Motor Lubrication - Ingersoll-Rand EP 20 SE Operators/Instruction Manual Options

Rotary screw air compressor
Table of Contents

Advertisement

5.15 MOTOR LUBRICATION

The induction-type squirrel cage motors have antifriction
ball or roller bearings front and rear. At periodic intervals
they require relubrication.
Relubrication Interval
(or 9 months, whichever comes first)
1000 hours ......................................all TEFC drive motors
2000 hours .........all ODP drive motors and all fan motors
Relubrication amount
Motor Frame Size
254-286
324-365
Improper lubrication can be a cause of motor bearing
failure. The quantity of grease added should be carefully
controlled. The smaller motors must be greased with a
lesser amount of grease than larger motors.
!
CAUTION
Overgreasing can be a cause of bearing and
motor failure. Make sure dirt and contaminants
are not introduced when adding grease.
Procedure for relubrication
!
CAUTION
Grease should be added when the motor
is stopped and power disconnected.
When regreasing, stop motor. Disconnect power; lock out
and tag. Remove outlet plugs (or spring-loaded grease
relief plugs if present). The outlet plug may not be
accessible on the fan end of some TEFC motors.
Lubricant Amount
in
cc
oz.
grams
3
1.0
16
.8
1.5
25
1.2
23
34
Motors MUST be greased
periodically. See Operators
Manual for procedure.
NOTICE
39570098
39