7. TROUBLESHOOTING

pROBLEM
excessive dust cloud in the cabinet.
Uneven blasting.
Inadequate speed or efficiency of blast.
Static electricity.
Blast pattern too wide or ineffective.
ENVIRONMENT pROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business park, Bury St Edmunds, Suffolk. Ip32 7AR
01284 757500
© Jack Sealey limited
pOSSIBLE CAUSE
1. exhaust vent or air flow is blocked.
2. Abrasive is worn.
3. Too much abrasive in the cabinet
4. loose air line or fittings.
1. Too much abrasive in cabinet.
2. Moisture inside cabinet.
1. Abrasive is worn.
2. Pressure is too low.
1. dry weather conditions.
1. nozzle blocked or worn.
01284 703534
sales@sealey.co.uk
Original Language Version
REMEDy
1. Clean vent and keep vent away from any wall.
Connect to a suitable dust extraction system.
2. Replace.
3. Remove excess with a type "H" vacuum cleaner.
4. Check and tighten all air fittings.
1. Remove excess with a type "H" vacuum cleaner.
2. Check air line for moisture.
1. Replace.
2. Check that there are no supply blockages or leaks.
Increase pressure. Max:90psi
1. leave the workpiece to stand for a while.
1. Unblock or replace nozzle
www.sealey.co.uk