase Ups - (Na/Jpn And Intl)

    Figure 27: Two Intelligent PDUs Without UPS— (NA/JPN and INTL, Single-Phase and Three-Phase) Two Intelligent PDUs With Single-Phase UPS — (NA/JPN and INTL) This illustration shows the power configuration for two iPDUs and a single-phase UPS in a rack. For detailed power specifications and connector types, see AC Input Power for NS7 Racks.
  • Page 118: Two Intelligent Pdus With Three-Phase Ups - (Na/Jpn And Intl)

    Figure 28: Two Intelligent PDUs With Single-Phase — (NA/JPN and INTL) Two Intelligent PDUs With Three-Phase UPS — (NA/JPN and INTL) This illustration shows the power configuration for two iPDUs and a three-phase UPS in a rack. For detailed power specifications and connector types, see AC Input Power for NS7 Racks.
  • Page 119: Four Modular Pdus With Three-Phase Ups (Na/Jpn And Intl)

    Figure 29: Two Intelligent PDUs With Three-Phase UPS — (NA/JPN and INTL) Four Modular PDUs With Three-Phase UPS (NA/JPN and INTL) This illustration shows the power configuration for four modular PDUs and a three-phase UPS in a rack. For detailed power specifications and connector types, see AC Input Power for NS7 Racks.
  • Page 120: Four Modular Pdus With Single-Phase Ups (Na/Jpn And Intl)

    Figure 30: Four Modular PDUs With Three-Phase UPS — (NA/JPN and INTL) Four Modular PDUs With Single-Phase UPS (NA/JPN and INTL) This illustration shows the power configuration for four modular PDUs and two single-phase UPS's in a rack. For detailed power specifications and connector types, see AC Input Power for NS7 Racks.
  • Page 121: Four Modular Pdus Without Ups - (Na And Jpn, Single-Phase And Three-Phase)

    Figure 31: Four Modular PDUs With Single-Phase UPS — (NA/JPN and INTL) Four Modular PDUs Without UPS — (NA and JPN, Single- Phase and Three-Phase) This illustration shows the power configuration for four modular PDUs in a rack without a UPS. For detailed power specifications and connector types, see AC Input Power for NS7 Racks.
  • Page 122: Two Modular Pdus Without Ups - (Na/Jpn And Intl, Single-Phase And Three-Phase)

    Figure 32: Four Modular PDUs Without UPS — (NA/JPN and INTL, Single-Phase and Three-Phase) Two Modular PDUs Without UPS — (NA/JPN and INTL, Single-Phase and Three-Phase) This illustration shows the power configuration for two modular PDUs without a UPS in a rack. For detailed power specifications and connector types, see AC Input Power for NS7 Racks.
  • Page 123: Two Modular Pdu Connections With Single-Phase Ups - (Na/Jpn And Intl)

    Figure 33: Two Modular PDUs Without UPS — (NA/JPN and INTL, Single-Phase and Three-Phase) Two Modular PDU Connections With Single-Phase UPS — (NA/JPN and INTL) This illustration shows the connections for two modular PDUs with a single-phase UPS in a rack. For detailed power specifications and connector types, see AC Input Power for NS7 Racks.
  • Page 124: Two Modular Pdu Connections With Three-Phase Ups - (Na/Jpn And Intl)

    Figure 34: Two Modular PDUs With a Single-Phase UPS — (NA/JPN and INTL) Two Modular PDU Connections With Three-Phase UPS — (NA/JPN and INTL) This illustration shows the connections for two modular PDUs with a three-phase UPS in a rack. For detailed power specifications and connector types, see AC Input Power for NS7 Racks.
  • Page 125: Ac Input Power For Enterprise Series And Intelligent Racks

    Figure 35: Two Modular PDUs With a Three-Phase UPS — (NA/JPN and INTL) AC Input Power for Enterprise Series and Intelligent Racks Power Specifications...
  • Page 126 Region Phase See... North America/ Single-Phase Japan Three-Phase International Single-Phase Three-Phase CAUTION: Be sure the hardware configuration and resultant power loads of each rack within the system do not exceed the capacity of the branch circuit according to applicable electrical codes and regulations.
  • Page 127 Table 18: North America/Japan Three-Phase Power Specifications North America/Japan R12000 3-phase UPS iPDU 3-phase Modular PDU 3-phase Output Load 12 kW 24 A 24 A Input Voltage 208V 3P Wye 208V 3P Delta 208V 3P Delta Input Connector IEC309 560P9 NEMA L15-30P NEMA L15-30P Output Voltage...
  • Page 128: Enclosure Ac Input For The Enterprise Series Or Intelligent Rack

    Table 20: International Three-Phase Power Specifications International R12000 3-phase UPS iPDU 3-phase Modular PDU 3-phase Output Load 12 kW 16 A/phase 16 A/phase Input Voltage 380-415V 3P Wye 380-415V 3P Wye 380-415V 3P Wye Input Connector IEC309 532P6 IEC309 516P6 IEC309 516P6 Output Voltage 400V 3P Wye...
  • Page 129 Specification Value Voltage range 200-240 VAC Nominal line frequency 50 or 60 Hz Frequency ranges 47-53 Hz or 57-63 Hz Number of phases...
  • Page 130: Warranty Information

    HPE Storage Products www.hpe.com/support/Storage-Warranties HPE Networking Products www.hpe.com/support/Networking-Warranties Belarus Kazakhstan Russia marking Manufacturer and Local Representative Information Manufacturer information: Hewlett Packard Enterprise Company, 3000 Hanover Street, Palo Alto, CA 94304 U.S. Local representative information Russian: • Russia: • Belarus: •...
  • Page 131: Turkey Rohs Material Content Declaration

    • Kazakhstan: Manufacturing date: The manufacturing date is defined by the serial number. CCSYWWZZZZ (serial number format for this product) Valid date formats include: • YWW, where Y indicates the year counting from within each new decade, with 2000 as the starting point;...

Table of Contents